HomeMy WebLinkAboutA811.pdf8'-10"
T.O. FITTING
ROOM PANEL
T.O. FITTING
ROOM PANEL
SCALE: AS NOTED
ELEVATION B
SCALE: AS NOTED
ELEVATION D
8'-10"
SCALE: AS NOTED
ELEVATION E 4" 4'-2"
1'-8"
2'-6"
VERIFY
8'-10"
SLATWALL
W/ INSERT
SHELF
SHELF
B1
T.O. FITTING
ROOM PANEL
ELEVATION A
SCALE: AS NOTED
8'-10"
3'-4"
SCALE: AS NOTED
eLEVATION C
PUSH DOOR
FOR STORAGE
AREA ACCESS
B1
8'-10"
T.O. FITTING
ROOM PANEL
3'-6"
2'-0"
2'-6"
CEILING BEAMS
ABOVE
CEILING BEAMS
ABOVE
CEILING BEAMS
ABOVE
CEILING BEAMS
ABOVE
GENERAL NOTES
*REFER TO FINISH SCHEDULE & FIXTURE SCHEDULE FOR TAGGED
ELEMENTS
A811
A
B
C
STORAGE
(E)
SPRINKLER
PIPE
(E)
SPRINKLER
PIPE
A810
2
F.F.E
0"
U.S. CEILING
11' - 2 3/4"
GWB CEILING A.F.M
1' - 7 1/2"
10' - 5 1/4"
8'-1 1/2"
CEILING BEAMS
ABOVE
(E)
SPRINKLER
PIPE
B.O. PIPE
9'-3 1/2"
FR-MI FR-SU FR-SU FR-SU F.F.E
0"
U.S. CEILING
11' - 2 3/4"
UPPER LEVEL
1' - 7 1/4"
6" 6'-7"
9' - 8 3/4"
*SW-SON-48*
8'-1 1/2"
CEILING BEAMS
ABOVE
B.O. PIPE
8'-6"
(E) SPRINKLER
PIPE
*FR-SU* F.F.E
0"
U.S. CEILING
11' - 2 3/4"
UPPER LEVEL
1' - 7 1/4"
10' - 5 1/4"
8'-10"
CEILING BEAMS
ABOVE
(E) SPRINKLER
PIPE
B.O. PIPE
8'-6"
FR-ADA FR-MI
STORAGE
3
A811
B
C
D
A
SLAT WALL
W/ INSERT
3
A811
E
4'-0"
1'-0 1/2" 2'-0 1/4" 11 3/4"
3'-5 3/4"
A California Corporation
ARCHITECTURE
20521 EARL STREET
TORRANCE, CA 90503
T. 310-343-3430 | F. 310-343-3431
www.menemshasolutions.com
LOS ANGELES | BOSTON
Plans, maps, specifications, studies, and
reports not containing a red ink seal imprint
accompanied by an original signature by
the licensed professional may have been
fraudulently altered and shall not be
considered an original copy. All information
should be disregarded unless verified by
the professional whose signature appears
above. Copyright Protected 2012.
Architect:
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
A811
PROJ SPEC ENLRGD FITRM PLN & ELEV
NA
BAB
193 GORE CREEK DRIVE
Vail, CO 81657 SCALE: 1/4" = 1'-0" 3
CUSTOM FITTING ROOM W/ STORAGE DOOR ELEVATION
A ALL QUANTITIES SHOULD BE VERIFIED BY FIXTURE VENDOR. PRIOR TO ORDERING AND
INSTALLATION. G.C. TO CHECK ALL QUANTITIES OF MILLWORK UPON DELIVERY.
B ALL WOODWORK ATTACHED TO THE PREMISES, BLOCKING, GROUNDS, ETC...SHALL BE FIRE
RETARDANT AND COMPLY WITH THE LANDLORD'S FIREPROOF GOVERNING BUILDING CODE
REQUIREMENTS.
C THE CONTRACTOR SHALL VERIFY ALL DIMENSIONS AND CONDITIONS AT THE JOB SITE AND
NOTIFY OWNER'S CONSTRUCTION MANAGER AS TO ANY DISCREPANCIES IMMEDIATELY.
D ALL FITROOM MILLWORK HARDWARE TO BE FURNISHED BY OWNER AND INSTALLED BY G.C.
E MILLWORK IS TO BE HANDLED UNDER SEPARATE CONTRACT BY OWNER. G.C. TO COORDINATE
SCHEDULING WITH MILLWORK VENDOR. REFER TO RESPONSIBILITY SCHEDULE ON SHEET G002
FOR MORE INFORMATION.
F ALL MIRRORS SUPPLIED & INSTALLED BY G.C. U.N.O. INSTALLED W/ADHESIVE, NO CLIPS
G REFER TO FIXTURE VENDOR CUT SHEETS FOR ALL FINISHES.
SCALE: 1/4" = 1'-0"
1
FITTING ROOM KEY PLAN
SCALE: 1/4" = 1'-0" A
FITTING ROOM ELEV-A
SCALE: 1/4" = 1'-0" B
FITTING ROOM ELEV- B
SCALE: 1/4" = 1'-0"
C
FITTING ROOM ELEV- C
SCALE: 3/4" = 1'-0"
2
CUSTOM FITTING ROOM W/ EXTRA STORAGE DOOR
NO. DATE
DESCRIPTION
10/08/14