HomeMy WebLinkAboutM010 SCHEDULES.pdfGRILLE, REGISTER, DIFFUSER & LOUVER SYMBOL USE PATTERN FINISH MANUFACTURER* & MODEL # ACCESSORIES REMARKS SIDEWALL SUPPLY/ RETURN LINEAR BAR FINISH FOR FIELD PAINTING KRUEGER 1600 CABLE OPERATED DAMPER WHERE AIRFLOW IS LISTED 15° DEFLECTION, 1/4" SPACING, 1/8" BAR THICKNESS, CONCEALED MNT'ING, FRAME RG CEILING SUPPLY/ RETURN/EXH LINEAR BAR FINISH FOR FIELD PAINTING KRUEGER 1600 CABLE OPERATED DAMPER WHERE AIRFLOW IS LISTED 15° DEFLECTION, 1/4" SPACING, 1/8" BAR THICKNESS, CONCEALED MNT'ING, FRAME RG FLOOR/SILL SUPPLY LINEAR BAR MEDIUM BRONZE KRUEGER 1850 O.B.D. 15° BLADE DEFLECTION, FRAME STYLE N, NO MOUNTING, 1/8" BARS, 1/4" SPACING; MITERED CORNERS AT INACTIVE AREAS FLOOR RETURN LINEAR BAR MEDIUM BRONZE KRUEGER 1850 - 0° BLADE DEFLECTION, FRAME STYLE N, NO MOUNTING, 1/8" BARS, 1/4" SPACING; MITERED CORNERS AT INACTIVE AREAS EXH/OSA STATIONAIRY RE: ARCH RUSKIN ELF6375DX BIRD SCREEN - MANUFACTURERS: GRD METALAIRE, TITUS LOUVER GREENHECK, L&D, SEIHO GENERAL NOTES: A: B: A B C D E EXHAUST FAN SCHEDULE MARK TYPE FAN MOTOR MANUFACTURER* & MODEL # ACCESSORIES REMARKS CFM SONES ESP HP/ (WATT) VOLT/ PHASE @ S.L. (IN WC) @ ALT (IN WC) EF-1 CEILING 75 0.5 0.35 0.25 12 W 120/1 PANASONIC FV-08VK3 BACKDRAFT DAMPER, ISOLATORS POWDER ROOMS-RES EF-2 CEILING 110 1.5 0.35 0.25 42 W 120/1 PANASONIC FV-20VQ3 BACKDRAFT DAMPER, ISOLATORS BATHROOMS-RES EF-3 CEILING 300 3.9 0.6 0.5 97 W 120/1 COOK GC720 BACKDRAFT DAMPER, FAN SPEED CONTROL ISOLATORS, GRILLE MECH/ELECT ROOMS EF-4 CEILING 200 2.0 0.3 0.2 64 W 120/1 PANASONIC FV-30VQ3 BACKDRAFT DAMPER, ISOLATORS GARAGES MANUFACTURERS: * COOK, GREENHECK, PENN GENERAL NOTES: A: B: FAN COIL SCHEDULE (HYDRONIC) MARK SERVICE TYPE FAN COOLING COIL HEATING COIL FILTER MANUFACTURER* & MODEL # ACCESSORIES REMARKS CFM O.S.A. CFM ESP ELECTRICAL AIR CONDITIONS WATER CONDITIONS AIR CONDITIONS WATER CONDITIONS @ S.L. (IN WC) @ ALT (IN WC) HP VOLT/ PH E.A.T. DB/WB (°F) L.A.T. DB/WB (°F) TOTAL MBH SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX.WTR P.D. (FT.) E.A.T. DB (°F) L.A.T. DB (°F) SENSIBLE MBH E.W.T. (°F) L.W.T. (°F) GPM MAX.WTR P.D. (FT.) FC-1A GAME ROOM HORIZ. 300 110 0.4 0.3 1/6 120/1 NO COOLING 34 95 8 140 110 0.6 10 2" TA CARRIER 42CE -SPACE FOR FUTURE 3-ROW CHILLED WATER COIL FC-2A BUNK ROOMS HORIZ. 200 50 0.5 0.4 1/6 120/1 NO COOLING 48 95 5 140 110 0.4 10 2" TA CARRIER 42CE -SPACE FOR FUTURE 3-ROW CHILLED WATER COIL FC-3A LIVING/ DINING HORIZ. 