HomeMy WebLinkAboutM000 COVER SHEET.pdf ' ABOVE SEA LEVEL
PROJECT ALTITUDE
8,100
'*' ISSUED FOR INFORMATION ONLY
' ' NOT PART OF SET
' ' ISSUED AS PART OF A SET
ISSUE LOG KEY:
#
DATE
ISSUE LOG
MECHANICAL SHEET INDEX
TITLE
MECHANICAL COVER SHEET
M0.00
P ERMIT SET
09.05.14
MECHANICAL SCHEDULES
M0.10
MECHANICAL SCHEDULES
M0.20
MECHANICAL SITE PLAN
M1.10
BASEMENT PIPING PLAN
M2.00
MAIN FLOOR PIPING PLAN
M2.10
SECOND FLOOR PIPING PLAN
M2.20
M3.00
M3.10
M3.20
MECHANICAL DIAGRAMS
M4.00
BASEMENT MECHANICAL PLAN
MAIN FLOOR MECHANICAL PLAN
SECOND FLOOR MECHANICAL PLAN
MECHANICAL SPECIFICATIONS
M0.30
MECHANICAL CONTROLS
M5.00
FIXTURE CONNECTION SCHEDULE
WC WATER CLOSET (FLUSH VALVE)
ABBREV.
-
HW
1"
CW
4"
WASTE
2"
VENT
:
1. SIZES SHOWN ARE MINIMUM PIPE SIZES TO A SINGLE FIXTURE. LARGER SIZES MAY BE
INDICATED ON PLANS WHERE REQUIRED.
2. MINIMUM DOMESTIC PIPE SIZE TO 2 OR MORE FIXTURES IS 3/4".
3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS FOR INDIRECT WASTE SIZES.
4. WASTE AND VENT SIZES SHOWN ABOVE APPLY TO INDIVIDUAL VENTING ONLY. WHERE
ALLOWED, INDIVIDUAL VENT CONNECTIONS MAY BE OMITTED OR SIZES MAY VARY
WHEN CIRCUIT VENTS, COMMON VENTS, WASTE STACK VENTS, WET VENTS, OR
COMBINATION DRAIN AND VENT SYSTEMS ARE USED. PRIOR APPROVAL FROM THE
ENGINEER IS REQUIRED TO USE THESE ALTERNATIVE VENTING METHODS.
5. PROVIDE TRAP PRIMER FOR ALL FLOOR DRAINS AND FLOOR SINKS NOT LOCATED IN
FOOD SERVICE AREAS.
6. MINIMUM SIZE FOR WASTE AND VENT PIPING BENEATH SLAB IS 2".
7. ALL FIXTURES LISTED ARE NOT NECESSARILY USED ON THIS PROJECT.
8. REFER TO APPLIANCE SCHEDULES (BY OTHERS) FOR ADDITIONAL PLUMBING FIXTURE
CONNECTIONS SUCH AS INST-HOTS, COFFEE MAKERS, AND GARBAGE DISPOSALS.
9. PROVIDE ICE MAKER BOX ROUGH IN W/ 1/2"CW CONNECTION FOR ALL REFRIGERATOR
LOCATIONS.
WATER CLOSET (FLUSH TANK)
LAVATORY
HAND SINK
SERVICE SINK
MOP SERVICE BASIN
DRINKING FOUNTAIN / E.W.C.
