HomeMy WebLinkAboutA0-09 - ASSEMBLIES.pdfGENERAL ASSEMBLY AND FINISH SYSTEMS
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not
limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any
discrepancies prior to ordering and installation of product in assembly. All products are to be installed in strict conformance
with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product.
Refer to both architectural and structural drawings for assembly information. Structural drawings shall govern over
architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location
dimensions, fire, sound and weather proofing related details. Contact Architect immediately with any discrepancy prior to
installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following
assembly narratives are general.
WALL SYSTEMS:
RATED ASSEMBLIES (@ MAIN & UPPER LEVELS):
F1-W WOOD PLANK ON GYPCRETE
Wood plank installed per manufacturer's specifications, over 1 1/2" thick light concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 16" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "x"gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
F1-C CARPET ON GYPCRETE
Carpet and pad, installed per manufacturer's specifications, over 1 1/2" thick light weigth concrete underlayment over
1/4" AcoustiMat II underlayment on 3/4" T & G APA rated (exposure 1) wood structural panels over Pre-Manufactured
floor trusses at 24" o.c. maximum spacing (Re: Structural Drawings.) Install (1) layer 5/8" Type "X" gypsum
board ceiling on Resilient Channels 7/8" deep, 26 gauge galvanized steel @ 16"o.c. on U/S of trusses.
ASSEMBLIES (@ BASEMENTS):
F2-W WOOD PLANKS ON CONCRETE SLAB
Wood plank flooring per manufacturer's specifications, over felt underlayment installed per manufacturer's
specifications, over concrete slab.
Provide transitions strips where there is a material change in floor finish.
F2-C CARPET ON CONCRETE SLAB
Carpet per manufacturer's specifications, over carpet underlayment installed per manufacturer's
specifications, over concrete slab.
Provide transitions strips where there is a material change in floor finish.
F2-T TILE ON CONCRETE SLAB
12"x12" Ceramic Tile on thin set mortar on concrete slab.
Provide transitions strips where there is a material change in floor finish.
F2-CT CERAMIC TILE ON CONCRETE SLAB
W" x H" Ceramic Tile (TBD) on thin set mortar over concrete slab.
Provide transitions strips where there is a material change in floor finish.
F2-S STONE ON CONCRETE SLAB
W" x H" Stone (TBD) on thin set mortar over concrete slab.
Provide transitions strips where there is a material change in floor finish.
ASSEMBLIES (@ GARAGE):
F3 CONCRETE SLAB ON GRADE WITH GARAGE FINISH
Structural concrete slab with sloped concrete topping. RE: Structure.
Finish with a garage finish (TBD).
C1 GYPSUM BOARD CEILING CONSTRUCTION
(1Hr-Rated) UL DESIGN NO. L521 & UL P533
5/8" Gypsum board on 7/8" furring channels attached to underside of floor trusses.
(TYPICAL FOR ALL CEILINGS) Note: Typical ceiling system included in floor assemblies. Re: floor assemblies.
C2 W EXPOSED BEAMS WITH T&G CEILING CONSTRUCTION
(Non-Rated)
Exposed rustic beams with rustic T&G inlay.
C2 G EXPOSED BEAMS WITH GYPSUM BOARD CEILING CONSTRUCTION
(Non-Rated)
Exposed rustic beams with gypsum board inlay. Level 4 drywall finish.
CEILING SYSTEMS:
FLOOR SYSTEMS:
Note: Reference structural drawings and specifications for all fasteners within all building assemblies including but not limited to nails, screws & bolts for size (length, diameter & shank), type, style & spacing. Contact Architect with any discrepancies
prior to ordering and installation of product in assembly. All products are to be installed in strict conformance with product specifications, requirements and warranties. Contact Architect with any discrepancies prior to ordering product. Refer to both
architectural and structural drawings for assembly information. Structural drawings shall govern over architectural drawings regarding framing. Architectural drawings shall govern over structural drawings regarding wall location dimensions, fire, sound
and weather proofing related details. Contact Architect immediately with any discrepancy prior to installation of the work. Install all fire rated assemblies per their listings as referenced with options shown. The following assembly narratives are general.
NOTES
* Stone veneer to be installed in strict conformance with ESR Reports (ICC) for manufacturer selected.
