Loading...
HomeMy WebLinkAboutB14-0344 Special Inspection Reports.pdfWest Slope Testing & Inspection LLC 3 I 77 Glendam Dr. Grand Junction, CO 8I504 Phone:970-434-6988 Cell: 970-260-2844 Dates: 3-20-15 & 3-26-15 Inspection Report Client: HP Geotech (Job #HP 114 043B) Project: I82 West Meadow Dr. Duplex Address: I82 West Meadow Dr. Vail, CO Building Permit No: BI 4-0344 General Contractor: GE Johnson Inspection of shop fabrication or field work at job site: Field Report #I Page I of I Report: Verified onsite welders were qualified per A WS D l. I & using the correct welding electrodes/materials. Visually inspected field welding at face plate connections (for anchoring steel beams to concrete wall pockets), and inspected high strength A325 bolting at steel beam & column connections main floor level framing both units. Visually inspected field welding at steel frame moment connections upper level framing grid line I at A. I & C. Also observed joint preparation for steel frame moment welds grid line 5 at B. I & C.9 (note double bevel groove welds with back gouging/grinding were going to be used at these connections in lieu of single bevel welds with backing bars. Both weld joints are prequalified per A WS D 1.1 for complete joint penetration welds). Inspected high strength A325 bolting at steel beam & column connections upper level framing grids I to 2 West unit. The field welding & high strength A325 bolting inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the AWS DI.I Structural Welding Code & the AISC/RCSC Specification for A325/A490 bolting. Further inspections will be performed as work progresses. Inspectorffechnician: Douglas E Young West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone:970-434-6988 Cell: 970-260-2844 Dates: 4-2-15 & 4-14-15 Inspection Report Client: HP Geotech (Job #HP 114 043B) Project: 182 West Meadow Dr. Duplex Address: 182 West Meadow Dr. Vail, CO Building Permit No: B14-0344 General Contractor: GE Johnson Inspection of shop fabrication or field work at job site: Field Report#2 Page 1of1 Report: Visually inspected field welding at steel frame moment connections upper level framing grid line 5 at B.1 & C.9, and grid line E.4 at E2 & H. Visually inspected field welding at tube steel connection welds & column base weld main level framing grid line A from 2 to 3. Inspected high strength A325 bolting at steel beam & column connections upper level framing grids 2 to 5 West unit, and 1.8 to 4 East Unit. The field welding & high strength A325 bolting inspected above appeared to be in substantial conformance with the plans, and the quality requirements of the A WS D 1.1 Structural Welding Code & the AISC/RCSC Specification for A325/ A490 bolting. Further inspections will be performed on remainder of project. Inspectorffechnician: Douglas E Young + Douglas E Young CWI 96070131 QC1 EXP. 7/1/2017 West Slope Testing & Inspection LLC 3177 Glendam Dr. Grand Junction, CO 81504 Phone:970-434-6988 Cell: 970-260-2844 Date: 5-5-15 Inspection Report Client: HP Geotech (Job #HP 114 043B) Project: 182 West Meadow Dr. Duplex Address: 182 West Meadow Dr. Vail, CO Building Permit No: Bl4-0344 General Contractor: GE Johnson Inspection of shop fabrication or field work at job site: Field Report#3 Page 1of1 Report: Received/reviewed certificates of compliance for high strength A325 bolts, nuts, and washers used on the project. Inspected high strength A325 bolting at steel beam & column connections upper level framing grids D to E between 5 & 6. The high strength A325 bolting inspected above appeared to be in substantial conformance with the plans, and the requirements of the AISC/RCSC Specification for A325/A490 bolting. Further inspections will be performed on remainder of project. West Slope Testing & Inspection LLC Report#4 3177 Glendam Dr. Grand Junction, CO 81504 Phone:970-434-6988 Cell: 970-260-2844 Page 1of1 Final Inspection Report Date: 7-9-15 Client: HP Geotech (Job #HP 114 043B) Project: 182 West Meadow Dr. Duplex Address: 182 West Meadow Dr. Vail, CO Building Permit No: B 14-0344 General Contractor: GE Johnson Inspection of shop fabrication or field work at job site: Field Report: Visually inspected field welding at shear plates to W12x35 steel beam unit B upper level framing grid line A.1 between grids 1 & 1.1 frame RF 4. Also visually inspected field welding at tube steel connections South screen wall to unit B, and field welding at steel stair stringer connection top of stairs Unit B. The field welding inspected above appeared to be in substantial conformance with the latest plans, and the quality requirements of the A WS D 1.1 Structural Welding Code. To the best of my knowledge this completes the special inspections of the structural steel onsite welding & high strength A325 bolting on the project, as outlined in reports #1 thru #4. Douglas Young cwt 96010131 OC1 EXP. 71112017