HomeMy WebLinkAboutE000 COVER SHEET.pdf ' ABOVE SEA LEVEL
PROJECT ALTITUDE
8100
'*' ISSUED FOR INFORMATION ONLY
' ' NOT PART OF SET
' ' ISSUED AS PART OF A SET
ISSUE LOG KEY:
#
DATE
ISSUE LOG
ELECTRICAL SHEET INDEX
TITLE
ELECTRICAL COVER SHEET
E0.00
P ER M IT SET
09.05.14
BASEMENT ELECTRICAL PLAN
E2.00
MAIN FLOOR ELECTRICALPLAN
E2.10
SECOND FLOOR ELECTRICAL PLAN
E2.20
E3.00 ELECTRICAL DIAGRAMS
GENERAL NOTES:
GFCI DUPLEX RECEPTACLE
DUPLEX RECEPTACLE; HALF SWITCHED
ISOLATED GROUND DUPLEX RECEPTACLE
WALL MOUNTED SPECIAL OUTLET AS NOTED
SPECIAL OUTLET AS NOTED
JUNCTION BOX
WALL MOUNTED JUNCTION BOX
FLOOR MOUNTED JUNCTION BOX
DUPLEX RECEPTACLE MOUNTED ABOVE COUNTER
C
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE
FLUSH FLOOR MOUNTED DOUBLE DUPLEX RECEPTACLE
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE; HALF SWITCHED
FLUSH FLOOR MOUNTED DUPLEX RECEPTACLE AND TELECOM
DIVISION 15 EQUIPMENT POWER CONNECTION
FUSED DISCONNECT
NON FUSED DISCONNECT
MOTOR STARTER
ENCLOSED CIRCUIT BREAKER
PULL BOX
PUSH BUTTON
TRANSFORMER
PANELBOARD OR LOADCENTER
CONTACTOR
ELECTRIC MOTOR
METER
THERMOSTAT
ATS
AUTOMATIC TRANSFER SWITCH
ONE-LINE DIAGRAM SYMBOLS
CIRCUIT HOMERUN
CONDUIT RUN
CONDUIT RUN BELOW GRADE
CONDUIT UP
CONDUIT DOWN
DISCONNECT SWITCH
FUSE
CIRCUIT BREAKER
CURRENT TRANSFORMER
POTENTIAL TRANSFORMER
METER
SURGE SUPPRESSION DEVICE
VOLT-METER
SELECTOR SWITCH
GROUND
GF
GROUND FAULT PROTECTION
AMP-METER
ST
SHUNT TRIP
NORMALLY OPEN CONTACT
NORMALLY CLOSED CONTACT
COLD WATER GROUND CONNECTION
BUILDING STEEL GROUND CONNECTION
LIGHTING SYMBOLS
RECESSED LIGHTING FIXTURE
WALL MOUNTED LIGHT
WALL MOUNTED UP-LIGHT
PENDANT MOUNTED LIGHT
SURFACE MOUNTED LIGHT
DIRECTIONAL/ADJUSTABLE RECESSED LIGHTING FIXTURE
MONO-POINT LIGHTING FIXTURE
RECESSED STEP LIGHT
FLUORESCENT STRIP LIGHT
WALL MOUNTED LINEAR FLUORESCENT LIGHT
RECESSED OR SURFACE MOUNTED FLUORESCENT TROFFER
FIXTURE WITH EMERGENCY BACKUP OR ON EM CIRCUIT
WALL MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN
EMERGENCY LIGHTS
CEILING MOUNTED EXIT SIGN W/ FACES & ARROWS AS SHOWN
TIMER SWITCH
MULTI-OUTLET PLUG STRIP
TIME CLOCK
PHOTO-CELL
SWITCH
THREE-WAY SWITCH
FOUR-WAY SWITCH
DOOR JAMB SWITCH
KEY SWITCH
LV
VARIABLE SPEED SWITCH
DIMMER
THREE-WAY DIMMER
LOW VOLTAGE SWITCH
WALL OCCUPANCY SENSOR/SWITCH
THERMAL OVERLOAD SWITCH
SMALL ROOM OCCUPANCY SENSOR
LARGE ROOM OCCUPANCY SENSOR
CORRIDOR OCCUPANCY SENSOR
FIRE ALARM SYMBOLS
FIRE ALARM CONTROL PANEL
REMOTE ANNUNCIATOR PANEL
SMOKE DETECTOR
HEAT DETECTOR
COMBO SMOKE/HEAT DETECTOR
FIRE ALARM HORN
FIRE ALARM STROBE
FIRE ALARM COMBO HORN/STROBE
FIRE ALARM PULL STATION
F
FIRE ALARM SPEAKER
F
FIRE ALARM COMBO SPEAKER/STROBE
FIREMAN'S PHONE JACK
DUCT SMOKE DETECTOR
SPRINKLER SYSTEM FLOW SWITCH
SPRINKLER SYSTEM TAMPER SWITCH
INDICATES DEMOLITION.
