HomeMy WebLinkAboutG003.pdfBUILDING CODE SUMMARY
ITEM ALLOWABLE ACTUAL ITEM ALLOWABLE ACTUAL
CODES IMPLEMENTED:
CODE
(M) MERCANTILE SPRINKLERED
SINGLE STORY
NO SEPARATION REQUIREMENT
USE GROUP OR OCCUPANCY
CLASSIFICATION SECTION 309
CONSTRUCTION CLASSIFICATION
SECTION 602
BUILDING AREA
TABLE 503
ALLOWABLE INCREASE 506.3
MEANS OF EGRESS
TABLE 1004.1.1
INTERIOR FINISHES
CLASSIFICATIONS
TABLE 803.9
STOCKROOM/SALES PARTITION
TABLE 508.4
BUILDING HEIGHT
TABLE 503
1611 S.F.
"THE AREAS SPECIFIED IN TABLE 503 MAY BE TRIPLED IN ONE STORY BUILDINGS
AND DOUBLED IN BUILDINGS MORE THAN ONE STORY IF THE BUILDING IS
PROVIDED WITH AN APPROVED AUTOMATIC SPRINKLER SYSTEM THROUGHOUT. "
THE EXISTING BUILDING IS TYPE: II-B
1 STORY
REQUIRED NUMBER OF EXITS
TABLE 1015.1
(1) REQUIRED
1611 S.F.
OCCUPANT LOAD:
SALES : 1358 S.F. / 30 S.F PER OCCUPANT = 46 OCCUPANTS
STOCKROOM : 253 S.F. / 300 S.F. PER OCCUPANT = 1 OCCUPANTS
TOTAL SQUARE FOOTAGE = 1611 S.F.
TOTAL OCCUPANTS = 47 OCCUPANTS
HIGH RISE
NO
COVERED MALL
NO
SPRINKLERED
THE EXISTING BUILDING IS 100% SPRINKLERED AND ALL MODIFICATIONS FOR NEW DESIGNS WILL CONFORM.
FIRE PROTECTION SYSTEMS -
SPRINKLER SYSTEM
SECTION 903
THE GENERAL CONTRACTOR SHALL COORDINATE WITH THE CITY OF VAIL AND FIRE DEPARTMENTS FOR ALL FIRE ALARM SYSTEM
REQUIREMENTS PRIOR TO THE WORK.
FIRE PROTECTIVE
SIGNALING & DETECTION
SYSTEMS - FIRE ALARM
CHAPTER 9
MIN. EGRESS SEPARATION
1015.2.1
GROUP MERCANTILE - NO CHANGE IN USE GROUP
NUMBER OF EMPLOYEES
MAXIMUM OF 5 EMPLOYEES IN STORE
NO RATING BETWEEN SALES AND STOCKROOM
PARTITION
(1) EXISTING IN SALES AREA;
THE EXISTING BUILDING IS SPRINKLERED
THE CONTRACT DOCUMENTS SHALL CONTAIN SUFFICIENT INFORMATION TO DESCRIBE THE ARCHITECTURAL,
FIRE PROTECTION, FIRE ALARM, ELECTRICAL, MECHANICAL, AND ENERGY CONSERVATION SYSTEMS. THIS
INCLUDES ANY REQUIRED CALCULATIONS, NARRATIVES, AND REPORTS DEEMED NECESSARY BY THE
AUTHORITIES HAVING JURISDICTION.
ENGINEERING DETAILS, REPORTS,
CALCULATIONS, PLANS, & SPECIFICATIONS
MAX. EGRESS PATH
TABLE 1016.1
SHALL NOT EXCEED 250' WITH SPRINKLERS
SIGN AT EXIT DOOR
CHAPTER 10
EGRESS THROUGH THE
STOCK ROOM
SECTION 1014.2
EGRESS SHALL NOT PASS THROUGH KITCHENS, STORAGE ROOMS, CLOSETS OR SPACES USED FOR SIMILAR PURPOSES.
EXCEPTION: MEANS OF EGRESS IS ALLOWED THROUGH STOCKROOMS WHERE ALL THE FOLLOWING ARE MET: STOCK IS SAME HAZARD
CLASSIFICATION AS MAIN RETAIL AREA, NOT MORE THAN 50% EXIT ACCESS IS THROUGH STOCKROOM, STOCKROOM CANNOT BE LOCKED FROM
EGRESS SIDE, AND THERE IS A DEMARCATED MINIMUM 44" WIDE AISLE DEFINED BY FULL OR PARTIAL HEIGHT FIXED WALLS OR SIMILAR
CONSTRUCTION THAT WILL MAINTAIN REQUIRED WIDTH AND LEAD DIRECTLY FROM THE RETAIL AREA TO THE EXIT WITHOUT OBSTRUCTIONS."
