Lot 5 HLHG Summary.pdf
HEAT LOSS / HEAT GAIN SUMMARY JOB NAME:Elk Meadows JOB NUMBER:14037 DATE:8/20/2014 CALCS BY:DRC (USER SHALL INPUT YELLOW CELLS) SITE ELEVATION =8150 Wall Insulation (avg)R-23.5 TRANSFER FACTOR = 0.79 Roof Insulation (avg)R-58.6 COOLING AIRFLOW DT =20 Infiltration (nach)0.3 WINDOW VALUES (U, S.C.)0.32, 0.46 Winter Design Temp (indoor/ outdoor)70 / -20 LIGHTING LOAD (W/S.F.)1, 3 Summer Design Temp (indoor/ outdoor)75 / 90 ROOM FLOOR AREA EFFECTIVE (SF)AREA (SF)SENS LATENT TOTAL BTU/H BTU/SF 101-Garage 631 631 5500 0 5500 11800 19 103-Mud 109 79 400 0 400 400 5 104-Entry, Hall, & Storage 290 240 6400 0 6400 11300 47 108-Guest Bath & Closet 97 69 1000 0 1000 300 4 110-Guest Bed 200 200 3200 130 3330 4300 22 111-Family 302 302 4200 300 4500 6700 22 112-Bath 1 66 33 600 0 600 1100 33 113-Bed 1 205 205 2500 90 2590 3800 19 202-Laundry & Pantry 100 53 1700 0 1700 1500 28 203-Powder 29 20 400 0 400 200 10 204-Bath 2 56 28 700 0 700 1000 36 205-Bed 2 219 186 2400 190 2590 3900 21 207-Study 143 95 3400 150 3550 4200 44 209-Kitchen & Hall 297 196 9600 0 9600 5000 26 210-Dining & Living 678 664 16800 720 17520 15800 24 212-Master Hall 69 69 1100 0 1100 1600 23 213-Master Closet 60 34 300 0 300 300 9 214-Master Bath 150 99 2800 0 2800 2500 25 215-Master Bed 206 188 6000 390 6390 6400 34 TOTALS / AVG'S.3907 69000 1970 70970 82100 21 LOT 5 COOLING HEATING 8/20/14