Loading...
HomeMy WebLinkAboutLot 5 Electrical Load calculation.pdfWIRE NUT ELECTRIC INC PO BOX 1112 AVON, CO. 81620 970-926-8855 Load Calculation August 16, 2014 Brian Redinger Solaris Redevelopment Corp. Load Calculation for lot 5 Elk Meadows 300 Amp single phase service for a 3,697 sq. ft. Single Family. General Load: 3,697 X 3VA Lighting 11,091VA 1500 X 6 small appliance circuits 9,000VA 2 Laundry 3,000VA Range 7,560VA Dishwasher 1,200VA Refrigerator 1,200VA 2 Dryers 9,000VA AC load greater than heating load including Heat Tape 14,500VA Spa Tub 12,000VA Steam Unit 12,000VA Total 80,551VA First 10 KVA @ 100% 10,000VA Remainder of General Load @ 40% 70,551 X 40% 28,220VA Total General Load 38,220VA 38,220VA / 240V = 159 Amps We are going with a 300 amp service to allow for expansion of future electrical needs. Thank You Please call with any questions