TRAVEL DISTANCE IN COMPLIANCE WITH
IBC 2012 SECTION 1016; TABLE 1016.2
EXISTING ELEVATOR
ONE HOUR
TWO HOUR
1
DIRECTION OF
TRAVEL
NO. OF OCCUPANTS
ANTICIPATED
OCCUPANT LOAD
EGRESS LEGEND
LINE OF TRAVEL
DISTANCE
BUILDING SUMMARY
1. PROJECT INFORMATION
PROJECT NAME: Tenant Improvements Suites 301 & 302
ADDRESS: 521 E Lionshead Circle,
PROPOSED USE: Residential
OWNER-CONTACT PERSON: Linda Malaby: linda.malaby@gmail.com
PHONE: 970-376-1553
2. APPLICABLE CODES
- BUILDING CODE: IBC 2012
- MECHANICAL: IMC 2012
- PLUMBING: UPC 2012
- ELECTRICAL: NEC 2011
- FIRE CODE: IFC 2012
- STATE/CITY
AMENDMENTS: City of Vail Ordinances
- ENERGY CODE: IECC 2012
3. USE AND OCCUPANCY CLASSIFICATION
A. OCCUPANCY: R2 - Residential
B. MIXED OCCUPANCY? YES / NO
C. REQUIRED FIRE SEPARATION: N/A
5. TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: III-B
4. GENERAL BUILDING LIMITATIONS
ITEM REQ'D RATING / HR
A. STRUCTURAL FRAME
B. BEARING WALLS - EXTERIOR
C. BEARING WALLS - INTERIOR
D. NON-BEARING WALLS - EXTERIOR
E. NON-BEARING WALLS - INTERIOR
F. FLOOR CONSTRUCTION
G. ROOF CONSTRUCTION
0 HR
2 HR
0 HR
0 HR
0 HR
0 HR
0 HR
ESSENTIAL FACILITY? YES / NO
HIGH RISE? YES / NO
* Building height and area is not being modified in this proposal. Refer to building
permit no. B14-0040 for detailed information regarding building limitations
1. BUILDING ELEMENTS:
* TYPE OF CONSTRUCTION AND FIRE RESISTIVE REQUIREMENTS are not
being modified in this proposal. Refer to building permit no. B14-0040 for detailed
information regarding construction type.
** UNIT DEMISING WALLS must maintain 1 HR fire separation. Seal any
penetrations with UL approved fire caulking and meet the requirements of IBC
section 708
***The location of the unit demising wall is clouded in this revision set.
The wall is existing and built to the standard of UL design #U905.
There are no new penetrations planned at this time. Since there is no planned
penetrations through this wall, the disclaimer of providing fire caulk will be
removed.
6. FIRE PROTECTION SYSTEMS
* The FIRE PROTECTION SYSTEMS shall comply with the agreements made for the whole building
remodel as outlined in permit number: B14-0040. that states:
1. Each unit shall have the agreed upon fire/smoke/heat/ and carbon monoxide detection sensors
as detailed in Phase 2 of the agreement letter.
2. Smoke/Heat detection sensors will be located in each sleeping room as detailed in Phase 3 of
the agreement letter.
7. EXIT REQUIREMENTS
* The units are existing and will not be modifying the current EXITING REQUIREMENT occupant load AND
will meet the requirements of section 1005
FUNCTION OF SPACE OCCUPANT LOAD FACTOR
RESIDENTIAL 200 gross = 5 Occupants
8. ACCESSIBILITY
* THE BUILDING ACCESSIBILITY COMPLIES WITH THE CODE AT THE TIME OF CONSTRUCTION,
BUT ACCORDING TO THE IBC 2012 SECTION 3402 EXISTING BUILDINGS - PROVISION FOR
TECHNICALLY INFEASIBLE: BECAUSE OF THE EXISTING CONDITIONS IT IS TECHNICALLY
INFEASIBLE TO MEET THE ACCESSIBILITY REQUIREMENTS WITHOUT SUBSTANTIAL
MODIFICATION TO THE STRUCTURAL FRAME OF THE BUILDING.
THE UNIT RENOVATION ITSELF HAS BEEN DESIGNED TO MEET THE CODE REQUIREMENTS OF
AN R2 OCCUPANCY. ALL DOOR, APPLIANCE, AND SERVICE CLEARANCES HAVE BEEN MET. THE
TECHNICALLY INFEASABLE ELEMENT TO THIS DESIGN IS IN REGARD TO THE EXISTING
ELEVATOR. THOUGH THERE IS AN ELEVATOR TO BRING THE OCCUPANTS TO THE UNIT, THIS
EXISTING STRUCTURE DOES NOT MEET THE ACCESSIBILITY REQUIREMENTS OF TODAY’S
CODE AS IT WAS DESIGNED AND BUILD IN 1970. THIS STRUCTURE IS OUTSIDE OF THE SCOPE
OF THIS REMODEL. 359 DESIGN WANTED TO MAKE NOT OF THIS IMPEDIMENT.
** The Unit plans shall meet all door widths and comply with IBC 2012: Chapter 11
9. PLUMBING FIXTURE REQUIREMENTS
PER TABLE 2902.1:
CLASSIFICATION
RESIDENTIAL
OCC. DESCRIPTION WATER CLOSETS LAVATORIES BATH FOUNTAINS OTHERS
R2 APARTMENT 1 PER UNIT 1 PER UNIT 1 PER UNIT -N/A- 1 KITCHEN SINK
W/D HOOK-UP
1
PROJECT NUMBER
ISSUE DATE
710 W. COLFAX; DENVER, C0 80204
REVISION
SHEET TITLE
ISSUE
SHEET NO.
521 EAST LIONSHEAD CIRCLE
VAIL, COLORADO 81657
A0.02
CODE ANALYSIS AND
EGRESS PLAN
14040.000
TENANT IMPROVEMENTS
SUITE 301 & 302
CONSTRUCTION
DOCUMENTS
SEPTEMBER 08 2014
3/16" = 1'-0"
1EGRESS PLAN
6'
OCCUPANCY LOAD FACTOR
Unit
Number Unit SF
Occupancy
Type
Occupancy
Load Factor
Occupancy
Load
301 871 SF Residential 200 5
302 858 SF Residential 200 5
No. Description Date
1 REV. 1 - PERMIT RESPONSES 09.18.14
1
1
10/07/14