HomeMy WebLinkAboutA0.2.pdf? ? 5 5 106'-6" TRAVEL DISTANCE IN COMPLIANCE WITH IBC 2012 SECTION 1016; TABLE 1016.2 EXISTING ELEVATOR ONE HOUR TWO HOUR 1 DIRECTION OF TRAVEL NO. OF OCCUPANTS ANTICIPATED OCCUPANT LOAD EGRESS LEGEND LINE OF TRAVEL DISTANCE BUILDING SUMMARY 1. PROJECT INFORMATION PROJECT NAME: Tenant Improvements Suites 301 & 302 ADDRESS: 521 E Lionshead Circle, PROPOSED USE: Residential OWNER-CONTACT PERSON: Linda Malaby: linda.malaby@gmail.com PHONE: 970-376-1553 2. APPLICABLE CODES - BUILDING CODE: IBC 2012 - MECHANICAL: IMC 2012 - PLUMBING: UPC 2012 - ELECTRICAL: NEC 2011 - FIRE CODE: IFC 2012 - STATE/CITY AMENDMENTS: City of Vail Ordinances - ENERGY CODE: IECC 2012 3. USE AND OCCUPANCY CLASSIFICATION A. OCCUPANCY: R2 - Residential B. MIXED OCCUPANCY? YES / NO C. REQUIRED FIRE SEPARATION: N/A 5. TYPE OF CONSTRUCTION CONSTRUCTION TYPE: III-B 4. GENERAL BUILDING LIMITATIONS ITEM REQ'D RATING / HR A. STRUCTURAL FRAME B. BEARING WALLS - EXTERIOR C. BEARING WALLS - INTERIOR D. NON-BEARING WALLS - EXTERIOR E. NON-BEARING WALLS - INTERIOR F. FLOOR CONSTRUCTION G. ROOF CONSTRUCTION 0 HR 2 HR 0 HR 0 HR 0 HR 0 HR 0 HR ESSENTIAL FACILITY? YES / NO HIGH RISE? YES / NO * Building height and area is not being modified in this proposal. Refer to building permit no. B14-0040 for detailed information regarding building limitations 1. BUILDING ELEMENTS: * TYPE OF CONSTRUCTION AND FIRE RESISTIVE REQUIREMENTS are not being modified in this proposal. Refer to building permit no. B14-0040 for detailed information regarding construction type. ** UNIT DEMISING WALLS must maintain 1 HR fire separation. Seal any penetrations with UL approved fire caulking and meet the requirements of IBC section 708 ***The location of the unit demising wall is clouded in this revision set. The wall is existing and built to the standard of UL design #U905. There are no new penetrations planned at this time. Since there is no planned penetrations through this wall, the disclaimer of providing fire caulk will be removed. 6. FIRE PROTECTION SYSTEMS * The FIRE PROTECTION SYSTEMS shall comply with the agreements made for the whole building remodel as outlined in permit number: B14-0040. that states: 1. Each unit shall have the agreed upon fire/smoke/heat/ and carbon monoxide detection sensors as detailed in Phase 2 of the agreement letter. 2. Smoke/Heat detection sensors will be located in each sleeping room as detailed in Phase 3 of the agreement letter. 7. EXIT REQUIREMENTS * The units are existing and will not be modifying the current EXITING REQUIREMENT occupant load AND will meet the requirements of section 1005 FUNCTION OF SPACE OCCUPANT LOAD FACTOR RESIDENTIAL 200 gross = 5 Occupants 8. ACCESSIBILITY * THE BUILDING ACCESSIBILITY COMPLIES WITH THE CODE AT THE TIME OF CONSTRUCTION, BUT ACCORDING TO THE IBC 2012 SECTION 3402 EXISTING BUILDINGS - PROVISION FOR TECHNICALLY INFEASIBLE: BECAUSE OF THE EXISTING CONDITIONS IT IS TECHNICALLY INFEASIBLE TO MEET THE ACCESSIBILITY REQUIREMENTS WITHOUT SUBSTANTIAL MODIFICATION TO THE STRUCTURAL FRAME OF THE BUILDING. THE UNIT RENOVATION ITSELF HAS BEEN DESIGNED TO MEET THE CODE REQUIREMENTS OF AN R2 OCCUPANCY. ALL DOOR, APPLIANCE, AND SERVICE CLEARANCES HAVE BEEN MET. THE TECHNICALLY INFEASABLE ELEMENT TO THIS DESIGN IS IN REGARD TO THE EXISTING ELEVATOR. THOUGH THERE IS AN ELEVATOR TO BRING THE OCCUPANTS TO THE UNIT, THIS EXISTING STRUCTURE DOES NOT MEET THE ACCESSIBILITY REQUIREMENTS OF TODAY’S CODE AS IT WAS DESIGNED AND BUILD IN 1970. THIS STRUCTURE IS OUTSIDE OF THE SCOPE OF THIS REMODEL. 359 DESIGN WANTED TO MAKE NOT OF THIS IMPEDIMENT. ** The Unit plans shall meet all door widths and comply with IBC 2012: Chapter 11 9. PLUMBING FIXTURE REQUIREMENTS PER TABLE 2902.1: CLASSIFICATION RESIDENTIAL OCC. DESCRIPTION WATER CLOSETS LAVATORIES BATH FOUNTAINS OTHERS R2 APARTMENT 1 PER UNIT 1 PER UNIT 1 PER UNIT -N/A- 1 KITCHEN SINK W/D HOOK-UP 1 PROJECT NUMBER ISSUE DATE 710 W. COLFAX; DENVER, C0 80204 REVISION SHEET TITLE ISSUE SHEET NO. 521 EAST LIONSHEAD CIRCLE VAIL, COLORADO 81657 A0.02 CODE ANALYSIS AND EGRESS PLAN 14040.000 TENANT IMPROVEMENTS SUITE 301 & 302 CONSTRUCTION DOCUMENTS SEPTEMBER 08 2014 3/16" = 1'-0" 1EGRESS PLAN 6' OCCUPANCY LOAD FACTOR Unit Number Unit SF Occupancy Type Occupancy Load Factor Occupancy Load 301 871 SF Residential 200 5 302 858 SF Residential 200 5 No. Description Date 1 REV. 1 - PERMIT RESPONSES 09.18.14 1 1 10/07/14