HomeMy WebLinkAboutB14-0344 Blower Door Test.pdf
Page 1 of 1 10/28/2015
P.O. Box 7627, Avon, CO 81620 | P: 970.306.4233 | F: 866.403.3485 | www.activeenergies.com
182 W. Meadow Drive Unit A
Final Blower Door Report
Test Date: October 22, 2015
Builder: GE Johnson
Contact: Eddy Cotton
Site Address: 182 W. Meadow Drive Unit A, Vail
Testing By: Kristen Hartel
HERS Rating Company: Active Energies
Background
The project goal is to undergo testing at final construction to determine if the project meets code
requirements for air leakage (3ACH50) and identify any weak areas or difficult details for
correction. Active Energies was contracted to perform a rough blower door test and thermal
infrared imaging to determine identify any areas of improvement prior to final construction.
Site Observations
A final Blower Door test was completed for the residence the located at 182 W. Meadow Drive,
Unit A. Construction was complete.
Blower Door Test
Air leakage
The home was depressurized to the standard -50 Pa of pressure, and a leakage of 3,165
CFM@50 was projected.
The ACH50, the rating used by the Town of Vail building code and requirements, was calculated
to be 2.86.
Please call with any questions or concerns. Thank you.
Kristen Hartel
Active Energies, Inc.
970-306-4248
Kristen@ActiveEnergies.com
www.activeenergies.com