KITCHEN SINK W/ OR W/O DISPOSER
BATHTUB / SHOWER
CLOTHES WASHER ROUGH-IN
DISHWASHER ROUGH-IN
BAR SINK
FLOOR SINK
FLOOR DRAIN
WORK SINK
HOSE BIB
WCT - 1/2" 4" 2"
LAV 1/2" 1-1/2" 1-1/2"
HS 1-1/2" 1-1/2"
SS 3" 2"
MSB 3/4" 3" 2"
DF - 1/2"
KS 1/2" 1/2" 2"
SH 3/4" 3/4" 2"
CW 1/2" 1/2" 2"
DW
BS
FS
FD
WS
HB
1/2"
1/2"
1/2"
3/4"
1/2"
1/2"
1-1/2" 1-1/2"
1-1/2"
1-1/2"
1-1/2"
-1/2"
1/2" 1/2"
2" 1-1/2"
1-1/2"
1-1/2"
-
-
-
-
---
3/4"
3/4"
3/4"
3"
2"
2"
2"
1-1/2"
1-1/2"
PRESSURE REDUCING VALVE
FLOW SWITCH
SHOCK ABSORBER
HOSE BIBB
STRAINER W/ BLOW-OFF VALVE
ROOF DRAIN
SAFETY RELIEF VALVE
FLOOR DRAIN
FLOOR SINK
HORIZONTAL CLEANOUT
VACUUM BREAKER
VERTICAL CLEANOUT
PRESSURE GAUGE W/ PIG TAIL & COCK
THERMOMETER
PRESSURE - TEMP. TAP
AIR VENT
PIPE ANCHOR
FLEXIBLE CONNECTOR
PIPE EXPANSION JOINT
PIPE UNION
DOUBLE CHECK BACKFLOW PREVENTER
PUMP & EQUIPMENT CONNECTOR
WALL HYDRANT
TEMPERATURE CONTROL VALVE (2-WAY)
DRAIN VALVE W/ HOSE END
PLUG VALVE IN RISER
FLOW BALANCING VALVE
GATE OR GLOBE VALVE IN RISER
FLOW CONTROL VALVE
BALL VALVE
PLUG OR BALANCING VALVE
CHECK VALVE
GLOBE VALVE
BUTTERFLY VALVE
VENTURI/FLOW INDICATOR
TEMPERATURE CONTROL VALVE (3-WAY)
SOLENOID VALVE
TEMPERATURE CONTROLLER OR SENSOR
90° ELBOW UP
TEE UP
TEE DOWN
DECK/ROOF DRAIN ABOVE
SHUT OFF (BALL, GATE, BUTTERFLY)
PIPING SYMBOLS
90° ELBOW DN
H B
W H
FS
S
TC
PLAN SYMBOLS
CONTROL PANEL/RADIANT MANIFOLD
T
-
-
-
-
P
-
--
S
H
CO
P
EPO
CO2
SP
CARBON DIOXIDE SENSOR
CARBON MONOXIDE SENSOR
FIRE RISER
DIAGRAM CONTINUATION REFERENCE
PLUMBING RISER
HEATING WATER RISER
THERMOSTAT
HVAC RISER
POINT OF NEW CONNECTION
DUCT STATIC PRESSURE SENSOR
ROOM PRESSURE SENSOR
HUMIDISTAT
REMOTE TEMPERATURE SENSOR
EMERGENCY POWER OFF SWITCH
ACCESS PANEL
SNOWMELT MANIFOLD
SECTION CUT LETTER/SHEET SHOWN ON
POINT OF DISCONNECTION
TYPE OF AIR DEVICE RE:
GRD SCHEDULE.
AIR DEVICE DESIGNATION KEY
# = AIR QUANTITY (CFM)
CA = COMB. AIR
OSA = OUTSIDE AIR
RET = RETURN
EXH = EXHAUST
XFR = TRANSFER
SIZE (INCHES) OR MINIMUM
FREE AREA REQUIRED IN
SQUARE FEET
A
150
12x6
NOTE: FOR STANDARD MODULE SIZE
REGISTERS, SIZE GIVEN IS NECK
SIZE. REFER TO GRD SCHEDULE
FOR MODULE SIZE.
B
XFR
12x6
INDICATES AIR INLET DEVICE
REFERENCE SAMPLE
FFI = FOR FURTHER INFORMATION
FCT = FOR CONTINUATION
SHEET NUMBER
DRAWING NUMBER OR DIAGRAM
LETTER
REFER TO:
RE: B/M400 FFI
NOTES
1. ALL SYMBOLS, ABBREVIATIONS, AND DESIGNATIONS
ON LEGEND SHEET ARE NOT NECESSARILY USED ON
THIS PROJECT.
