HomeMy WebLinkAboutA0-00 - COVER.pdf°
±
W/
<
Room name
101
100'-0"
LEVEL INDICATOR
A101
1
SIM
100'-0"
SPOT ELEVATION
1
A101
SIM
DETAIL NUMBER
SHEET WHERE SHOWN
SECTION LETTER
SHEET WHERE SHOWN
DETAIL DESIGNATOR
BUILDING SECTION DESIGNATOR
1
101 DOOR DESIGNATOR
1i WINDOW DESIGNATOR
0 REFERENCE
CW1(E) WALL TYPE
1
ADDENDUM
REVISED AREA
OF DRAWING
DRAWING CONVENTIONS
GENERAL PROJECT NOTES:
- BLOWER DOOR TEST REQUIRED, TEST BY OTHERS,
COORDINATED BY GC
- RADON SYSTEM TO BE INSTALLED, RE: MEP, FOR ANY RADON
RELATED CONCERNS REFER TO M2 SERIES DRAWINGS FOR
PIPING AND DETAILS
- COMPLETE RES CHECK FOR CODE COMPLIANCE COMPLETED
AND SUBMITTED TO THE TOV, RE: MEP
- PRESCRIPTIVE BUILDING ENVELOPE (R-50 @ ROOF, R-23 @
WALLS, R-10 @ FOUNDATION)
- HIGH EFFICIENCY LIGHTING REQUIREMENTS WILL BE PROVIDE
BY THE LIGHTING SUPPLIER
- ALL ELEVATIONS ARE TAKEN FROM T.O. LIGHT WEIGHT
CONCRETE TOPPING, UNLESS OTHERWISE STATED.
- ALL DIMENSIONS TAKEN FROM STUD FACE.
TOTAL SQUARE FOOTAGE OVERVIEW
UNIT A
2305 SQ FT
1ST FLOOR
2ND FLOOR
BASEMENT
TOTAL SF
UNIT B
2425 SQ FT
1668 SQ FT
1920 SQ FT
TOTAL SF
4730 SQ FT
3588 SQ FT
1532 SQ FT
1596 SQ FT
3128 SQ FT
5505 SQ FT
5941 SQ FT
11446 SQ FT
PARCEL OVERVIEW
SF
PARCEL A
PARCEL B
PARCEL C
23678 SQ FT
11803 SQ FT
11700 SQ FT
175 SQ FT
TOTAL SITE SF
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
A0.00
COVER
MERIBEL CORPORATION
Project Number - 1428
03/18/15
CD SET
MISC. ABBREVIATIONS
ROUND
WITH
DEGREES
PLUS OR MINUS
PROPERTY LINE
ANGLE
CENTER LINE
ADMINISTRATIVE INFO.
BUILDING CODE SUMMARY
PROJECT DIRECTORY
BUILDING CODE: 2012 IRC
CONSTRUCTION TYPE: TYPE V-A
DWELLING UNITS: 2
TOTAL SITE SF: 23,678 SQ. FT.
TOTAL SQUARE FOOTAGE: 11466 SQ.
OWNER: MERIBEL CORPORATION
225 WALL ST, SUITE 2005
VAIL, CO 81657-3615
P: 970.476.4006
ARCHITECT: BILL PIERCE, PRINCIPAL IN CHARGE
PIERCE ARCHITECTS
1650 E. VAIL VALLEY DRIVE, C1
VAIL, COLORADO 81657
P: 970.476.6342
F: 970.476.4901
E: bill@vailarchitects.com
CONTRACTOR: GE JOHNSON
SUPERINTENDENT: ANDY SANDOVAL
P: 719.473.5324
M: 970.376.2523
E: sandovala@gejohnson.com
STRUCTURAL ENGINEER: JVA
CRAIG M. KOBE, P.E.
P: 303.565.4964
E: ckobe@jvajva.com
MECHANICAL ENGINEER: BEAUDIN GANZE
ERIN PASOLD, P.E.
P: 970.949.6108, ext. 2244
E: elpasold@bgce.com
OWNER'S REP OAC MANAGEMENT, INC.
ERIK PETERSON
P: 970.390.0164
E: erikpeterson@oacminc.com
LEGAL DESCRIPTION OF PROPERTY:
Situs Address 000182 W MEADOW DR
Tax Area SC103 - VAIL (TOWN) - SC103
Parcel Number 2101-071-01-006
Legal Summary Subdivision: VAIL
VILLAGE FILING 2 Lot: 5
182 WEST MEADOW DRIVE
VAIL, CO 81657
04/15/15