HomeMy WebLinkAboutG003.pdfBUILDING CODE SUMMARY ITEM ALLOWABLE ACTUAL ITEM ALLOWABLE ACTUAL CODES IMPLEMENTED: CODE (M) MERCANTILE SPRINKLERED SINGLE STORY NO SEPARATION REQUIREMENT USE GROUP OR OCCUPANCY CLASSIFICATION SECTION 309 CONSTRUCTION CLASSIFICATION SECTION 602 BUILDING AREA TABLE 503 ALLOWABLE INCREASE 506.3 MEANS OF EGRESS TABLE 1004.1.1 INTERIOR FINISHES CLASSIFICATIONS TABLE 803.9 STOCKROOM/SALES PARTITION TABLE 508.4 BUILDING HEIGHT TABLE 503 1611 S.F. "THE AREAS SPECIFIED IN TABLE 503 MAY BE TRIPLED IN ONE STORY BUILDINGS AND DOUBLED IN BUILDINGS MORE THAN ONE STORY IF THE BUILDING IS PROVIDED WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM THROUGHOUT. " THE EXISTING BUILDING IS TYPE: II-B 1 STORY REQUIRED NUMBER OF EXITS TABLE 1015.1 (1) REQUIRED 1611 S.F. OCCUPANT LOAD: SALES : 1358 S.F. / 30 S.F PER OCCUPANT = 46 OCCUPANTS STOCKROOM : 253 S.F. / 300 S.F. PER OCCUPANT = 1 OCCUPANTS TOTAL SQUARE FOOTAGE = 1611 S.F. TOTAL OCCUPANTS = 47 OCCUPANTS HIGH RISE NO COVERED MALL NO SPRINKLERED THE EXISTING BUILDING IS 100% SPRINKLERED AND ALL MODIFICATIONS FOR NEW DESIGNS WILL CONFORM. FIRE PROTECTION SYSTEMS - SPRINKLER SYSTEM SECTION 903 THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE CITY OF VAIL AND FIRE DEPARTMENTS FOR ALL FIRE ALARM SYSTEM REQUIREMENTS PRIOR TO THE WORK. FIRE PROTECTIVE SIGNALING & DETECTION SYSTEMS - FIRE ALARM CHAPTER 9 MIN. EGRESS SEPARATION 1015.2.1 GROUP MERCANTILE - NO CHANGE IN USE GROUP NUMBER OF EMPLOYEES MAXIMUM OF 5 EMPLOYEES IN STORE NO RATING BETWEEN SALES AND STOCKROOM PARTITION (1) EXISTING IN SALES AREA; THE EXISTING BUILDING IS SPRINKLERED THE CONTRACT DOCUMENTS SHALL CONTAIN SUFFICIENT INFORMATION TO DESCRIBE THE ARCHITECTURAL, FIRE PROTECTION, FIRE ALARM, ELECTRICAL, MECHANICAL, AND ENERGY CONSERVATION SYSTEMS. THIS INCLUDES ANY REQUIRED CALCULATIONS, NARRATIVES, AND REPORTS DEEMED NECESSARY BY THE AUTHORITIES HAVING JURISDICTION. ENGINEERING DETAILS, REPORTS, CALCULATIONS, PLANS, & SPECIFICATIONS MAX. EGRESS PATH TABLE 1016.1 SHALL NOT EXCEED 250' WITH SPRINKLERS SIGN AT EXIT DOOR CHAPTER 10 EGRESS THROUGH THE STOCK ROOM SECTION 1014.2 EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES. EXCEPTION: MEANS OF EGRESS IS ALLOWED THROUGH STOCKROOMS WHERE ALL THE FOLLOWING ARE MET: STOCK IS SAME HAZARD CLASSIFICATION AS MAIN RETAIL AREA, NOT MORE THAN 50% EXIT ACCESS IS THROUGH STOCKROOM, STOCKROOM CANNOT BE LOCKED FROM EGRESS SIDE, AND THERE IS A DEMARCATED MINIMUM 44" WIDE AISLE DEFINED BY FULL OR PARTIAL HEIGHT FIXED WALLS OR SIMILAR CONSTRUCTION THAT WILL MAINTAIN REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS." HANDICAP ACCESSIBILITY MINIMUM PLUMBING FIXTURES EGRESS PATH APPROX. 