2. THIS DRAWING SET CONSISTS OF DATA GENERATED, IN
PART, BY OTHER PARTIES. NOT ALL SYMBOLOGIES
AND NOTATION CONVENTIONS OCCURRING IN THIS
DRAWING SET ARE NECESSARILY DEFINED ON THESE
LEGENDS. CONSULT THE ENGINEER IN THE EVENT
SYMBOLOGY OR NOTATION INTERPRETATION IS
REQUIRED.
PIPING DESIGNATIONS
SNOWMELT SUPPLY
SNOWMELT RETURN
HEATING WATER SUPPLY (HIGH TEMP)
HEATING WATER RETURN (HIGH TEMP)
CHILLED WATER SUPPLY
CHILLED WATER RETURN
NATURAL GAS
MEDIUM PRESSURE GAS
REFRIGERANT SUCTION
REFRIGERANT LIQUID
DOMESTIC WATER (CW / DW)
DOMESTIC HOT WATER (HW / DHW)
DOMESTIC HOT WATER (TEMP. SHOWN)
DHW RECIRCULATION (HWC / DHR)
FIRE LINE
PRESSURIZED WASTE
PLUMBING VENT PIPE
WASTE PIPE
STORM DRAIN PIPE
STORM DRAIN OVERFLOW
LIQUID PROPANE GAS
SECONDARY DRAIN
SAND AND OIL WASTE
PROPANE GAS
HEATING WATER SUPPLY (LOW TEMP)
HEATING WATER RETURN (LOW TEMP)
SOLAR HEATING WATER SUPPLY
SOLAR HEATING WATER RETURN
HEATING WATER SUPPLY
HEATING WATER RETURN
DRAIN PIPE
GLYCOL FEED
HEATING WATER RETURN (HEAT PUMP)
HEATING WATER RETURN (HEAT PUMP)
PROPANE DRAIN
HYDRONIC PIPING
HWS(HT)
HWR(HT)
HWS(LT)
HWR(LT)
HWS
HWR
GF
HWS(HP)
HWR(HP)
CHS
CHR
SMR
SMS
SHWS
SHWR
PLUMBING PIPING
G
MG
LPG
PG
D
PD
NS
140°
RL
RS
NON-SOFTENED DOMESTIC WATER
PW
W
V
ST
SD
SO
ST(OF)
F
DUCTWORK LEGEND
SINGLE LINE DOUBLE LINE DESCRIPTION
90° ELBOW DOWN (ROUND DUCT ONLY)
ROUND 90° ELBOW UP (ROUND DUCT ONLY)
ROUND RADIUS ELBOW
90° STRAIGHT TEE
90° CONICAL TEE
45° BRANCH
45° CONICAL TEE
SIZE OR SHAPE TRANSITION
ROUND FLEXIBLE DUCT
90° ELBOW DN (NEGATIVE PRESSURE)
90° ELBOW DN (POSITIVE PRESSURE)
90° ELBOW UP (NEGATIVE PRESSURE)
90° ELBOW UP (POSITIVE PRESSURE)
90° RADIUS ELBOW
90° RADIUS ELBOW W/TURNING VANES
SQUARE DUCT SPLIT
ROUND DUCT SPLIT
COMBINATION FIRE AND SMOKE DAMPER
FIRE DAMPER
SMOKE DAMPER
MOTOR OPERATED DAMPER (MOD)
BACKDRAFT DAMPER
SMOKE DETECTOR
OFFSET TO CHANGE ELEVATION
(AT 30° WHEN POSSIBLE)
D = DROP R = RISE
D
F/S
BDD
SD
24x36
D
SPLIT BRANCH TAKE-OFF WITH SQUARE
ELBOW & SPLITTER DAMPER
SPLIT BRANCH TAKE-OFF WITH RADIUS
ELBOW & SPLITTER DAMPER
POSITIVE PRESSURE RISER, TYPICALLY
SUPPLY.
NEGATIVE PRESSURE RISER, TYPICALLY
RETURN, EXHAUST OR OUTSIDE AIR.
MAN VOLUME DAMPER, SINGLE BLADE
DAMPER(SBD) FOR ROUND OR <10" TALL,
OPPOSED BLADE DAMPER(OBD) >10" TALL.
DUCT SIZE: FIRST NUMBER IS PLAN WIDTH,
SECOND NUMBER IS DEPTH.