HANDICAP ACCESSIBILITY
MINIMUM PLUMBING FIXTURES
EGRESS PATH APPROX. 74'-0"
(FROM MIDPOINT OF PATH OF EGRESS TO EXIT)
THE EXIT SIGNS MUST CONFORM WITH SECTION 1011.0
OVERALL DIAGONAL =
N/A
OVERALL 1/3 DIAGONAL =
N/A
DOOR TO DOOR DISTANCE =
N/A
THIS BUILDING AND SPACE SHALL CONFORM TO THE REQUIREMENTS AND REGULATIONS OF INTERNATIONAL BUILDING CODE
FITTING ROOM REQUIREMENTS:
SEAT/BENCH SHALL BE 24" BY 48" AND FIXED TO THE WALL ALONG THE SHORTER DIMENSION. CODE: CLEAR FLOOR SPACE SHALL BE
PROVIDED ALONGSIDE THE BENCH TO ALLOW A PERSON USING A WHEELCHAIR TO MAKE A PARALLEL TRANSFER ONTO THE SEAT
2012 IMC
2012 IBC
2012 IPC
2012 IECC
2012 IFC
2012 IBC
CITY OF VAIL
75 S FRONTAGE ROAD,
VAIL, CO, 81657
PHONE: 970 479 2128
MECHANICAL
ACCESSIBILITY
PLUMBING
ELECTRICAL
FIRE/LIFE SAFETY CODE
BUILDING DEPARTMENT
TABLE 2902.1 MIN. FACILITIES FOR BLDG. OCCUP.
NOTES:
1. DISTANCE FROM STOREFRONT TO CORE TOILET
FACILITY IS 82'-0".
2. EGRESS PLAN FOR CODE PURPOSES ONLY. REFER TO
A110 FOR CONSTRUCTION PLANS & NOTES.
3. FIRE EXTINGUISHER MOUNTED AT 3’-6” ABOVE FLOOR
MAX.TRAVEL DISTANCE BETWEEN FIRE EXTINGUISHER
– 75 FT.
2 WATER CLOSETS, 1 MALE/ 1 FEMALE
2 LAVATORIES, 1 MALE/ 1 FEMALE
1 DRINKING FOUNTAIN
1 SERVICE SIINK
2 TOILETS (EXISTING)
2 LAVATORY PROVIDED
1 DRINKING FOUNTAIN -
IN LIEU OF DRINKING FOUNTAIN A
SIGNATURE SINK /WATER FEATURE IS
TO BE PROVIDED ACCESSIBLE TO THE
PUBLIC - SEE A822
1 SERVICE (EXISTING)
ENCLOSED VERTICAL EXITS & PASSAGEWAYS - CLASS B
CORRIDORS PROVIDING EXIT ACCESS - CLASS C
ROOMS OR ENCLOSED SPACES - CLASS C
WHERE TWO EXIT DOORS ARE REQUIRED THE EXITS SHALL BE PLACED A DISTANCE APART
EQUAL TO NOT LESS THAN ONE-HALF OF THE LENGTH OF THE MAXIMUM OVERALL DIAGONAL
DIMENSION OF THE BUILDING AREA TO BE SERVED.
EXCEPTION: IN BUILDINGS EQUIPPED THROUGHOUT WITH AN AUTOMATIC SPRINKLER SYSTEM,
THE SEPARATION DISTANCE OF THE EXIT DOORS SHALL NOT BE LESS THAN 1/3 OF THE THE
LENGTH OF THE MAXIMUM OVERALL DIAGONAL.
EGRESS SUMMARY
LEGEND
NUMBER OF EXITS: 1
EGRESS SEPARATIONS: NA
ALLOWED PATH OF TRAVEL (SPRINKLERED)
TO ALL EGRESS (SPRINKLERED):
72'-4 1/2"
74
FE
EXIT SIGN - SALES ONLY
EX1
FIRE EXTINGUISHER
EX3
EMERGENCY LIGHT
F4EM EMERGENCY LIGHT - BOH
EXIT SIGN - NON SALES
EX2
F8EM EMERGENCY LIGHT - BOH
BUILDING
A
B C D
2
1
OVER ALL DIAGONAL 72'-4 1/2"
PATH OF EGRESS
PATH OF EGRESS
PATH OF EGRESS
P
ATH OF E
G
R
E
S
S
3'-8"
3'-8"
3'-8"
3'-8"
3'-8"
WATER FEATURE ELEMENT
ACCESSIBLE, DESIGNED
TO
COMPLY W/ DRINKING
FOUNTAIN REQUIREMENTS
EX1
EX2
REZA A. HADAEGH
402807
S
T
A
T
E
O
F
C
O
L
O
R
A
D
O
L
I
C
E
N
S
E
D
A
R
C
H
I
T
E
C
T
Scale:
Job Number:
Drawing:
LULULEMON ATHLETICA
CONSTRUCTION STANDARDS
Checked By:
Drawn By:
Date:
ISSUED FOR DD-LLL xx/xx/xx
ISSUED FOR DD-LLD
ISSUED FOR CD-LLL 07/31/14
ISSUED FOR CD-LLD 08/14/14
ISSUED FOR PERMIT 08/15/14
ISSUED FOR BID xx/xx/xx
ISSUED FOR SD NA
07/03/14
19780
08/15/14
G003
BLDG. CODE SUMMARY & EGRESS PLAN
NA
BAB
193 EAST GORE CREEK PLAZA
Vail, CO 81657 SCALE: 3/16" = 1'-0" 1
EGRESS PLAN
TRUE
NORTH
NO. DATE
DESCRIPTION
10/08/14