HomeMy WebLinkAboutA6-02 - WINDOW SCHEDULE.pdfSTYLE B
STYLE A
8" 4'-0" 8"
SEE PLANS FOR
SWING DIRECTION
FLOUNDATION
WALLS, RE:
STRUCTURAL
WINDOW
WELL
STYLE C
SLIDING
GLASS
DOOR
7'-0"
7'-2 1/2"
7'-0"
S10
S9
7'-11"
7'-10 5/8"
8'-11 1/2"
S7 S8
12'-0"
8'-11 1/2"
S6
8'-11 1/2"
12'-0"
S5
8'-11 1/2"
S3
10'-0"
S4
10'-0"
8'-0"
S2B 10'-0"
18'-0 3/4"
S1A
17'-4"
10'-0"
S13
S11
S12
6'-4 3/4"
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
A6.02
WINDOW
SCHEDULE
MERIBEL CORPORATION
Project Number - 1428
03/11/15
CD SET
1/2" = 1'-0"
WINDOW SCHEDULE
WINDOW SCHEDULE
MARK WINDOW STYLE WIDTH HEIGHT
HEAD
HEIGHT SILL HEIGHT MANUFACTURER MODEL LOCATION UNIT
1 A 3' - 0" 3' - 0" 18' - 4 3/4" 15' - 4 3/4" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
2 A 3' - 0" 3' - 0" 18' - 4 3/4" 15' - 4 3/4" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
3 A 3' - 0" 3' - 0" 18' - 4 3/4" 15' - 4 3/4" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
4 A 3' - 0" 8' - 0 1/4" 15' - 4 3/4" 7' - 4 1/2" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
5 A 3' - 0" 5' - 10 1/2" 15' - 4 3/4" 9' - 6 1/4" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
6 A 3' - 0" 3' - 9 1/4" 15' - 4 3/4" 11' - 7 1/2" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
7 A 3' - 0" 3' - 0" 4' - 6" 1' - 6" JELD-WEN STAIR ELEVATION (NORTH) UNIT A UNIT A
8 A 3' - 0" 3' - 0" 18' - 4 3/4" 15' - 4 3/4" JELD-WEN STAIR ELEVATION (EAST) UNIT A UNIT A
9 A 3' - 0" 8' - 0 1/4" 15' - 4 3/4" 7' - 4 1/2" JELD-WEN STAIR ELEVATION (EAST) UNIT A UNIT A
10 A 3' - 0" 3' - 0" 4' - 6" 1' - 6" JELD-WEN STAIR ELEVATION (EAST) UNIT A UNIT A
11 A 2' - 6" 9' - 0" 9' - 8" 0' - 8" JELD-WEN ENTRY HALLWAY UNIT B
12 A 2' - 6" 9' - 0" 9' - 8" 0' - 8" JELD-WEN ENTRY HALLWAY UNIT B
13 A 2' - 6" 9' - 0" 9' - 8" 0' - 8" JELD-WEN ENTRY HALLWAY UNIT B
14 A 2' - 6" 5' - 0" 5' - 6" 0' - 6" JELD-WEN UPPER HALLWAY UNIT B
15 A 2' - 6" 5' - 0" 5' - 6" 0' - 6" JELD-WEN UPPER HALLWAY UNIT B
16 A 2' - 6" 5' - 0" 5' - 6" 0' - 6" JELD-WEN UPPER HALLWAY UNIT B
17 A 3' - 0" 5' - 9" 9' - 0" 3' - 3" JELD-WEN BEDROOM 3 UNIT B
18 A 7' - 0" 5' - 9" 9' - 0" 3' - 3" JELD-WEN BEDROOM 3 UNIT B
22 A 3' - 6" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
23 A 3' - 6" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
25 A 3' - 7 3/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
26 A 3' - 7 3/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
27 A 3' - 7 3/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
28 A 3' - 7 3/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
29 A 5' - 0" 5' - 9" 9' - 0" 3' - 3" JELD-WEN BEDROOM 3 UNIT B
30 A 5' - 0" 5' - 9" 9' - 0" 3' - 3" JELD-WEN BEDROOM 3 UNIT B
31 A 2' - 0" 6' - 0" 9' - 0" 3' - 0" JELD-WEN MASTER BEDROOM OFFICE UNIT A
32 A 2' - 0" 6' - 0" 9' - 0" 3' - 0" JELD-WEN MASTER BEDROOM OFFICE UNIT A
33 A 3' - 6" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
35 A 3' - 0" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
36 A 3' - 0" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM A UNIT A
37 A 3' - 4" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
38 A 3' - 4" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM A UNIT A
39 A 3' - 4" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
40 A 3' - 4" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM A UNIT A
41 A 3' - 4" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
42 A 3' - 4" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM A UNIT A
43 A 3' - 5 5/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
44 A 3' - 5 5/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
