HomeMy WebLinkAboutE000 COVER SHEET.pdf ' ABOVE SEA LEVEL PROJECT ALTITUDE 8100 '*' ISSUED FOR INFORMATION ONLY ' ' NOT PART OF SET ' ' ISSUED AS PART OF A SET ISSUE LOG KEY: # DATE ISSUE LOG ELECTRICAL SHEET INDEX TITLE ELECTRICAL COVER SHEET E0.00 P ER M IT SET 09.05.14 BASEMENT ELECTRICAL PLAN E2.00 MAIN FLOOR ELECTRICALPLAN E2.10 SECOND FLOOR ELECTRICAL PLAN E2.20 E3.00 ELECTRICAL DIAGRAMS GENERAL NOTES: GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED ISOLATED GROUND DUPLEX RECEPTACLE WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUNCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER C FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER ENCLOSED CIRCUIT BREAKER PULL BOX PUSH BUTTON TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR METER THERMOSTAT ATS AUTOMATIC TRANSFER SWITCH ONE-LINE DIAGRAM SYMBOLS CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN DISCONNECT SWITCH FUSE CIRCUIT BREAKER CURRENT TRANSFORMER POTENTIAL TRANSFORMER METER SURGE SUPPRESSION DEVICE VOLT-METER SELECTOR SWITCH GROUND GF GROUND FAULT PROTECTION AMP-METER ST SHUNT TRIP NORMALLY OPEN CONTACT NORMALLY CLOSED CONTACT COLD WATER GROUND CONNECTION BUILDING STEEL GROUND CONNECTION LIGHTING SYMBOLS RECESSED LIGHTING FIXTURE WALL MOUNTED LIGHT WALL MOUNTED UP-LIGHT PENDANT MOUNTED LIGHT SURFACE MOUNTED LIGHT DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE MONO-POINT LIGHTING FIXTURE RECESSED STEP LIGHT FLUORESCENT STRIP LIGHT WALL MOUNTED LINEAR FLUORESCENT LIGHT RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN EMERGENCY LIGHTS CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN TIMER SWITCH MULTI-OUTLET PLUG STRIP TIME CLOCK PHOTO-CELL SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH KEY SWITCH LV VARIABLE SPEED SWITCH DIMMER THREE-WAY DIMMER LOW VOLTAGE SWITCH WALL OCCUPANCY SENSOR/SWITCH THERMAL OVERLOAD SWITCH SMALL ROOM OCCUPANCY SENSOR LARGE ROOM OCCUPANCY SENSOR CORRIDOR OCCUPANCY SENSOR FIRE ALARM SYMBOLS FIRE ALARM CONTROL PANEL REMOTE ANNUNCIATOR PANEL SMOKE DETECTOR HEAT DETECTOR COMBO SMOKE/HEAT DETECTOR FIRE ALARM HORN FIRE ALARM STROBE FIRE ALARM COMBO HORN/STROBE FIRE ALARM PULL STATION F FIRE ALARM SPEAKER F FIRE ALARM COMBO SPEAKER/STROBE FIREMAN'S PHONE JACK DUCT SMOKE DETECTOR SPRINKLER SYSTEM FLOW SWITCH SPRINKLER SYSTEM TAMPER SWITCH INDICATES DEMOLITION. NOTE: LIGHT LINEWEIGHT INDICATES EXISTING. NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. FIRE/SMOKE DAMPER TELECOMMUNICATION SYMBOLS PHONE OUTLET DATA OUTLET COMBO PHONE/DATA OUTLET FLOOR MOUNTED TELEVISION OUTLET WALL MOUNTED TELEVISION OUTLET CLOCK OUTLET CEILING MOUNTED SPEAKER WALL MOUNTED SPEAKER VOLUME CONTROL FLOOR MOUNTED MICROPHONE OUTLET WALL MOUNTED MICROPHONE OUTLET INTERCOM STATION CHIME PHONE FLOOR OUTLET DATA FLOOR OUTLET COMBO PHONE/DATA FLOOR OUTLET ABBREVIATIONS AVC - ABOVE FINISHED CEILING AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AL - ALUMINUM BFG - BELOW FINISH GRADE C - CONDUIT CKT - CIRCUIT CT - CURRENT TRANSFORMER EM - EMERGENCY EWC - ELECTRIC WATER COOLER (E) - EXISTING FBO - FURNISHED BY OWNER GRD - GROUND GFI - GROUND FAULT CIRCUIT INTERRUPTER IG - ISOLATED GROUND IAW - IN ACCORDANCE WITH NIC - NOT IN CONTRACT DW - DISHWASHER DISP - GARBAGE DISPOSAL NL - NIGHT LIGHT NTS - NOT TO SCALE REF - REFRIGERATOR SPD - SURGE PROTECTIVE DEVICE UG - UNDERGROUND UNO - UNLESS NOTED OTHERWISE WP - WEATHER PROOF XP - EXPLOSION PROOF +18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOOR DAYLIGHT PHOTO SENSOR DL - - J J J PC TC TS T C T PB CB N S T S O D 3 D S V S K S J S 4 S 3 S OC OC OC CH IC M M V S TV TV FSD FT FF DD F F H SH HD SD ANN FACP A V SS M ELECTRICAL LEGEND POWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE NO SCALE TYPICAL DEVICE ALIGNMENT EQ EQ 6"MIN. ℄ ℄ ℄ DOOR WINDOW EQ EQ ℄ LIGHTING CONTROL ℄ ℄ OFFSET COMMUNICATIONS DEVICES FROM POWER DEVICES TO EITHER OPPOSITE SIDE OF STUD BAY, OR ADJACENT STUD BAY. 1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. EQ BACKSPLASH ABOVE COUNTER DEVICE RECEPTACLE COUNTERTOP EQ FINISHED FLOOR FINISHED CEILING 6" MIN. 20" MAX. ALIGN DEVICES (OUTLETS, CONTROLS, ETC.) VERTICALLY. DO VERTICALLY ALIGN POWER AND COMMUNICATIONS DEVICES SIMULTANEOUSLY. 