HomeMy WebLinkAboutVail 21 - Unit 402 - A0.02.pdfBUILDING SUMMARY
1. PROJECT INFORMATION
PROJECT NAME: Tenant Improvements Suites 301 & 302
ADDRESS: 521 E Lionshead Circle,
PROPOSED USE: Residential
OWNER-CONTACT PERSON: Linda Malaby: linda.malaby@gmail.com
PHONE: 970-376-1553
2. APPLICABLE CODES
- BUILDING CODE: IBC 2012
- MECHANICAL: IMC 2012
- PLUMBING: UPC 2012
- ELECTRICAL: NEC 2011
- FIRE CODE: IFC 2012
- STATE/CITY
AMENDMENTS: City of Vail Ordinances
- ENERGY CODE: IECC 2012
3. USE AND OCCUPANCY CLASSIFICATION
A. OCCUPANCY: R2 - Residential
B. MIXED OCCUPANCY? YES / NO
C. REQUIRED FIRE SEPARATION: N/A
5. TYPE OF CONSTRUCTION
CONSTRUCTION TYPE: III-B
4. GENERAL BUILDING LIMITATIONS
ITEM REQ'D RATING / HR
A. STRUCTURAL FRAME
B. BEARING WALLS - EXTERIOR
C. BEARING WALLS - INTERIOR
D. NON-BEARING WALLS - EXTERIOR
E. NON-BEARING WALLS - INTERIOR
F. FLOOR CONSTRUCTION
G. ROOF CONSTRUCTION
0 HR
2 HR
0 HR
0 HR
0 HR
0 HR
0 HR
ESSENTIAL FACILITY? YES / NO
HIGH RISE? YES / NO
* Building height and area is not being modified in this proposal. Refer to building
permit no. B14-0040 for detailed information regarding building limitations
1. BUILDING ELEMENTS:
* TYPE OF CONSTRUCTION AND FIRE RESISTIVE REQUIREMENTS are not being
modified in this proposal. Refer to building permit no. B14-0040 for detailed information
regarding construction type.
** UNIT DEMISING WALLS must maintain 1 HR fire separation. Seal any penetrations
with UL approved fire caulking and meet the requirements of IBC section 708
6. FIRE PROTECTION SYSTEMS
* The FIRE PROTECTION SYSTEMS shall comply with the agreements made for the whole building
remodel as outlined in permit number: B14-0040. that states:
1. Each unit shall have the agreed upon fire/smoke/heat/ and carbon monoxide detection sensors
as detailed in Phase 2 of the agreement letter.
2. Smoke/Heat detection sensors will be located in each sleeping room as detailed in Phase 3 of
the agreement letter.
7. EXIT REQUIREMENTS
* The units are existing and will not be modifying the current EXITING REQUIREMENT occupant load AND
will meet the requirements of section 1005
FUNCTION OF SPACE OCCUPANT LOAD FACTOR
RESIDENTIAL 200 gross = 5 Occupants
8. ACCESSIBILITY
* THE BUILDING ACCESSIBILITY COMPLIES WITH THE CODE AT THE TIME OF CONSTRUCTION, BUT
ACCORDING TO THE IBC 2012 SECTION 3402 EXISTING BUILDINGS - PROVISION FOR TECHNICALLY
INFEASIBLE: BECAUSE OF THE EXISTING CONDITIONS IT IS TECHNICALLY INFEASIBLE TO MEET THE
ACCESSIBILITY REQUIREMENTS WITHOUT SUBSTANTIAL MODIFICATION TO THE STRUCTURAL FRAME
OF THE BUILDING.
** The Unit plans shall meet all door widths and comply with IBC 2012: Chapter 11
9. PLUMBING FIXTURE REQUIREMENTS
PER TABLE 2902.1:
CLASSIFICATION
RESIDENTIAL
OCC. DESCRIPTION WATER CLOSETS LAVATORIES BATH FOUNTAINS OTHERS
R2 APARTMENT 1 PER UNIT 1 PER UNIT 1 PER UNIT -N/A- 1 KITCHEN SINK
W/D HOOK-UP