HomeMy WebLinkAboutE1.1.pdfSCALE:1UNIT 301 ELECTRICAL PLAN 1/4" = 1'-0" WP REF DW C C C C CC C S TV +72" SPANEL:EXISTING UNIT PANEL VOLTAGE: 120/240V, 1PH, 3W MINIMUM BUS:125 LOCATION: BEDROOM 2 MAIN: MLO MOUNTING: RECESSED MINIMUM AIC:10,000 NO.LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO.A B POLE TRIP A B TRIP POLE A B 1 R BEDROOM 1 RECEP. (1)1 20 +20 1 L BEDRMS AND BATH LTG (1)2 3 R BATHROOM 1 RECEP. 1 20 +20 1 L KITCH LIV/DINING LTG (1)4 5 R BATHROOM 2 RECEP. 1 20 +20 1 FIRE ALARM 6 7 R BEDROOM 2 RECEP. (1)1 20 +50 2 A RANGE/OVEN 8 9 R LIVING ROOM RECEP.(1) 1 20 +A 10 11 R DINING RECEP.(1) 1 20 +20 1 A MICROWAVE/HOOD 12 13 R KITCHEN RECEP. 1 20 +20 1 A REFRIGERATOR 14 15 A DISHWASHER 1 20 +20 1 E SPARE 16 17 A DISPOSAL 1 20 +18 19 +20 21 +22 23 +24 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125%0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LRG. MOTOR 0 0 25%0 D. (M) MOTORS (ALL)0 0 100%0 E. (E) EQUIPMENT 0 0 100%0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1)PROVIDE AFCI TYPE CIRCUIT BREAKERS PANEL TOTAL (KVA):0.0 (2) (3) PANEL TOTAL (A):0 (4) (5) +72" EF 1 EF 1 SPOWER FOR 120V TO 24 VOLT THERMOSTAT TRANSFORMER. EXISTING GENERAL ELECTRIC 125A, 120/240V, 1ɸ, 24 SPACE UNIT PANEL. FEED AND WIRE SIZED 100A 2-POLE. 1 FLAG NOTES: 1 J J 1 J 2 1.ALL RECEPTACLES IN GREAT ROOM, TV ROOM, BEDROOMS, KITCHEN, AND OTHER SIMILAR ROOMS SHALL BE TAMPER RESISTANT IN ACCORDANCE WITH NEC 406.12. 2.20 AMP, 120 VOLT BRANCH CIRCUITS SHALL BE AFCI RATED IN COMPLIANCE WITH NEC 210.12, EXCEPT FOR KITCHEN AND BATHROOMS. NOTES: 2 1 S N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD)BY: LTA DATE: 7/31/2014 PROJECT NAME:VAIL 21 RENOVATION BUILDING: UNIT #:VOLTAGE: PHASE: -301/2 240 1 . LIGHTING & GENERAL RECEPTACLES AREA(S.F.): VA / S.F.LOAD 814 3 =2442 VA SMALL APPLIANCES 2 1500 =3000 VA LAUNDRY CIRCUITS: 0 1500 =0 VA 5442 VA First 3000VA 100%=3000 VA From 3001 to 120,000VA 35%=855 VA Over 120,000VA 25%=0 VA 3854.7 VA x100% =3855 VA APPLIANCES: APPLIANCE #LOAD TOTAL VENT HOOD 1 300 VA =300 VA DISHWASHER 1 1200 VA =1200 VA GARBAGE DISPOSAL 1 1200 VA =1200 VA REFRIGERATOR 1 1200 VA =1200 VA 3900 VA x 75% =2925 VA NEC 220.17 APPLIANCES: RANGE 1 8000 VA =8000 VA 8000 VA x 100% =8000 VA MECHANICAL EQUIPMENT: EXHAUST FAN 2 12 VA =24 VA TOTAL UNIT MECH LOAD: 24 X 100% =24 VA TOTAL PRE-DEMAND ELECTRICAL LOAD:17366 VA TOTAL DEMAND ELECTRICAL LOAD:14804 VA MINIMUM ELECTRICAL SERVICE SIZE:61.7AMPS RANGE/OVEN MW/HOOD S DISP 1 SCALE: 1 UNIT 301 ELECTRICAL PLAN 1/4" = 1'-0" WP REF DW C C C C C C C S TV +72" S PANEL: EXISTING UNIT PANEL VOLTAGE: 120/240V, 1PH, 3W MINIMUM BUS: 125 LOCATION: BEDROOM 2 MAIN: MLO MOUNTING: RECESSED MINIMUM AIC: 10,000 NO. LOAD TYPE LOAD DESCRIPTION BREAKER BUS BREAKER TYPE LOAD DESCRIPTION LOAD NO. A B POLE TRIP A B TRIP POLE A B 1 R BEDROOM 1 RECEP. (1) 1 20 + 20 1 L BEDRMS AND BATH LTG (1) 2 3 R BATHROOM 1 RECEP. 