HomeMy WebLinkAboutA4-00 - ENLARGED PLANS - GENERAL.pdf2
A4.00
3
A4.00
SLOPE TO
DRAIN
9 1/2"
4'-0 5/8" 9 1/2" 3'-10 1/2" 9 1/2"
A4.00
5
2'-4"
7'-0"
RIBBON OUTDOOR, LOD48
4'-0"
SPARK - RIBBON OUTDOOR
SYSTEM (LOD48)
BRONZE REFLECTIVE
TEMPERED FIRE GLASS
AROUND BURNER
STONE OR CONCRETE CAP,
COLOR TO MATCH SIDING
(ALT. COLOR)
SPARK - RIBBON OUTDOOR
SYSTEM (LOD48)
WOOD SIDING
ALTERNATE COLOR
7'-0"
2'-4"
3 1/2"
STONE OR CONCRETE CAP,
COLOR TO MATCH SIDING
(ALT. COLOR)
BASEMENT
8133' - 10"
MAIN FLOOR A/B
8145' - 8"
T.O. RAFT
8131' - 6"
A.1
B
2
A4.00
9'-2 3/8"
4'-11 5/8"
14.66 SF EGRESS
OPENING PROVIDED
(5.7 SF MIN. REQUIRED)
RE: PLANS FOR
WINDOW SWING
- EGRESS LADDER,
TYP. @ ALL WINDOW
WELLS
- FIRST RUNG TO BE
1'-6" MAX. FROM
FINISH SURFACE
- LADDER RUNGS TO
BE SPACED @ 1'-0"
WINDOW WELL
DRAIN, TYP.
CONCRETE
FOUNDATION WALL,
RE: STRUCTURE
WOOD SIDING TO
MATCH EXTERIOR 9'-10" 2'-0"
WINDOW WELL LIGHT @
1843'-8" TO CENTER OF
LIGHT, CENTER LIGHT
ON WINDOW
BASEMENT
8133' - 10"
MAIN FLOOR A/B
8145' - 8"
T.O. RAFT
8131' - 6"
3
A4.00
- EGRESS LADDER, TYP. @
ALL WINDOW WELLS
- FIRST RUNG TO BE 1'-6"
MAX. FROM FINISH SURFACE
- LADDER RUNGS TO BE
SPACED @ 1'-0"
- WINDOW WELL
DRAIN, TYP.
CONCRETE
FOUNDATION WALL,
RE: STRUCTURE
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
A4.00
ENLARGED
PLANS -
GENERAL
MERIBEL CORPORATION
Project Number - 1428
02/09/15
CD SET
1/2" = 1'-0"
4
ENLARGED OUTDOOR FIREPLACE PLAN
1/2" = 1'-0"
5
OUTDOOR FIREPIT ELEVATION
1/2" = 1'-0" 3
WINDOW WELL SECTION 2
1/2" = 1'-0"
2
WINDOW WELL SECTION 1
ENLARGED WINDOW WELL PLANS
WINDOW WELL NOTES:
- PLANS TYPICAL FOR ALL WINDOW
WELLS
- WINDOW WELLS TO CONFORM TO THE
2012 IRC GUIDLINES
- RE: MEP/CIVIL FOR WINDOW WELL
DRAINAGE
ENLARGED OUTDOOR FIREPLACE PLANS
GENERAL NOTES FOR OUTDOOR FIREPLACE:
- GAS LINES SERVING THE OUTDOOR FIREPLACE SHALL NOT
EXCEED 3/4" DIAMETER, RE: MEP
- AUTOMATIC SHUT-OFF TIMER TO BE INSTALLED, 30 MINUTE MAX.
RE: DIAGRAM C, SHEET M4.01
04/15/15