HomeMy WebLinkAboutA611.pdfTILE. REFER TO FINISH SCHEDULE
FOR SPECIFICATIONS
1:20 PITCH MAX.
WOOD FLOOR -
REFER TO FINISH SCHEDULE
FOR SPECIFICATIONS
GC TO FEATHER SETTING
COMPOUND TO ALIGN WITH TOP
OF WOOD AS SHOWN
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
3/8"
3/4"
G.C. TO INSTALL 3/4" HIGH
SCHLUTER SCHIENE STRIP
(AE200)
G.C. TO INSTALL 9/16" HIGH
SCHLUTER SCHIENE STRIP
(AE150) WHERE 9/16" THICK
WOOD FLOORING IS
PROPOSED.
WOOD FLOOR -
REFER TO FINISH SCHEDULE
FOR SPECIFICATIONS
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
WOOD FLOOR -
REFER TO FINISH
SCHEDULE FOR
SPECIFICATIONS
G.C. TO INSTALL 3/4" HIGH
SCHLUTER SCHIENE STRIP
(AE200)
3/4"
G.C. TO INSTALL 9/16" HIGH
SCHLUTER SCHIENE STRIP
(AE150) WHERE 9/16" THICK
WOOD FLOORING IS
PROPOSED.
EXISTING TILE
G.C. TO INSTALL 1/2" HIGH
SCHLUTER SCHIENE STRIP
(AE125)
1/2"
TILE. REFER TO FINISH
SCHEDULE FOR
SPECIFICATIONS
1:20 PITCH MAX.
GC TO FEATHER SETTING
COMPOUND TO ALIGN WITH TOP
OF COCO MAT. AS SHOWN
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
WALK-OFF MAT. REFER TO
FINISH SCHEDULE FOR
SPECIFICATIONS, 1:20 PITCH
MAX.
1/8"
3/8"
SHOWER ENCLOSURE BEYOND
TILE ON SETTING BED
WHITE MARBLE THRESHOLD
TILE ON SETTING BED
FLOOR LEVELING COMPOUND
- FEATHER FOR FLUSH
TRANSITION SLOPE 1/16" PER
FOOT MAX.
RESTROOM
1/2" 1/2"
2" 1/4"
1/4" MAX
1/2"
CONCRETE SLAB
SHOWER
WATERPROOF MEMBRANE
(E) CONCRETE
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
MARBLE THRESHOLD (O.A.E.)
AT DOOR LOCATION.
GC TO VERIFY HEIGHTS IN
FIELD PRIOR TO FURNISH
AND INSTALLATION.
PER WALL TYPE
DOOR TO HAVE 1"
UNDERCUT AS REQUIRED BY
M110
STORESIDE EGRESS CORRIDOR
ALIGN EDGE OF TRANSITION
WITH DOOR. TRANSITION NOT
BE SEEN FROM SALES FLOOR.
SEALED RUBBER - REFER TO
FINISH SCHEDULE FOR
SPECIFICATIONS
GC TO FEATHER UP SUB
FLOORING TO CREATE EVEN
TRANSITION TO THRESHOLD.
1:20 PITCH MAX.
1/4"
1/4"
1/4"
1/4"
2"
TILE TO MATCH EXISTING MALL
TILE PER GC GC TO FEATHER
COMPOUND TO ALIGN WITH TOP
OF WOOD AS REQ'D.
ALIGN EDGE OF TRANSITION
WITH DOOR. TRANSITION NOT
TO BE SEEN FROM SALES
FLOOR.
WOOD FLOOR-REFER TO
FINISH SCHEDULE FOR
SPECIFICATIONS.
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
FLUSH THRESHOLD AT DOOR
LOCATION. SEE DOOR
HARDWARE SCHEDULE FOR
SPECIFICATION. GC TO VERIFY
HEIGHTS IN FIELD PRIOR TO
FURNISH AND INSTALLATION.
3/4"
STORESIDE MALL CORRIDOR
10"
WOOD FLOOR TO CONTINUE
TO EDGE OF DOOR. REFER
TO FINISH SCHEDULE FOR
SPECIFICATIONS
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED. VERIFY
IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
ALIGN EDGE OF TRANSITION
WITH DOOR. TRANSITION NOT
BE SEEN FROM SALES FLOOR.
SEALED RUBBER - REFER TO
FINISH SCHEDULE FOR
SPECIFICATIONS
GC TO FEATHER UP SUB
FLOORING TO CREATE EVEN
TRANSITION TO THRESHOLD.
1:20 PITCH MAX.
MARBLE THRESHOLD (O.A.E.)
AT DOOR LOCATION. GC TO
VERIFY HEIGHTS IN FIELD PRIOR
TO FURNISH AND INSTALLATION.