45 A 3' - 5 5/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
46 A 3' - 5 5/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
47 A 3' - 2 1/4" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
51 A 4' - 6" 2' - 0" 8' - 6" 6' - 6" JELD-WEN MASTER BATH UNIT B
52 A 3' - 4 1/2" 1' - 9 1/2" 10' - 0 1/4" 8' - 2 3/4" JELD-WEN LIVING ROOM B UNIT B
54 A 3' - 4 1/2" 1' - 9 1/2" 10' - 0 1/4" 8' - 2 3/4" JELD-WEN LIVING ROOM B UNIT B
56 B 3' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN BUNKROOM (BASEMENT) UNIT B
57 B 3' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN BUNKROOM (BASEMENT) UNIT B
58 B 3' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN BUNKROOM (BASEMENT) UNIT B
59 B 2' - 9" 5' - 0" 8' - 0" 3' - 0" JELD-WEN BUNKROOM (BASEMENT) UNIT B
60 B 3' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN BUNKROOM (BASEMENT) UNIT B
61 A 3' - 0" 8' - 8 1/2" 9' - 2 1/2" 0' - 6" JELD-WEN UPPER HALLWAY UNIT A
62 A 3' - 0" 8' - 8 1/2" 9' - 2 1/2" 0' - 6" JELD-WEN UPPER HALLWAY UNIT A
63 A 3' - 0" 8' - 8 1/2" 9' - 2 1/2" 0' - 6" JELD-WEN UPPER HALLWAY UNIT A
64 A 2' - 0" 4' - 0" 8' - 0" 4' - 0" JELD-WEN KITCHEN UNIT B
65 A 2' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN MASTER BEDROOM OFFICE UNIT B
66 A 2' - 0" 5' - 0" 8' - 0" 3' - 0" JELD-WEN MASTER BEDROOM OFFICE UNIT B
67 A 4' - 6" 2' - 0" 7' - 0" 5' - 0" JELD-WEN MASTER BATH UNIT B
68 A 3' - 0" 3' - 0" 5' - 8" 2' - 8" JELD-WEN BEDROOM 3 UNIT B
70 A 3' - 7 3/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM B UNIT B
71 A 3' - 7 3/8" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM B UNIT B
72 A 3' - 5 5/8" 1' - 9 1/2" 10' - 0" 8' - 2 1/2" JELD-WEN LIVING ROOM A UNIT A
73 A 3' - 5 5/8" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" TBD LIVING ROOM A UNIT A
74 A 3' - 4" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM A UNIT A
75 A 3' - 4" 1' - 9 1/2" 7' - 9 1/2" 6' - 0" JELD-WEN LIVING ROOM A UNIT A
76 A 3' - 2 1/4" 1' - 9 1/2" 7' - 9 1/2" 6' - 0" JELD-WEN LIVING ROOM A UNIT A
77 A 3' - 6" 1' - 9 1/2" 7' - 9 1/2" 6' - 0" JELD-WEN LIVING ROOM A UNIT A
78 A 3' - 6" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM B UNIT A
79 A 3' - 6" 7' - 11 1/2" 8' - 2 1/2" 0' - 3" JELD-WEN LIVING ROOM B UNIT A
1/4" = 1'-0"
4
UNIT B BEDROOM 3 & 4 - SECOND
FLOOR
1/4" = 1'-0"
1
UNIT A BEDROOM 3 & 4 - SECOND
FLOOR
3/16" = 1'-0"
6
UNIT A - MASTER 2A
3/16" = 1'-0"
3
UNIT A - MASTER 1A
3/16" = 1'-0"
2
UNIT B - MASTER 1B
3/16" = 1'-0"
5
UNIT B - MASTER 2B
SLIDING GLASS DOORS
SLIDING GLASS DOOR SCHEDULE
DOOR # LOCATION UNIT
DOOR/WINDO
W STYLE WIDTH HEIGHT PANEL TYPE HARDWARE PACKAGE COMMENTS
S1A LIVING ROOM A UNIT A C 13' - 10 3/8" 8' - 2 1/2"
S2B LIVING ROOM B UNIT B C 14' - 5 3/8" 8' - 2 1/2"
S3 MASTER BEDROOM 1B UNIT B C 10' - 0 5/16" 8' - 11 1/2"
S4 MASTER BEDROOM 2B UNIT B C 10' - 0 5/16" 7' - 11 1/2"
S5 MASTER BEDROOM 1A UNIT A C 12' - 0 5/16" 8' - 11 1/2"
S6 MASTER BEDROOM 2A UNIT A C 12' - 0 5/16" 8' - 11 1/2"
S7 BEDROOM 2A UNIT A C 7' - 11 5/8" 9' - 0"
S8 BEDROOM 3A UNIT A C 7' - 11 5/8" 9' - 0"
S9 BEDROOM 2B UNIT B C 7' - 1" 7' - 3"
S10 BEDROOM 3B UNIT B C 7' - 1" 7' - 3"
S11 UNIT A - SLIDER @ DINING AREA UNIT A C 7' - 0" 8' - 2 1/2"
S12 UNIT A - SLIDER @ LIVING ROOM UNIT A C 6' - 4 1/2" 8' - 2 1/2"
S13 UNIT B SLIDER @ LIVING ROOM UNIT B C 6' - 9" 8' - 2 1/2"
3/16" = 1'-0"
7
UNIT B LIVING ROOM - SOUTH
ELEVATION
3/16" = 1'-0"
8
UNIT A LIVING ROOM - SOUTH
ELEVATION
3/16" = 1'-0"
9
UNIT B - SLIDER
3/16" = 1'-0"
10
UNIT A - SLIDER
3/16" = 1'-0"
11
UNIT A SLIDER 2
04/15/15