NOTE: LIGHT LINEWEIGHT INDICATES EXISTING.
NOTE: ALL SYMBOLS SHOWN ON LEGEND
ARE NOT NECESSARILY USED.
FIRE/SMOKE DAMPER
TELECOMMUNICATION SYMBOLS
PHONE OUTLET
DATA OUTLET
COMBO PHONE/DATA OUTLET
FLOOR MOUNTED TELEVISION OUTLET
WALL MOUNTED TELEVISION OUTLET
CLOCK OUTLET
CEILING MOUNTED SPEAKER
WALL MOUNTED SPEAKER
VOLUME CONTROL
FLOOR MOUNTED MICROPHONE OUTLET
WALL MOUNTED MICROPHONE OUTLET
INTERCOM STATION
CHIME
PHONE FLOOR OUTLET
DATA FLOOR OUTLET
COMBO PHONE/DATA FLOOR OUTLET
ABBREVIATIONS
AVC - ABOVE FINISHED CEILING
AFF - ABOVE FINISHED FLOOR
AFG - ABOVE FINISHED GRADE
AL - ALUMINUM
BFG - BELOW FINISH GRADE
C - CONDUIT
CKT - CIRCUIT
CT - CURRENT TRANSFORMER
EM - EMERGENCY
EWC - ELECTRIC WATER COOLER
(E) - EXISTING
FBO - FURNISHED BY OWNER
GRD - GROUND
GFI - GROUND FAULT CIRCUIT INTERRUPTER
IG - ISOLATED GROUND
IAW - IN ACCORDANCE WITH
NIC - NOT IN CONTRACT
DW - DISHWASHER
DISP - GARBAGE DISPOSAL
NL - NIGHT LIGHT
NTS - NOT TO SCALE
REF - REFRIGERATOR
SPD - SURGE PROTECTIVE DEVICE
UG - UNDERGROUND
UNO - UNLESS NOTED OTHERWISE
WP - WEATHER PROOF
XP - EXPLOSION PROOF
+18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOOR
DAYLIGHT PHOTO SENSOR
DL
-
-
J
J
J
PC
TC
TS
T
C
T
PB
CB
N
S
T
S
O
D
3
D
S
V
S K
S
J
S 4
S
3
S
OC
OC
OC
CH
IC
M
M
V
S
TV
TV
FSD
FT
FF
DD
F
F
H
SH
HD
SD
ANN
FACP
A
V
SS
M
ELECTRICAL LEGEND
POWER SYMBOLS
SINGLE RECEPTACLE
DUPLEX RECEPTACLE
DOUBLE DUPLEX RECEPTACLE
NO SCALE
TYPICAL DEVICE ALIGNMENT
EQ EQ
6"MIN.
℄
℄
℄
DOOR WINDOW
EQ EQ
℄ LIGHTING
CONTROL
℄
℄
OFFSET COMMUNICATIONS
DEVICES FROM POWER
DEVICES TO EITHER
OPPOSITE SIDE OF STUD BAY,
OR ADJACENT STUD BAY.
1. IF ALIGNMENT OF DEVICES INDICATED HERE IS IN CONFLICT
WITH ADA REQUIREMENTS DUE TO INSTALLATION DETAIL, ADA
DIMENSIONS SHALL GOVERN.
