HomeMy WebLinkAboutcompliance-report-20140903_125501_626.pdfInspection Checklist
Requirements: 100.0% were addressed directly in the REScheck software
REScheck Software Version 4.5.0
Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each
requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception
is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided.
Energy Code: 2012 IECC
Section
#
& Req.ID
Pre-Inspection/Plan Review
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
103.1,
103.2,
403.7
[PR3]1
Construction drawings and
documentation demonstrate
energy code compliance for
lighting and mechanical systems.
Systems serving multiple
dwelling units must demonstrate
compliance with the IECC
Commercial Provisions.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
302.1,
403.6
[PR2]2
Heating and cooling equipment is
sized per ACCA Manual S based
on loads calculated per ACCA
Manual J or other methods
approved by the code official.
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Heating:
Btu/hr_____
Cooling:
Btu/hr_____
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive
Duplex\Engineering\951100MEP.rck
Page 2 of 6
09/03/14
Report date:
03/04/15
2012 IECC Foundation Inspection Complies? Comments/Assumptions
403.8
[FO12]2
Snow- and ice-melting system controls
installed.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive
Duplex\Engineering\951100MEP.rck
Page 3 of 6
09/03/14
Report date:
03/04/15
Section
#
& Req.ID
Framing / Rough-In Inspection
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
403.2.1
[FR12]1
Supply ducts in attics are
insulated to ≥R-8. All other ducts
in unconditioned spaces or
outside the building envelope are
insulated to ≥R-6.
R-_____
R-_____
R-_____
R-_____
Complies
Does Not
Not Observable
Not Applicable
Exception: Ducts located
completely inside the
building envelope.
403.2.2
[FR13]1
All joints and seams of air ducts,
air handlers, and filter boxes are
sealed.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.2.3
[FR15]3
Building cavities are not used as
ducts or plenums.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.3
[FR17]2
HVAC piping conveying fluids
above 105 ºF or chilled fluids
below 55 ºF are insulated to ≥R-
3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.3.1
[FR24]2
Protection of insulation on HVAC
piping.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.4.2
[FR18]2
Hot water pipes are insulated to
≥R-3.
R-_____ R-_____ Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive
Duplex\Engineering\951100MEP.rck
Page 4 of 6
09/03/14
Report date:
03/04/15
Section
#
& Req.ID
Final Inspection Provisions
Plans Verified
Value
Field Verified
Value
Complies? Comments/Assumptions
403.2.2
[FI4]1
Duct tightness test result of <=4
cfm/100 ft2 across the system or
<=3 cfm/100 ft2 without air
handler @ 25 Pa. For rough-in
tests, verification may need to
occur during Framing Inspection.
_____ cfm/100
ft2
_____ cfm/100
ft2
Complies
Does Not
Not Observable
Not Applicable
Exception: All ducts and air
handlers are located within
conditioned space.
403.2.2.1
[FI24]1
Air handler leakage designated
by manufacturer at <=2% of
design air flow.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.1.1
[FI9]2
Programmable thermostats
installed on forced air furnaces.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
403.1.2
[FI10]2
Heat pump thermostat installed
on heat pumps.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
403.4.1
[FI11]2
Circulating service hot water
systems have automatic or
accessible manual controls.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.5.1
[FI25]2
All mechanical ventilation system
fans not part of tested and listed
HVAC equipment meet efficacy
and air flow limits.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
403.9.1
[FI12]3
Readily accessible switch on
heaters for swimming pools or
permanent in-ground spas.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
Location on plans/spec:
By others.
403.9.2
[FI19]3
Timer switches on heaters and
pumps serving pools and
permanent spas.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
Location on plans/spec:
By others.
403.9.3
[FI20]3
Heated pools and permanent
spas have a vapor retardant
cover.
Complies
Does Not
Not Observable
Not Applicable
Exception: Requirement is
not applicable.
Location on plans/spec:
By others.
404.1
[FI6]1
75% of lamps in permanent
fixtures or 75% of permanent
fixtures have high efficacy lamps.
Does not apply to low-voltage
lighting.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Location on plans/spec:
By others.
404.1.1
[FI23]3
Fuel gas lighting systems have
no continuous pilot light.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
303.3
[FI18]3
Manufacturer manuals for
mechanical and water heating
systems have been provided.
Complies
Does Not
Not Observable
Not Applicable
Requirement will be met.
Additional Comments/Assumptions:
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive
Duplex\Engineering\951100MEP.rck
Page 5 of 6
09/03/14
Report date:
03/04/15
1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3)
Project Title:
Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive
Duplex\Engineering\951100MEP.rck
Page 6 of 6
09/03/14
Report date:
03/04/15