Loading...
HomeMy WebLinkAboutA0.03.pdf24' - 5" 20' - 5 3/4" 37' - 5 1/4" 24' - 2" 20' - 2 3/4" 15' - 6" 16' - 0" PROJECT NUMBER ISSUE DATE 710 W. COLFAX; DENVER, C0 80204 REVISION SHEET TITLE ISSUE SHEET NO. KEY PLAN VAIL 21 VAIL, COLORADO A0.03 AREA EXHIBIT 14040.000 TENANT IMPROVEMENTS SUITE 301 & 302 CONSTRUCTION DOCUMENTS SEPTEMBER 08 2014 No. Description Date 1 REV. 1 - PERMIT RESPONSES 09.18.14 1/4" = 1'-0" 01SUITE 301 AND 302 GRFA PLAN 1 Re-Note 11: The drawings submitted showed unit usable square footage in our original submittal The revised drawings shown here illustrate the GRFA in compliance with the TOV. The floor area is defined as the total square footage of all levels of a building, as measured at the inside face of the exterior walls 1 TOWN OF VAIL CODE 12-15-3 - GRFA ͷ. Gross Residential Floor Area Defined: For residential uses, the total square footage of all horizontal areas on all levels of a structure, as mea- sured to the outside face of the sheathing of the exterior walls (i.e., not in- cluding exterior wall finishes). Floor area shall include, but not be limited to, elevator shafts and stairwells at each level, lofts, fireplaces, bay windows, mechanical spaces, vents and chases, storage areas, and other similar areas. Garages; attics; vaulted or open to below spaces; basements; crawl spaces; and roofed or covered decks, porches, terraces, or patios shall be included as floor area; except the horizontal areas of a structure as set forth herein shall then be deducted from the calculation of GRFA. Units (inc exterior face of the wall) contributing to GRFA ͹Ͷͷ = ;ͽͷ sq ft GRFA ͹Ͷ͸ = ;ͻ; sq ft GRFA Total = ͷͽ͸Ϳ sq ft GRFA System No. W-J-7022 SECTION A-A WJ 7022 :DOO$VVHPEO\²0LQLQDQGLQߛDQGPPߜWKLFNUHLQIRUFHGOLJKWZHLJKWRUQRUPDOZHLJKWߛSFIRUNJPߜ concrete for 1 and 2 hr ratings , respectively. Wall may also be constructed of any UL Classified Concrete Blocks*. Max diam of opening is 21- 1/2 in (546 mm). See Concrete Blocks (CAZT) category in the Fire Resistance Directory for names of manufacturers. 7KURXJK3HQHWUDQW²1RPJDOYVWHHOGXFWWREHLQVWDOOHGFRQFHQWULFDOO\RUHFFHQWULFDOO\ZLWKLQWKHILUHVWRSV\VWHP7KHDQQXODUVSDFHEHWZHHQ duct and periphery of opening shall be min 0 in. (point contact) and max 1-1/2 in. (38 mm). Duct to be rigidly supported on both sides of wall assembly. $6SLUDO:RXQG+9$&'XFW²1RPLQߛPPߜGLDPߛRUVPDOOHUߜ1R06*ߛRUKHDYLHUߜJDOYVWHHOVSLUDOZRXQGGXFW $6KHHW0HWDO'XFW²1RPLQߛPPߜGLDPߛRUVPDOOHUߜ1R06*ߛRUKHDYLHUߜJDOYVKHHWVWHHOGXFW )LOO9RLGRU&DYLW\0DWHULDOߝ²6HDODQW²0LQLQDQGLQߛDQGPPߜWKLFNQHVVRIILOOPDWHULDODSSOLHGZLWKLQDQQXOXVIOXVKZLWKERWK surfaces of wall assembly for 1 or 2 hr F Ratings, respectively. At the point contact location between duct and periphery of opening, a min 1/2 in. (13 mm) diam bead of sealant shall be applied at the periphery/duct interface on both surfaces of wall assembly. +,/7,&216758&7,21&+(0,&$/6',92)+,/7,,1&²&36(ODVWRPHULF)LUHVWRS6HDODQW&)666,/**6HDODQW)621(6HDODQWRU CP606 Flexible Firestop Sealant *Bearing the UL Classification Mark A Reproduced by HILTI, Inc. Courtesy of Underwriters Laboratories, Inc. January 14, 2014 A 3 2 3 1 C C L A S S I F I E D Classified by Underwriters Laboratories, Inc. to UL 1479 and CAN/ULC-S115 US ANSI/UL1479 (ASTM E814) CAN/ULC S115 )5DWLQJV²ߙ+Uߛ6HH,WHPVDQGߜ )5DWLQJV²ߙ+Uߛ6HH,WHPVDQGߜ 75DWLQJ²+U )75DWLQJ²+U )+5DWLQJV²ߙ+Uߛ6HH,WHPVDQGߜ )7+5DWLQJ²+U Fire rating assembly for penetrations 10/07/14