2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS.
LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL
SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS
SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE COMPLIANT.
EQ
BACKSPLASH
ABOVE
COUNTER
DEVICE
RECEPTACLE
COUNTERTOP
EQ
FINISHED FLOOR
FINISHED CEILING
6"
MIN.
20"
MAX.
ALIGN DEVICES (OUTLETS,
CONTROLS, ETC.)
VERTICALLY. DO
VERTICALLY ALIGN POWER
AND COMMUNICATIONS
DEVICES SIMULTANEOUSLY.
18"
48"64"
78"
90"
78"
64"
90"
6"MIN
FIRE ALARM DEVICES
48"
ELECTRICAL DEVICES
96"
1. IF MOUNTING HEIGHT OF DEVICES INDICATED HERE IS IN
CONFLICT WITH ADA REQUIREMENTS DUE TO INSTALLATION
DETAIL, ADA DIMENSIONS SHALL GOVERN.
2. REFERENCE ARCHITECTURAL INTERIOR ELEVATIONS.
LOCATIONS SHOWN ON INTERIOR ELEVATIONS SHALL
SUPERCEDE LOCATIONS SHOWN HERE, UNLESS LOCATIONS
SHOWN ON INTERIOR ELEVATIONS ARE NOT CODE
COMPLIANT.
WALL-MOUNT
NO SCALE
TYPICAL DEVICE MOUNTING HEIGHTS
OC
D LV S
CB
C
TS
TC
ANN
FACP
S
H
S
H
F
120"
MAX.
80"
MIN.
96"
MAX.
TOP OF DEVICE
9'-0"+ CEILING
8'-0" CEILING
TOP OF CABINET
TOP OF CABINET
TOP OF DEVICE
CL OF DEVICE
TOP OF DEVICE
TOP OF CABINET
TOP OF CABINET
BOTTOM OF DEVICE
MINIMUM, TOP OF DEVICE
FINISHED FLOOR
FINISHED CEILING
1. DO NOT SCALE DRAWINGS. VERIFY DIMENSIONS ON ARCHITECTURAL DRAWINGS AND IN FIELD PRIOR TO COMMENCEMENT OF
WORK.
2. VISIT SITE PRIOR TO BID AND VERIFY THAT CONDITIONS ARE AS INDICATED. CONTRACTOR SHALL INCLUDE IN HIS BID COSTS
REQUIRED TO MAKE HIS WORK MEET EXISTING CONDITIONS.
3. SYSTEM OUTAGES SHALL BE PERMITTED ONLY AT TIMES APPROVED BY OWNER - IN WRITING. WORK WHICH COULD RESULT IN AN
ACCIDENTAL OUTAGE (BEYOND BRANCH CIRCUITS) SHALL BE PERFORMED WITH THE OWNER'S MAINTENANCE PERSONNEL ADVISED
OF SUCH WORK.
4. REVIEW ARCHITECTURAL, MECHANICAL AND OTHER DRAWINGS PRIOR TO BID.
5. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE ARCHITECT.
6. WORK, MATERIALS, AND EQUIPMENT SHALL CONFORM TO THE LATEST EDITIONS OF LOCAL, STATE, AND NATIONAL CODES AND
ORDINANCES.
7. PROVIDE PERMITS AND INSPECTIONS REQUIRED.
8. CONTRACTOR'S FAILURE TO ORDER OR RELEASE ORDER FOR MATERIALS AND/OR EQUIPMENT WILL NOT BE ACCEPTED AS A
REASON TO SUBSTITUTE ALTERNATE MATERIALS, EQUIPMENT, OR INSTALLATION METHODS.
