HomeMy WebLinkAboutB14-0308 REV1 panel schedule.pdfPROJECT: ANTLERS 701 & 702ENGINEER: SOHPROJECT #: 14065VOLTAGE: 120/208V, 1P, 3WMOUNTING: RECESSEDMAINS: 150A MLOTYPE: QO RESIDENTIALAIC: 10KPHASE PHASEDESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTIONELECTRIC BASEBOARD 1188 20 2 1 2 1 15 100 SMOKES" 1188 3 4 1 20 1000 UNIDENTIFIEDELECTRIC BASEBOARD 1188 20 2 5 6 1 20 1000 STAIR DINING" 1188 7 8 1 20 180 2ND FLOOR BATHELECTRIC BASEBOARD 1188 20 2 9 10 1 20 1500 KITCHEN CIRCUIT" 1188 11 12 1 20 1500 KITCHEN CIRCUITUNIDENTIFIED 1000 20 1 13 14 1 20 1000 DISPOSALUNIDENTIFIED 1000 20 1 15 16 1 20 1000 KITCHEN CIRCUITRANGE 4000 50 2 17 18 1 20 1000 DISHWASHER" 4000 19 20 1 20 180 DORM BATHOUTSIDE LIGHTS 100 20 1 21 22 1 20 900 DORM STAIRS2ND FLOOR RECEPTACLES 900 20 1 23 24 2 30 2250 WATER HEATERSMOKES 100 20 1 25 26 2250 "ELECTRIC BASEBOARD 1188 30 2 27 28 2 30 2500 STACKED WASHER DRYER" 1188 29 30 2500 "LIVING ROOM REC 900 20 1 31 32 0 SPACESPACE 0 33 34 0 SPACESPACE 0 35 36 0 SPACESPACE 0 37 38 0 SPACESPACE 0 39 40 0 SPACESPACE 0 41 42 0 SPACELOAD CALCULATION SUMMARY NOTE: PROVIDE ARC-FAULT CIRCUIT INTERRUPTER, COMBINATION-TYPE CIRCUIT BREAKERS FOR BRANCH CIRCUITS SUPPLYING ALL 120V POWER OUTLETS AS REQUIRED BY CODECALCULATED POWER FACTOR: REPLACE EXISTING PANEL WITH NEW AS SCHEDULED HERE. SET NEW0.94 CIRCUIT FOR W/D. TIGHTEN LUGS AT METERBANK.CONNECTED LOADCONNECTED AMPSDEMAND LOAD DEMAND AMPSAPPLIANCES 0 0 0 0LIGHTING & RECEPT. 13360 64 6626 32MECHANICAL 14000 67 15125 73KITCHEN OVEN & DRYER 13000 63 13000 63TOTAL 40360 194 34751 SEE DEMAND LOAD CALCULATIONS PANEL 7029/26/2014