1/8"
3/4"
PER WALL TYPE
2"
1/4"
1/4"
3/8" TILE
REFER TO FINISH SCHEDULE
FOR SPECIFICATIONS
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
MARBLE THRESHOLD (O.A.E.)
AT DOOR LOCATION.
GC TO VERIFY HEIGHTS IN
FIELD PRIOR TO FURNISH
AND INSTALLATION.
1 7/8"
PER WALL TYPE
3/4"
DOOR TO HAVE 1"
UNDERCUT AS REQUIRED BY
M110
WOOD FLOOR -
REFER TO FINISH SCHEDULE
FOR SPECIFICATIONS
1/8"
3/8"
1/4"
1/4" TILE, REFER TO SCHEDULE FOR
SPECIFICATIONS
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING,
TYP.
ALIGN EDGE OF TRANSITION
WITH DOOR. TRANSITION NOT
BE SEEN FROM SALES FLOOR.
SEALED RUBBER, REFER TO
SCHEDULE FOR
SPECIFICATIONS
GC TO FEATHER UP SUB
FLOORING TO CREATE EVEN
TRANSITION TO THRESHOLD.
1:20 PITCH MAX.
MARBLE THRESHOLD (O.A.E.)
AT DOOR LOCATION. GC TO
VERIFY HEIGHTS IN FIELD PRIOR
TO FURNISH AND INSTALLATION.
DOOR TO HAVE 1" UNDERCUT
AS REQUIRED PER M110 1/8"
2"
PER WALL TYPE
1/8"
3/8"
1/4"
1/4" 1/4"
EXISTING CONCRETE SIDEWALK
TILE. REFER TO FINISH
SCHEDULE FOR
SPECIFICATIONS.
GC TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
VERIFY IN FIELD PRIOR TO
INSTALLATION OF FLOORING
(TYP.)
THRESHOLD PER DOOR
HARDWARE SCHEDULE. GC TO
VERIFY HEIGHTS IN FIELD
PRIOR TO FURNISH AND
INSTALLATION.
INSIDE OUTSIDE
10"
1/4" 1/4"
SIDEWALK SLOPE
1/4" : 12"
1/8"
3/8"
WALK-OFF MAT REFER
TO FINISH SCHEDULE
FOR SPECIFICATIONS.
SLOPE TO LEASE LINE.
OUTSIDE
INSIDE 10"
G.C. TO ENSURE A LEVEL
SUBFLOOR AS NEEDED.
1/2"
SIDEWALK SLOPE
1/8" : 12"
EXISTING CONCRETE SIDEWALK
THRESHOLD PER DOOR
HARDWARE SCHEDULE. GC
TO VERIFY HEIGHTS IN FIELD
PRIOR TO FURNISH AND
INSTALLATION.
1/4"
1/4"
A California Corporation
ARCHITECTURE
20521 EARL STREET
TORRANCE, CA 90503
T. 310-343-3430 | F. 310-343-3431
www.menemshasolutions.com
LOS ANGELES | BOSTON
Plans, maps, specifications, studies, and
reports not containing a red ink seal imprint
accompanied by an original signature by
the licensed professional may have been
fraudulently altered and shall not be
considered an original copy. All information
should be disregarded unless verified by
the professional whose signature appears
above. Copyright Protected 2012.
Architect:
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
A611
TYPICAL DOOR DETAILS
NA
BAB
193 GORE CREEK DRIVE
Vail, CO 81657 SCALE: 3" = 1'-0"
3
WOOD TO TILE TRANSITION @ ENTRY
SCALE: 3" = 1'-0"
4
WOOD TO WOOD TRANSITION
SCALE: 3" = 1'-0"
2
TILE TO MAT TRANSITION @ ENTRY
SCALE: 3" = 1'-0" 5
TILE TO THRESHOLD TRANSITION @ SHOWER
SCALE: 3" = 1'-0" 12
RUBBER TO CONC. THESHOLD TRANSITION
SCALE: 3" = 1'-0" 6
WOOD TO MALL TILE TRANSITION @ INTERIOR ENTRY
SCALE: 3" = 1'-0" 11
WOOD TO RUBBER TRANSITION
SCALE: 3" = 1'-0" 9
WOOD TO TILE TRANSITION @ TOILET
SCALE: 3" = 1'-0" 10
TILE TO RUBBER TRANSITION
SCALE: 3" = 1'-0"
7
TILE TO CONC. TRANSITION AT EXTERIOR ENTRY
DOOR
SCALE: 3" = 1'-0" 8
MAT TO CONC. TRANSITION AT EXTERIOR ENTRY
DOOR
SCALE: NTS
NOT USED
1
NO. DATE
DESCRIPTION
10/08/14