9. VERIFY EXACT LOCATIONS OF EXISTING AND NEW UNDERGROUND UTILITIES, PIPING AND RACEWAY SYSTEMS PRIOR TO
TRENCHING. PROVIDE NECESSARY TRENCHING, BACKFILL, EXCAVATION, SUPPORTS, SERVICE FEEDERS (CONDUIT AND/OR WIRE),
PULLBOXES, TRANSFORMER PADS, SAWCUTTING AND PATCHING, CONCRETE/PAVING, ETC. REQUIRED. BACKFILL TRENCHES TO 90
PERCENT COMPACTION AND PATCH TO MATCH EXISTING. CONTRACTOR SHALL OBTAIN AND VERIFY EXACT UTILITY COMPANY
DRAWINGS AND REQUIREMENTS. ELECTRICAL CONTRACTOR IS TO SUBMIT A COMPLETE CONSTRUCTION DRAWING SET TO THE
ELECTRICAL UTILITY COMPANY WITH-IN 10 DAYS OF AWARD OF CONTRACT. COORDINATE TIMELINE OF THEIR REVIEW, APPROVAL,
CONSTRUCTION SCHEDULING AND INSTALLATION OF THE UTILITY TRANSFORMER WITH THE UTILITY COMPANY. NOTIFY OWNER OF
ANY SCHEDULING CONFLICTS.
10. VERIFY EXACT LOCATION OF EQUIPMENT TO BE FURNISHED BY OTHERS PRIOR TO ROUGH-IN.
11. INSTALL ALL MATERIALS IN ACCORDANCE WITH THE MANUFACTURER'S RECOMMENDATIONS. ANY DEVIATIONS SHALL BE BROUGHT
TO THE ARCHITECT/ENGINEER'S ATTENTION PRIOR TO INSTALLATION.
12. FINAL CONNECTIONS TO EQUIPMENT SHALL BE IN ACCORDANCE WITH MANUFACTURER'S APPROVED WIRING DIAGRAMS, DETAILS,
AND INSTRUCTIONS. IT SHALL BE THE CONTRACTOR'S RESPONSIBILITY TO PROVIDE MATERIALS AND EQUIPMENT COMPATIBLE
WITH EQUIPMENT ACTUALLY SUPPLIED.
13. CONTRACTOR SHALL BE RESPONSIBLE FOR REPLACING EQUIPMENT WHICH IS DAMAGED DUE TO INCORRECT FIELD WIRING
PROVIDED UNDER THIS SECTION, OR FACTORY WIRING IN EQUIPMENT PROVIDED UNDER THIS SECTION.
14. ALL ELECTRICAL SYSTEMS COMPONENTS SHALL BE LISTED OR LABELED BY U.L. OR OTHER RECOGNIZED TESTING FACILITY.
15. WIRING DEVICES SHALL BE SPECIFICATION GRADE AND RATED AT 20 AMPERES FOR LIGHT SWITCHES, AND 20 AMPERES FOR
DUPLEX RECEPTACLES. THE COLOR OF THE DEVICES AND COVER PLATES SHALL BE AS DIRECTED BY ARCHITECT.
16. ALL EMPTY RACEWAY SYSTEMS SHALL HAVE A 200LB NYLON PULL STRING OR EQUAL, AND SHALL BE IDENTIFIED AT ALL JUNCTION,
PULL AND TERMINATION POINTS, USING PERMANENT METALLIC TAGS. TAG SHALL INDICATE INTENDED USE OF CONDUIT,
ORIGINATION, AND TERMINATION POINTS OF EACH INDIVIDUAL CONDUIT.
17. WIRE SHALL BE COPPER, 75 DEGREE CELSIUS RATED FOR GENERAL USE. WIRING WITHIN 3 INCHES OF FLUORESCENT BALLASTS
WIRE SHALL BE COPPER, MINIMUM 90 DEGREE CELSIUS RATED. SIZES INDICATED ARE FOR INSTALLATION IN A MAXIMUM 30 DEGREE
CELSIUS AMBIENT. CONDUCTOR AMPACITY SHALL BE DERATED FOR HIGHER AMBIENT INSTALLATIONS.
18. PANEL DIRECTORIES SHALL BE REMOVABLE. ROOM NAMES AND NUMBERS SHALL BE AS DIRECTED BY OWNER. DIRECTORIES
SHALL BE TYPED AND INSTALLED UNDER CLEAR PLASTIC COVERS.