18" 48"64" 78" 90" 78" 64" 90" 6"MIN FIRE ALARM DEVICES 48" ELECTRICAL DEVICES 96" 1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA DIMENSIONS SHALL GOVERN. 2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS. LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT. WALL-MOUNT NO SCALE TYPICAL DEVICE MOUNTING HEIGHTS OC D LV S CB C TS TC ANN FACP S H S H F 120" MAX. 80" MIN. 96" MAX. TOP OF DEVICE 9'-0"+ CEILING 8'-0" CEILING TOP OF CABINET TOP OF CABINET TOP OF DEVICE CL OF DEVICE TOP OF DEVICE TOP OF CABINET TOP OF CABINET BOTTOM OF DEVICE MINIMUM, TOP OF DEVICE FINISHED FLOOR FINISHED CEILING 1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF WORK. 2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS. 3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED OF SUCH WORK. 4. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID. 5. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT. 6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND ORDINANCES. 7. PROVIDE PERMITS AND INSPECTIONS REQUIRED. 8. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS. 9. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE), PULLBOXES, TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90 PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY DRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE ELECTRICAL UTILITY COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL, CONSTRUCTION SCHEDULING AND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OF ANY SCHEDULING CONFLICTS. 10. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN. 11. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION. 12. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS, AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE WITH EQUIPMENT ACTUALLY SUPPLIED. 13. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION. 14. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY. 15. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT. 16. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION, PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT, ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT. 17. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS. 18. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS. 19. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT. 20. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS SWEEPS (12 TIMES THE DIAMETER). 21. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE CORRECTIONS NECESSARY AT NO COST TO OWNER. 22. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE OWNER. 23. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES, MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE. 24. PROVIDE TAMPER RESISTANT RECEPTACLES IN ACCORDANCE WITH NEC 406.12. 25. PROVIDE ARC-FAULT PROTECTED CIRCUIT BREAKERS FOR ALL 120 VOLT CIRCUITS IN ACCORDANCE WITH NEC 210.12. 26. VERIFY ALL RECEPTACLE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. CONFIRM WITH ARCHITECT VIA BOX WALK AFTER ROUGH-IN. 11.10.14 9 0 % C D 'S 01.06.15 C O N S T R U C T IO N D O C U M EN T S E3.01 ELECTRICAL DIAGRAMS PER N.E.C. ARTICLE 680-70 AS AMENDED BY EAGLE COUNTY, 1-11-99 WHIRLPOOL TUB POWER SERVICE DIAGRAM NO SCALE RESETTABLE FACELESS GFCI AT 5'-0" AFF, HUBBEL #GF535OIA OR EQUIVALENT. WALL MOUNTED. 120V CKT 2/#12, #12 (INSULATED) GRD, 1/2"C. RECEPT FOR WHIRLPOOL TUB 15"x20" ACCESS PANEL IS REQUIRED. COORDINATE AND VERIFY WITH TUB SELECTION. CORD, MAX. 3'-0" LONG. PUMP OR BLOWER 5'-0" MIN 1. BASEMENTS OF BOTH UNITS WILL BE WHITE-BOX FINISH ONLY, WITH PROVISIONS FOR FUTURE BUILD-OUT. 2. BASEMENT LOAD PANELS ARE ANTICIPATED TO BE INSTALLED; CIRCUITS AND OUTLETS TO BE INSTALLED DURING BUILD-OUT. FULL INSTALLATION OF THE MECHANICAL ROOMS IS ANTICIPATED. BASEMENT BUILD-OUT: ELECTRICAL SPECIFICATIONS E0.10 B A S E M E N T A D DIT IO N S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100E000.dwg Printed By: cadd-drp February 06, 2015 - 10:26am LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET E0.00 ELECTRICAL COVER SHEET 04/15/15