Loading...
HomeMy WebLinkAboutB14-0344 Blower Door Test.pdf Page 1 of 1 10/28/2015 P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com 182 W. Meadow Drive Unit A Final Blower Door Report Test Date: October 22, 2015 Builder: GE Johnson Contact: Eddy Cotton Site Address: 182 W. Meadow Drive Unit A, Vail Testing By: Kristen Hartel HERS Rating Company: Active Energies Background The project goal is to undergo testing at final construction to determine if the project meets code requirements for air leakage (3ACH50) and identify any weak areas or difficult details for correction. Active Energies was contracted to perform a rough blower door test and thermal infrared imaging to determine identify any areas of improvement prior to final construction. Site Observations A final Blower Door test was completed for the residence the located at 182 W. Meadow Drive, Unit A. Construction was complete. Blower Door Test Air leakage The home was depressurized to the standard -50 Pa of pressure, and a leakage of 3,165 CFM@50 was projected. The ACH50, the rating used by the Town of Vail building code and requirements, was calculated to be 2.86. Please call with any questions or concerns. Thank you. Kristen Hartel Active Energies, Inc. 970-306-4248 Kristen@ActiveEnergies.com www.activeenergies.com