19. FINAL CONNECTIONS TO MOTORS, TRANSFORMERS, AND OTHER VIBRATING EQUIPMENT SHALL BE SEAL TITE FLEX AND APPROVED
FITTINGS. DO NOT SECURE CONDUITS, DISCONNECTS, OR DEVICES TO DUCTWORK OR MECHANICAL EQUIPMENT.
20. FIRE ALARM, SOUND, TELEPHONE, COMPUTER AND SIMILAR SYSTEMS CONDUITS LARGER THAN 1” SHALL HAVE LONG RADIUS
SWEEPS (12 TIMES THE DIAMETER).
21. SYSTEMS SHALL BE TESTED FOR PROPER OPERATION. IF TESTS SHOW THAT WORK IS DEFECTIVE, CONTRACTOR SHALL MAKE
CORRECTIONS NECESSARY AT NO COST TO OWNER.
22. GUARANTEE THE INSTALLATION AGAINST DEFECTS IN MATERIALS AND WORKMANSHIP WHICH MAY OCCUR UNDER NORMAL USAGE
FOR A PERIOD OF ONE YEAR AFTER OWNER'S ACCEPTANCE. DEFECTS SHALL BE PROMPTLY REMEDIED WITHOUT COST TO THE
OWNER.
23. SYSTEMS SHALL BE COMPLETE, OPERABLE, AND READY FOR CONTINUOUS OPERATION. LIGHTS, SWITCHES, RECEPTACLES,
MOTORS, ETC. SHALL BE CONNECTED AND OPERABLE.
24. PROVIDE TAMPER RESISTANT RECEPTACLES IN ACCORDANCE WITH NEC 406.12.
25. PROVIDE ARC-FAULT PROTECTED CIRCUIT BREAKERS FOR ALL 120 VOLT CIRCUITS IN ACCORDANCE WITH NEC 210.12.
26. VERIFY ALL RECEPTACLE LOCATIONS WITH ARCHITECTURAL ELEVATIONS. CONFIRM WITH ARCHITECT VIA BOX WALK AFTER
ROUGH-IN.
11.10.14
9 0 % C D 'S
01.06.15
C O N S T R U C T IO N D O C U M EN T S
E3.01 ELECTRICAL DIAGRAMS
PER N.E.C. ARTICLE 680-70 AS AMENDED BY EAGLE COUNTY, 1-11-99
WHIRLPOOL TUB POWER SERVICE DIAGRAM
NO SCALE
RESETTABLE FACELESS GFCI AT
5'-0" AFF, HUBBEL #GF535OIA OR
EQUIVALENT. WALL MOUNTED.
120V CKT
2/#12, #12 (INSULATED) GRD, 1/2"C.
RECEPT FOR WHIRLPOOL TUB
15"x20" ACCESS PANEL IS
REQUIRED. COORDINATE AND
VERIFY WITH TUB SELECTION.
CORD, MAX. 3'-0" LONG.
PUMP OR BLOWER
5'-0" MIN
1. BASEMENTS OF BOTH UNITS WILL BE WHITE-BOX
FINISH ONLY, WITH PROVISIONS FOR FUTURE
BUILD-OUT.
2. BASEMENT LOAD PANELS ARE ANTICIPATED TO BE
INSTALLED; CIRCUITS AND OUTLETS TO BE
INSTALLED DURING BUILD-OUT. FULL INSTALLATION
OF THE MECHANICAL ROOMS IS ANTICIPATED.
BASEMENT BUILD-OUT:
ELECTRICAL SPECIFICATIONS
E0.10
B A S E M E N T A D DIT IO N
S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100E000.dwg Printed By: cadd-drp February 06, 2015 - 10:26am LC-XXX
COPYRIGHT 2014
B
ANZE
G
EAUDIN
(970) 949-6108
(303) 278-3820
(970) 221-5691
(505) 323-9070
(307) 739-3944
Vail:
Denver:
Fort Collins:
Albuquerque:
Jackson:
www.bgce.com
MERIBEL CORP. RESIDENCE
Project Number - 1428
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
11/10/14
90% CD SET
09/05/14
PERMIT SET
7/30/14
DESIGN REVIEW
01/06/15
CD SET
E0.00
ELECTRICAL
COVER
SHEET
04/15/15