Comply with the Rocky Mountain Masonry Institute requirements & specifications for systems not
evaluated by ICC, 2009 International Building Code requirements and industry recognized trade
standards.
** Interior Walls Studs:
4 - 2x4 Wood Studs
6 - 2x6 Wood Studs
8 - 2x8 Wood Studs
RE: See wall tags for stud sizes.
**** Use water and mold resistant non-paper-faced substrate at shower walls and plumbing walls; moisture resistant
non-paper-faced substrate at all other bathroom and restroom walls; water, mold, and indentation resistant
non-paper-faced underlayment for all carpet, vinyl, and tile interior floor covering over slab on grade where
recommended by manufacturer. Maintain required fire-rating.
Refer to Structural Drawings for Bearing Walls and Shear Walls.
RATED ASSEMBLIES (EXTERIOR):
W1-WS WOOD SIDING @ RATED EXTERIOR WALLS
Wood Siding on weather resistive barrier on (1) layer 5/8" gypsum sheathing @
exterior face of 2x8 wood studs w/ R-20 batt insulation between studs. (1) layer 5/8" gypsum board @
interior face of studs. (Re: Structural for size and spacing of studs and sheathing).
W1-MP METAL PANEL @ RATED EXTERIOR WALLS
Metal panels mounted on suspension system per panel manufacturer over weather resistive barrier on (1)
layer structural sheathing per JVA @ exterior face of 2x8 wood studs w/ R-20 batt insulation between studs.
(1) layer 5/8" gypsum board @ interior face of studs. (Re: Structural for size and spacing of studs and
sheathing).
RATED ASSEMBLIES (EXTERIOR):
W2 GYPSUM SHEATHING @ RATED INTERIOR GARAGE SEPARATION WALLS
(1-Hr. Fire Rated Assembly UL Design No. U356)
(1) layer 5/8" Type "X" gypsum sheathing @ garage interior face of 2x6 wood studs w/ R-20 batt insulation
between studs. (1) layer 5/8" gypsum board @ non-garage face of studs. (Re: Structural for size and spacing of
studs and sheathing).
W3 GYPSUM SHEATHING @ UNIT SEPARATION WALLS
(2-Hr. Fire Rated Assembly UL Design No. Uxxxx)
PARTY WALL - (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6 wood studs w/ R-20 batt
insulation between studs. 1" air cavity. (1) layer 5/8" Type "X" gypsum sheathing @ both sides of 2x6
wood studs w/ R-20 batt insulation between studs.
NON-RATED ASSEMBLIES (INTERIOR):
W4-*** GYPSUM BOARD PARTITION ON 2 x WOOD STUDS
(Non-Rated)
(1) Layer 5/8" gypsum board**** on each side of 2x wood studs at non-bearing walls demising bedrooms
and living areas. Sound batt insulation. (Re. Structural for size and spacing).
W5- GYPSUM BOARD OVER FURRING
(Non-Rated)
(1) Layer 5/8" gypsum board**** over 1 1/2" metal furring strips @ 16" O.C. with 1 1/2" rigid insulation.
(Re. Structural for size and spacing).
(1Hr-Rated), R-50
R1 SYNTHETIC SHAKE SHINGLE ROOF CONSTRUCTION:
(1-Hr. Fire Rated Assembly UL P533)
50 year composite shingle (min. Class A, ASTM E 108) roofing on 30 lb. felt weather barrier (ice and
water shield to cover entire roof) on 15/32" APA rated structural deck sheathing (U.N.O. on Structural
Drawings) over 1 layer structural sheathing over 2x10 dimensional lumber perlins. Perlins to sit on 2x4
spacer. 2x4 spacer to be centered on timber rafters. See Sheet A5.02. (Re. Structural for size and spacing).
110 MPH Wind resistance (ASTM D 3161), Class 4 impact resistance (UL 2218), ICC-ES (ESR-2119),
Miami Dade Code Approval
ROOF SYSTEMS:
2X8 DIMENSIONAL
LUMBER @ 16" O.C.
5/8" GYPSUM
WALL BOARD
INTERIOR
WOOD SIDING
EXTERIOR
BATT INSULATION,
R-20 MIN.