24x36
SD
F/S
BDD
PLAN ABBREVIATIONS
ABOVE FINISHED FLOOR
AIR ADMITTANCE VALVE
ABOVE FINISHED GRADE
AUTOMATIC
BUILDING CONTROL SYSTEM
BACK DRAFT DAMPER
BUILDING
AAV
AFF
AFG
AUTO
BCS
BDD
BLDG
BOTTOM OF PIPE FROM FINISHED FLOOR
BETWEEN
COMMON
COMBUSTION AIR
CONTROLS CONTRACTOR
CONTINUATION DESIGN BUILD
BOP
B/N
C
CA
CC
CDBBC
CUBIC FEET PER MINUTE (AIR FLOW RATE)
CAST IN PLACE
CEILING (OR COOLING)
CONCRETE
CONDENSATE
CONNECT
CONTRACTOR
CFM
CIP
CLG
CONC
COND
CONN
CONTR'R
CLEANOUT
CO
CLEANOUT TO GRADE
COTG
DOMESTIC HOT WATER RECIRC
EXISTING
DWR
(E)
EXHAUST AIR
EA
ENTERING AIR TEMPERATURE
ELECTRICAL CONTRACTOR
ENTERING WATER TEMPERATURE
EAT
EC
EXH EXHAUST
EWT
GENERAL CONTRACTOR
GROUND HEAT EXCHANGER
GC
GHX
GALLONS PER MINUTE (WATER FLOW RATE)
GPM
HORSEPOWER
HOT WATER
IN LIEU OF
HP
HW
ILO
KILOWATTS
KW
LEAVING AIR TEMPERATURE
LINEAR FOOT
LEAVING WATER TEMPERATURE
LAT
LF
LWT
MECHANICAL CONTRACTOR
MC
MANUFACTURER
MOTOR OPERATED DAMPER
NEW
MFG
MOD
(N)
NORMALLY CLOSED
NC
NATIONAL ELECTRIC CODE
NOT IN CONTRACT
NORMALLY OPEN
NEC
NIC
N0
OUTSIDE AIR
OA
OPPOSED BLADE VOLUME DAMPER
ON CENTER
OBD
OC
OUTSIDE AIR
OSA
RETURN AIR
REQUIRED
RA
REQ'D
REQUIREMENTS
REQ'MTS
SUPPLY AIR
SQUARE FOOT (FEET)
SA
SF
STATIC PRESSURE
SP
STAINLESS STEEL
THROW-AWAY
TYPICAL
SS
T.A.
TYP
UNLESS NOTED OTHERWISE
UNO
VENT THRU ROOF
VTR
WALL CLEANOUT
WCO
WITH REGARD TO
WATER COOLED
TRANSFER
WRT
W/C
XFR
DIAMETER
Ø
BY CONTRACTOR
COLD WATER
CW
HOT WATER RECIRC
HWC
ABOVE
ABV
BELOW FINISHED GRADE
BFG
DOMESTIC WATER
DOMESTIC HOT WATER
DW
DHW
DOWN
DN
DOMESTIC HOT WATER RECIRC
DHR
COMBINATION FIRE/SMOKE DAMPER
FURNISHED BY OWNER
FSD
FBO
FLOOR CLEANOUT
FCO
FOR CONTINUATION
FCT
FD FIRE DAMPER
REFER TO:
RE:
WITH
W/
EQUIPMENT ABBREVIATIONS
AIR HANDLING UNIT
AHU
AIR SEPARATOR
AS
BOILER (HOT WATER)
B
BASE BOARD
BB
BUFFER TANK
BT
CONSTANT VOLUME BOX
CV
DISHWASHER EXHAUST FAN
DEF
ELECTRIC BASEBOARD HEATER
EBH
FURNACE
F
FAN COIL
FC
FAN POWERED BOX
FP
GLYCOL FEEDER
GF
HUMIDIFIER
HC HEATING COIL
HP HEAT PUMP
HX HEAT EXCHANGER
KITCHEN EXHAUST FAN
KEF
MAKE-UP AIR UNIT
MAU
MOTOR CONTROL CENTER
MCC
MIXING VALVE
MV
PUMP (SEE PIPING LEGEND FOR DETAILS)
P
RETURN (OR RELIEF) AIR FAN
RF
RADIANT ZONE
RZ
SNOWMELT AREA
SA
SUMP BASIN
SB
SUPPLY FAN
SF
STORAGE TANK
ST
THERMOSTATIC MIXING VALVE