74'-0" (FROM MIDPOINT OF PATH OF EGRESS TO EXIT) THE EXIT SIGNS MUST CONFORM WITH SECTION 1011.0 OVERALL DIAGONAL = N/A OVERALL 1/3 DIAGONAL = N/A DOOR TO DOOR DISTANCE = N/A THIS BUILDING AND SPACE SHALL CONFORM TO THE REQUIREMENTS AND REGULATIONS OF INTERNATIONAL BUILDING CODE FITTING ROOM REQUIREMENTS: SEAT/BENCH SHALL BE 24" BY 48" AND FIXED TO THE WALL ALONG THE SHORTER DIMENSION. CODE: CLEAR FLOOR SPACE SHALL BE PROVIDED ALONGSIDE THE BENCH TO ALLOW A PERSON USING A WHEELCHAIR TO MAKE A PARALLEL TRANSFER ONTO THE SEAT 2012 IMC 2012 IBC 2012 IPC 2012 IECC 2012 IFC 2012 IBC CITY OF VAIL 75 S FRONTAGE ROAD, VAIL, CO, 81657 PHONE: 970 479 2128 MECHANICAL ACCESSIBILITY PLUMBING ELECTRICAL FIRE/LIFE SAFETY CODE BUILDING DEPARTMENT TABLE 2902.1 MIN. FACILITIES FOR BLDG. OCCUP. NOTES: 1. DISTANCE FROM STOREFRONT TO CORE TOILET FACILITY IS 82'-0". 2. EGRESS PLAN FOR CODE PURPOSES ONLY. REFER TO A110 FOR CONSTRUCTION PLANS & NOTES. 3. FIRE EXTINGUISHER MOUNTED AT 3’-6” ABOVE FLOOR MAX.TRAVEL DISTANCE BETWEEN FIRE EXTINGUISHER – 75 FT. 2 WATER CLOSETS, 1 MALE/ 1 FEMALE 2 LAVATORIES, 1 MALE/ 1 FEMALE 1 DRINKING FOUNTAIN 1 SERVICE SIINK 2 TOILETS (EXISTING) 2 LAVATORY PROVIDED 1 DRINKING FOUNTAIN - IN LIEU OF DRINKING FOUNTAIN A SIGNATURE SINK /WATER FEATURE IS TO BE PROVIDED ACCESSIBLE TO THE PUBLIC - SEE A822 1 SERVICE (EXISTING) ENCLOSED VERTICAL EXITS & PASSAGEWAYS - CLASS B CORRIDORS PROVIDING EXIT ACCESS - CLASS C ROOMS OR ENCLOSED SPACES - CLASS C WHERE TWO EXIT DOORS ARE REQUIRED THE EXITS SHALL BE PLACED A DISTANCE APART EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL DIMENSION OF THE BUILDING AREA TO BE SERVED. EXCEPTION: IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM, THE SEPARATION DISTANCE OF THE EXIT DOORS SHALL NOT BE LESS THAN 1/3 OF THE THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL. EGRESS SUMMARY LEGEND NUMBER OF EXITS: 1 EGRESS SEPARATIONS: NA ALLOWED PATH OF TRAVEL (SPRINKLERED) TO ALL EGRESS (SPRINKLERED): 72'-4 1/2" 74 FE EXIT SIGN - SALES ONLY EX1 FIRE EXTINGUISHER EX3 EMERGENCY LIGHT F4EM EMERGENCY LIGHT - BOH EXIT SIGN - NON SALES EX2 F8EM EMERGENCY LIGHT - BOH BUILDING A B C D 2 1 OVER ALL DIAGONAL 72'-4 1/2" PATH OF EGRESS PATH OF EGRESS PATH OF EGRESS P ATH OF E G R E S S 3'-8" 3'-8" 3'-8" 3'-8" 3'-8" WATER FEATURE ELEMENT ACCESSIBLE, DESIGNED TO COMPLY W/ DRINKING FOUNTAIN REQUIREMENTS EX1 EX2 REZA A. HADAEGH 402807 S T A T E O F C O L O R A D O L I C E N S E D A R C H I T E C T Scale: Job Number: Drawing: LULULEMON ATHLETICA CONSTRUCTION STANDARDS Checked By: Drawn By: Date: ISSUED FOR DD-LLL xx/xx/xx ISSUED FOR DD-LLD ISSUED FOR CD-LLL 07/31/14 ISSUED FOR CD-LLD 08/14/14 ISSUED FOR PERMIT 08/15/14 ISSUED FOR BID xx/xx/xx ISSUED FOR SD NA 07/03/14 19780 08/15/14 G003 BLDG. CODE SUMMARY & EGRESS PLAN NA BAB 193 EAST GORE CREEK PLAZA Vail, CO 81657 SCALE: 3/16" = 1'-0" 1 EGRESS PLAN TRUE NORTH NO. DATE DESCRIPTION 10/08/14