BUILDING WRAP
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-S1
5/8" GYP. = 40 MIN.
2x8 FRAMING @ 16"
O.C.= 20 MIN.
BATT INSULATION = 15 MIN.
FIRE RATING
(1-HOUR MIN.) :
SHEATHING = 20 MIN.
WALL ASSEMBLIES
EXTERIOR WALL ASSEMBLIES:
INTERIOR WALL ASSEMBLIES:
NOTE: ALL EXTERIOR WALLS TO HAVE A FIRE RATING OF 1 HOUR
MINIMUM. STRUCTURE TO HAVE FIRE SPRINKLER SYSTEM.
FIRE RATED ASSEMBLIES:
NON-RATED ASSEMBLIES:
NON-RATED ASSEMBLIES @ FOUNDATION WALLS:
5/8" GYPSUM
WALL BOARD
0'-3 1/2"
W4-4
2X4 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
5/8" GYPSUM
WALL BOARD
0'-5 1/2"
W4-6
2X6 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
SOUND BATTS
2X8 DIMENSIONAL LUMBER
@ 16" O.C., SEE PLANS AND
WALL TAG FOR LUMBER SIZE, TYP.
5/8" GYPSUM
WALL BOARD
0'-7 1/4"
W4-8
SOUND BATTS
5/8" GYPSUM
WALL BOARD,
TYPE X, TYP.
5 1/2" 1 1/2"
W2
2X6 DIMENSIONAL LUMBER
@ 16" O.C.,TYP.
1 1/4" 1 1/2" 5 1/2" 1"
1" AIR CAVITY, TYP.
BATT INSULATION, TYP.
5/8" GYP. = 40 MIN. X6
FIRE RATED: 2 HOUR MIN.
2x8 FRAMING (X2) @ 16" O.C.= 20 MIN. X2
BATT INSULATION = 15 MIN. X2
FIRE RATING
(2-HOUR MIN.) :
7/8" RESILIENT CHANNEL, TYP.
5/8" GYPSUM
WALL BOARD,
TYPE X, TYP.
0'-5 1/2"
W3
2X6 DIMENSIONAL LUMBER
@ 16" O.C.,TYP.
BATT INSULATION, TYP.
5/8" GYP. = 40 MIN. x2
FIRE RATED: 1 HOUR MIN.
2x8 FRAMING (X2) @ 16" O.C.= 20 MIN.
BATT INSULATION = 15 MIN.
FIRE RATING
(1-HOUR MIN.) :
INTERIOR GARAGE
FOUNDATION WALL,
RE: STRUCTURE, TYP.
5/8" GYPSUM
WALL BOARD
W5
1 1/2" METAL FURRING
@ 16" O.C., TYP.
1 1/2" RIGID INSULATION
BETWEEN FURRING, TYP.
2X8 DIMENSIONAL
LUMBER @ 16" O.C.
5/8" GYPSUM
WALL BOARD
INTERIOR
WOOD SIDING,
ALTERNATE COLOR
EXTERIOR
BATT INSULATION,
R-20 MIN.
BUILDING WRAP
STRUCTURAL SHEATHING,
RE: STRUCTURE
W1-S2
5/8" GYP. = 40 MIN.
2x8 FRAMING @ 16"
O.C.= 20 MIN.
BATT INSULATION = 15 MIN.
FIRE RATING
(1-HOUR MIN.) :
SHEATHING = 20 MIN.
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
A0.09
ASSEMBLIES
MERIBEL CORPORATION
Project Number - 1428
03/11/15
CD SET
3" = 1'-0"
1
W1-S1 - WOOD SIDING
1 1/2" = 1'-0"
5
INTERIOR PARTITION (2X4) W4-4
1 1/2" = 1'-0"
6
INTERIOR PARTITION (2X6) W4-6
1 1/2" = 1'-0"
7
INTERIOR PARTITION (2X8) W4-8
1 1/2" = 1'-0"
3
INTERIOR UNIT SEPARATION W2
1 1/2" = 1'-0"
4
GARAGE SEPARATION W3
1 1/2" = 1'-0"
8
INTERIOR FINISH - W-5
3" = 1'-0"
9
W1-S2 - WOOD SIDING (ALT. COLOR)
04/15/15