Loading...
HomeMy WebLinkAboutBegin_Workflow - Review Comments - 10-07-2014_14-35-46.pdfBegin_Workflow ­ Review Comments ­ 10­07­2014_14­35­46 Review Cycle Department Markup Snapshot 1 Building File: A0­00 ­ COVER.pdf ChangeMark: jmondragon Description: building 002 Comment: please provide a complete Res Check for code compliance 1 Building File: A0­00 ­ COVER.pdf ChangeMark: JR Description: building 009 Comment: blower door test required comments are typical for both sides 1 Building File: A1­04 ­ BASEMENT FLOOR PLAN.pdf ChangeMark: jmondragon Description: building 003 Comment: provide egress from this area considered for sleep[ing purposes (closet) 1 Building File: A3­02 ­ BUILDING SECTIONS.pdf ChangeMark: jmondragon Description: building 004 Comment: provide egress code compliance provide window well plan 1 Building File: A3­03 ­ WALL SECTIONS.pdf ChangeMark: jmondragon Description: building 006 Comment: provide ladder detail  1 Building File: A6­02 ­ WINDOW SCHEDULE.pdf ChangeMark: jmondragon Description: building 007 Comment: provide u values and res check 1 Building File: S5 ­ FOUNDATION SECTIONS.pdf ChangeMark: jmondragon Description: building 008 Comment: provide radon details (barrier) and piping layout 1 Public Works File: A0­05 ­ TOPOGRAPHICAL SURVEY.pdf ChangeMark: tkassmel Description: PW001 Comment: Need to submit a stamped survey from a licensed surveyor. 1 Public Works File: C2 ­ GRADING & EROSION CONTROL PLAN.pdf ChangeMark: tkassmel Description: PW001 Comment: Remove improvements from Town of Vail Property/Streamtract 1 Public Works File: C2 ­ GRADING & EROSION CONTROL PLAN.pdf ChangeMark: tkassmel Description: PW002 Comment: Concrete Pan is not required. There is already a 2' pan on north side of paver walk. 1 Public Works File: C2 ­ GRADING & EROSION CONTROL PLAN.pdf ChangeMark: tkassmel Description: PW003 Comment: Proposed swales should not discharge onto neighbors property. Show grading. 1 Public Works File: C5.1 ­ FOUNDATION DRAIN PLAN.pdf ChangeMark: tkassmel Description: PW001 Comment: Remove improvements from Town of Vail Property/Streamtract 1 Public Works File: K__1428 ­ Eagle Valley Survey 182 WMD.pdf ChangeMark: tkassmel Description: PW001 Comment: Flooplain Lines cannot be scaled. They need to be placed based on the adopted FEMA floodplain profiles. Please place the floodplain on the survey correctly. 1 Public Works File: K__1428 ­ Eagle Valley Survey 182 WMD.pdf ChangeMark: tkassmel Description: PW002 Comment: We need a signed and stamped survey.