TMV
UNIT HEATER
UH
VARIABLE VOLUME BOX
VV
WATER HEATER
WH
H
CHILLER
CH
COILING COIL
CC
CIRC PUMP
CP
CABINET UNIT HEATER
CUH
COOLING TOWER
CT
DUCT COIL
DC
ELECTRIC WATER HEATER
EWH
EVAPORATIVE COOLING UNIT
ECU
ENERGY RECOVERY UNIT
ERU
EXHAUST FAN
EF
EXPANSION TANK
ET
VARIABLE VOLUME BOX W/ REHEAT
VR
MECHANICAL DIAGRAMS
M4.01
MECHANICAL CONTROLS
M5.01
MECHANICAL CONTROLS
M5.02
1. FIRE PROTECTION ELEMENTS SHOWN HEREIN FOR
COORDINATION PURPOSES ONLY. THE ENGINEERING
SEAL AFFIXED TO ANY PART OF THIS DOCUMENT SET
AND ANY RESPONSIBILITY OF ENGINEER OF RECORD
EXPRESSLY EXCLUDES ANY AND ALL FIRE
PROTECTION ELEMENTS SHOWN HEREIN.
2. THE FIRE PROTECTION CONTRACTOR WHO IS THE
WINNING BIDDER SHALL RETAIN THE SERVICES OF A
REGISTERED PROFESSIONAL FIRE PROTECTION
ENGINEER. SAID FIRE PROTECTION ENGINEER SHALL
PERFORM ALL DESIGN CALCULATIONS, PROVIDE A
COMPLETELY DESIGNED FIRE PROTECTION SYSTEM
IN A SEPARATE DOCUMENT SET, AND SHALL BE THE
ENGINEER OF RECORD FOR THE FIRE PROTECTION
SYSTEM.
3. THE FIRE PROTECTION SYSTEM SHALL BE DESIGNED
IN ACCORDANCE WITH NFPA, LOCAL CODES AND
ORDINANCES, AND FACTORY MUTUAL
REQUIREMENTS WHERE APPLICABLE.
FIRE PROTECTION NOTES:
MECHANICAL VENTILATION (NATURAL VENTILATION)
SPACE AREA SQ. FT.
CFM/SQ.FT.
OR ACH
AREA CFM PEOPLE CFM/PERSON PEOPLE CFM
Vbz (MAX OF
AREA AND
PEOPLE CFM)
ZONE
EFFECTIVENESS
Ez
ZONE
OUTDOOR
AIRFLOW (Voz)
Vot
ALL OCCUPIED
SPACES ON MAIN
AND UPPER LEVELS
SERVED BY OPERABLE WINDOWS, 4% OR GREATER IN FREE AREA OF FLOOR SPACE SERVED
BASEMENT
1,600 SQ.FT. x
9FT CEILINGS
0.35 ACH 84 8 15 120 120 0.8 150 150
PER
RESIDENCE
A/B SIDES
11.10.14
9 0% CD'S
FOUNDATION MEP PLAN
ME2.30
12.15.14
01.06.15
U ND ERG ROUND CDs
CONSTRUCTION DOCUM ENTS
BAS EMENT ADD ITION
02.06.15
S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100M000.dwg Printed By: cadd-drp February 06, 2015 - 11:33am LC-XXX
COPYRIGHT 2014
B
ANZE
G
EAUDIN
(970) 949-6108
(303) 278-3820
(970) 221-5691
(505) 323-9070
(307) 739-3944
Vail:
Denver:
Fort Collins:
Albuquerque:
Jackson:
www.bgce.com
MERIBEL CORP. RESIDENCE
Project Number - 1428
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
11/10/14
90% CD SET
09/05/14
PERMIT SET
7/30/14
DESIGN REVIEW
01/06/15
CD SET
M0.00
MECHANICAL
COVER
SHEET
04/15/15