HomeMy WebLinkAboutcompliance-report-20140903_125501_626.pdfInspection Checklist Requirements: 100.0% were addressed directly in the REScheck software REScheck Software Version 4.5.0 Text in the "Comments/Assumptions" column is provided by the user in the REScheck Requirements screen. For each requirement, the user certifies that a code requirement will be met and how that is documented, or that an exception is being claimed. Where compliance is itemized in a separate table, a reference to that table is provided. Energy Code: 2012 IECC Section # & Req.ID Pre-Inspection/Plan Review Plans Verified Value Field Verified Value Complies? Comments/Assumptions 103.1, 103.2, 403.7 [PR3]1 Construction drawings and documentation demonstrate energy code compliance for lighting and mechanical systems. Systems serving multiple dwelling units must demonstrate compliance with the IECC Commercial Provisions. Complies Does Not Not Observable Not Applicable Requirement will be met. 302.1, 403.6 [PR2]2 Heating and cooling equipment is sized per ACCA Manual S based on loads calculated per ACCA Manual J or other methods approved by the code official. Heating: Btu/hr_____ Cooling: Btu/hr_____ Heating: Btu/hr_____ Cooling: Btu/hr_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive Duplex\Engineering\951100MEP.rck Page 2 of 6 09/03/14 Report date: 03/04/15 2012 IECC Foundation Inspection Complies? Comments/Assumptions 403.8 [FO12]2 Snow- and ice-melting system controls installed. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive Duplex\Engineering\951100MEP.rck Page 3 of 6 09/03/14 Report date: 03/04/15 Section # & Req.ID Framing / Rough-In Inspection Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.2.1 [FR12]1 Supply ducts in attics are insulated to ≥R-8. All other ducts in unconditioned spaces or outside the building envelope are insulated to ≥R-6. R-_____ R-_____ R-_____ R-_____ Complies Does Not Not Observable Not Applicable Exception: Ducts located completely inside the building envelope. 403.2.2 [FR13]1 All joints and seams of air ducts, air handlers, and filter boxes are sealed. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.2.3 [FR15]3 Building cavities are not used as ducts or plenums. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3 [FR17]2 HVAC piping conveying fluids above 105 ºF or chilled fluids below 55 ºF are insulated to ≥R- 3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable Requirement will be met. 403.3.1 [FR24]2 Protection of insulation on HVAC piping. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.4.2 [FR18]2 Hot water pipes are insulated to ≥R-3. R-_____ R-_____ Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive Duplex\Engineering\951100MEP.rck Page 4 of 6 09/03/14 Report date: 03/04/15 Section # & Req.ID Final Inspection Provisions Plans Verified Value Field Verified Value Complies? Comments/Assumptions 403.2.2 [FI4]1 Duct tightness test result of <=4 cfm/100 ft2 across the system or <=3 cfm/100 ft2 without air handler @ 25 Pa. For rough-in tests, verification may need to occur during Framing Inspection. _____ cfm/100 ft2 _____ cfm/100 ft2 Complies Does Not Not Observable Not Applicable Exception: All ducts and air handlers are located within conditioned space. 403.2.2.1 [FI24]1 Air handler leakage designated by manufacturer at <=2% of design air flow. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.1.1 [FI9]2 Programmable thermostats installed on forced air furnaces. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.1.2 [FI10]2 Heat pump thermostat installed on heat pumps. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. 403.4.1 [FI11]2 Circulating service hot water systems have automatic or accessible manual controls. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.5.1 [FI25]2 All mechanical ventilation system fans not part of tested and listed HVAC equipment meet efficacy and air flow limits. Complies Does Not Not Observable Not Applicable Requirement will be met. 403.9.1 [FI12]3 Readily accessible switch on heaters for swimming pools or permanent in-ground spas. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. Location on plans/spec: By others. 403.9.2 [FI19]3 Timer switches on heaters and pumps serving pools and permanent spas. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. Location on plans/spec: By others. 403.9.3 [FI20]3 Heated pools and permanent spas have a vapor retardant cover. Complies Does Not Not Observable Not Applicable Exception: Requirement is not applicable. Location on plans/spec: By others. 404.1 [FI6]1 75% of lamps in permanent fixtures or 75% of permanent fixtures have high efficacy lamps. Does not apply to low-voltage lighting. Complies Does Not Not Observable Not Applicable Requirement will be met. Location on plans/spec: By others. 404.1.1 [FI23]3 Fuel gas lighting systems have no continuous pilot light. Complies Does Not Not Observable Not Applicable Requirement will be met. 303.3 [FI18]3 Manufacturer manuals for mechanical and water heating systems have been provided. Complies Does Not Not Observable Not Applicable Requirement will be met. Additional Comments/Assumptions: 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive Duplex\Engineering\951100MEP.rck Page 5 of 6 09/03/14 Report date: 03/04/15 1 High Impact (Tier 1) 2 Medium Impact (Tier 2) 3 Low Impact (Tier 3) Project Title: Data filename: \\bgce-rsnas\Data\BGProjects\9511.00 182 West Meadow Drive Duplex\Engineering\951100MEP.rck Page 6 of 6 09/03/14 Report date: 03/04/15