HomeMy WebLinkAboutA0-03 - LIFE SAFETY.pdfMAX. EXIT SEPERATION 99'-5" M A X . E X I T S E P E R A T I O N 9 4 '-3 " EGRESSABLE DOORS EXIT EXIT EXIT EXIT EGRESSABLE DOORS MAX. EXIT SEPERATION 65'-11" EGRESSABLE DOORS EGRESSABLE DOORS EGRESSABLE DOORS EGRESSABLE WINDOWS EGRESSABLE WINDOWS MAX. EXIT SEPERATION 80'-8 1/8" PLAN NORTH TRUE NORTH EGRESSABLE WINDOW WELLS EGRESSABLE WINDOW WELL EXIT EXIT M A X . E X IT S E P E R A T I O N 7 3'-5 1 /4 " MAX. EXIT SEPERATION 74'-3 1/2" MAX EXIT SEPARATION EGRESS LEGEND MAX EXIT TRAVEL PATH OF EGRESS FIRE SAFETY GENERAL NOTES - ALL BEDROOMS TO HAVE EGRESSABLE WINDOWS OR DOORS. - ENTIRE STRUCTURE WILL HAVE A FIRE SPRINKLER SYSTEM TOTAL SQUARE FOOTAGE OVERVIEW UNIT A 2305 SQ FT 1ST FLOOR 2ND FLOOR BASEMENT TOTAL SF UNIT B 2425 SQ FT 1668 SQ FT 1920 SQ FT TOTAL SF 4730 SQ FT 3588 SQ FT 1532 SQ FT 1596 SQ FT 3128 SQ FT 5505 SQ FT 5941 SQ FT 11446 SQ FT - DUPLEX TO HAVE AUTOMATED FIRE SPRINKLER SYSTEM, BY OTHERS. - DUPLEX TO HAVE AUTOMATED, MONITORED FIRE ALERT SYSTEM, BY OTHERS. - FIRE PROVENTION SYSTEMS TO COMPLY WITH VFES STANDARDS AND GUIDELINES. GENERAL FIRE SAFETY NOTES: 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 A0.03 LIFE SAFETY MERIBEL CORPORATION Project Number - 1428 02/09/15 CD SET 1/16" = 1'-0" 1 MAIN FLOOR A/B - LIFE SAFETY 1/16" = 1'-0" 2 SECOND FLOOR A/B - LIFE SAFETY 1/16" = 1'-0" 3 BASEMENT - LIFE SAFETY OCCUPANCY GROUP: RESIDENTIAL (R-2) TOTAL FLOOR AREA: 11446 SF UNIT SF: UNIT A: 5941 SF UNIT B: 5505 SF OCCUPANT LOAD: RESIDENTIAL (R-2) - (TWO DWELLING UNITS) RESIDENTIAL AREAS = 200 GROSS UNIT A = 5941 SF 5941/200= 30 OCCUPANTS UNIT B = 5505 SF 5505/200= 28 OCCUPANTS NO. OF OCCUPANTS = 28-30 PER UNIT UNIT A EGRESS: EGRESS PATH WIDTH REQUIRED: 200 OCCUPANTS X .3 = 60" 60" / 3 EXITS = 20" MIN. UNIT B EGRESS: EGRESS PATH WIDTH REQUIRED: 200 OCCUPANTS X .3 = 60" 60" / 3 EXITS = 20" MIN. EGRESS PATH WIDTH PROVIDED = 60" MIN. COMMON PATH OF EGRESS TRAVEL PERMITTED: 125'-0" MAX. COMMON PATH OF EGRESS TRAVEL PROVIDED: 60'-0" MAX. EXITS REQUIRED = 2 EXIT WIDTH REQUIRED: 200 X .2 = 40"/2 EXITS = 20" MIN. EXITS PROVIDED: UNIT A 1) 3'-0" WIDTH PROVIDED (MAIN) 2) 3'-0" WIDTH PROVIDED (LIVING) 3) 3'-0" WIDTH PROVIDED (MUDROOM) TOTAL: 9'-0" OF EXIT WIDTH PROVIDED UNIT B 1) 3'-0" WIDTH PROVIDED (MAIN) 2) 3'-0" WIDTH PROVIDED (LIVING) 3) 3'-0" WIDTH PROVIDED (MUDROOM) TOTAL: 9'-0" OF EXIT WIDTH PROVIDED OCCUPANT LOAD EXITING EGRESS 04/15/15