1 20 + 20 1 L KITCH LIV/DINING LTG (1) 4 5 R BATHROOM 2 RECEP. 1 20 + 20 1 FIRE ALARM 6 7 R BEDROOM 2 RECEP. (1) 1 20 + 50 2 A RANGE/OVEN 8 9 R LIVING ROOM RECEP.(1) 1 20 + A 10 11 R DINING RECEP.(1) 1 20 + 20 1 A MICROWAVE/HOOD 12 13 R KITCHEN RECEP. 1 20 + 20 1 A REFRIGERATOR 14 15 A DISHWASHER 1 20 + 20 1 E SPARE 16 17 A DISPOSAL 1 20 + 18 19 + 20 21 + 22 23 + 24 LOAD TYPE PANEL TOTAL FEED THRU TOTAL SUBFEED TOTAL FEEDER SUBTOTAL DEMAND FEEDER TOTAL GENERAL NOTES: A. (L) LIGHTING 0 0 125% 0 B. (R) RECEPTACLES 0 0 NEC 220 0 C. (LM) LRG. MOTOR 0 0 25% 0 D. (M) MOTORS (ALL) 0 0 100% 0 E. (E) EQUIPMENT 0 0 100% 0 SPECIFIC NOTES: (A) APPLIANCES 0 0 0 0 (1) PROVIDE AFCI TYPE CIRCUIT BREAKERS PANEL TOTAL (KVA): 0.0 (2) (3) PANEL TOTAL (A): 0 (4) (5) +72" EF 1 EF 1 S POWER FOR 120V TO 24 VOLT THERMOSTAT TRANSFORMER. EXISTING GENERAL ELECTRIC 125A, 120/240V, 1 ɸ, 24 SPACE UNIT PANEL. FEED AND WIRE SIZED 100A 2-POLE. 1 FLAG NOTES: 1 J J 1 J 2 1. ALL RECEPTACLES IN GREAT ROOM, TV ROOM, BEDROOMS, KITCHEN, AND OTHER SIMILAR ROOMS SHALL BE TAMPER RESISTANT IN ACCORDANCE WITH NEC 406.12. 2. 20 AMP, 120 VOLT BRANCH CIRCUITS SHALL BE AFCI RATED IN COMPLIANCE WITH NEC 210.12, EXCEPT FOR KITCHEN AND BATHROOMS. NOTES: 2 1 S N.E.C. LOAD CALCULATION FOR DWELLING UNITS (STANDARD) BY: LTA DATE: 7/31/2014 PROJECT NAME: VAIL 21 RENOVATION BUILDING: UNIT #: VOLTAGE: PHASE: -301/2 240 1 . LIGHTING & GENERAL RECEPTACLES AREA(S.F.): VA / S.F. LOAD 814 3 = 2442 VA SMALL APPLIANCES 2 1500 = 3000 VA LAUNDRY CIRCUITS: 0 1500 = 0 VA 5442 VA First 3000VA 100% = 3000 VA From 3001 to 120,000VA 35% = 855 VA Over 120,000VA 25% = 0 VA 3854.7 VA x 100% =3855 VA APPLIANCES: APPLIANCE # LOAD TOTAL VENT HOOD 1 300 VA = 300 VA DISHWASHER 1 1200 VA = 1200 VA GARBAGE DISPOSAL 1 1200 VA = 1200 VA REFRIGERATOR 1 1200 VA = 1200 VA 3900 VA x 75% = 2925 VA NEC 220.17 APPLIANCES: RANGE 1 8000 VA = 8000 VA 8000 VA x 100% = 8000 VA MECHANICAL EQUIPMENT: EXHAUST FAN 2 1 2 VA =24 VA TOTAL UNIT MECH LOAD: 24 X 100% = 24 VA TOTAL PRE-DEMAND ELECTRICAL LOAD: 17366 VA TOTAL DEMAND ELECTRICAL LOAD: 14804 VA MINIMUM ELECTRICAL SERVICE SIZE: 61 .7 AMPS RANGE/OVEN MW/HOOD S DISP 1 E1.1 MAS MAS SUITE 301 ELECTRICAL PLAN VAIL, COLORADO 2465.06 07-31-14 SHEET TITLE: NO. Job no.: REVISION Drawn by: Date: Designed by: DATE BY BUILDING IMPROVMENTS VAIL 21 EAUDIN ANZE COPYRIGHT 2014 B G C:\Users\cadd-txc\local settings\temp\AcPublish_9040\246506E11.dwg Printed By: cadd-txc September 18, 2014 - 4:29pm LC-XXX Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 REVISION 1 MAS 9-18-14 10/07/14