1,500 1,000 0.6 0.5 2 240/1 75/63 82/60^ 55/52 60/54^ 32 27 45 55 7.1 10 70/10^ 95/80^ 38/87^ 140 110 2.6/6.1^ 10 2" TA CARRIER 42BHE -4-ROW HEATING COIL; FUTURE COOLING PROVISIONS ONLY FC-4A MASTER 1 HORIZ. 600 0 0.4 0.3 (2) 1/12 120/1 75/63 55/52 11 9 45 55 2.7 10 70 95 12 140 110 1.0 10 2" TA CARRIER 42CE -FUTURE COOLING PROVISIONS ONLY FC-5A BED 1/ STAIRS HORIZ. 900 0 0.4 0.3 3/4 120/1 75/63 55/52 17 15 45 55 4.4 10 70 95 20 140 110 1.6 10 2" TA CARRIER 42BHE -FUTURE COOLING PROVISIONS ONLY FC-6A MASTER 2 HORIZ. 600 0 0.4 0.3 (2) 1/12 120/1 75/63 55/52 9 8 45 55 2.9 10 70 95 11 140 110 1.1 10 2" TA CARRIER 42CE -FUTURE COOLING PROVISIONS ONLY FC-7A BEDS 2/3 HORIZ. 400 0 0.5 0..4 1/6 120/1 75/63 55/52 8 7 45 55 1.8 10 70 95 10 140 110 0.7 10 2" TA CARRIER 42CE -FUTURE COOLING PROVISIONS ONLY FC-1B - - - - - - - - NO COOLING - - - - - - - - - - NOT USED FC-2B - - - - - - - - NO COOLING - - - - - - - - - - NOT USED FC-3B LIVING/ DINING HORIZ. 1,700 1,000 0.6 0.5 2 240/1 NO COOLING 70/16^ 95/80^ 40/90^ 140 110 2.8/6.3^ 10 2" TA CARRIER 42BHE - 4-ROW HEATING COIL FC-4B MASTER 1 HORIZ. 500 0 0.4 0.3 1/6 120/1 NO COOLING 70 95 8 140 110 0.7 10 2" TA CARRIER 42CE - - FC-5B BED 1 HORIZ. 300 0 0.4 0.3 1/6 120/1 NO COOLING 70 95 5 140 110 0.4 10 2" TA CARRIER 42CE - - FC-6B MASTER 2/ STAIRS HORIZ. 1,200 0 0.4 0.3 1/6 120/1 NO COOLING 70 95 21 140 110 1.7 10 2" TA CARRIER 42BHE - - FC-7B BEDS 2/3 HORIZ. 500 0 0.5 0.1 1/6 120/1 NO COOLING 70 95 10 140 110 0.7 10 2" TA CARRIER 42CE - - MANUFACTURERS: * WILLIAMS, ENVIROTEC, MCQUAY, TRANE GENERAL NOTES: A: ^ FIRST VALUE INDICATES NORMAL OPERATING CONDITIONS, SECOND VALUE INDICATES CONDITIONS DURING MAKEUP AIR OPERATION FOR KITCHEN HOOD. B: UNIT LEAKAGE TO BE <=2% OF DESIGN AIR FLOW. MISCELLANEOUS MECHANICAL EQUIPMENT SCHEDULE MARK SERVICE TYPE CAPACITY ELECTRICAL MANUFACTURER* & MODEL # ACCESSORIES REMARKS KW VOLT/ PH GF-1 BLDG. GLYCOL FEEDER GLYCOL FEEDER 6 GAL 50W 120/1 AXIOM IND. MF200 LOW PRESSURE ALARM PANEL - GF-2 SNOWMLET GLYCOL FEEDER GLYCOL FEEDER 6 GAL. 50W 120/1 AXIOM IND. MF200 LOW PRESSURE ALARM PANEL - SG-1 LL STEAM SHOWER STEAM SHOWER 925 CU. FT. 24 240/1 MR. STEAM MSSUPER5E ITEMPO PLUS CONTROLS, SHAPE AND FINISH BY ARCH - SG-2 ML MASTER SHOWER STEAM SHOWER 564 CU. FT. 12 240/1 MR. STEAM MSSUPER2E ITEMPO PLUS CONTROLS, SHAPE AND FINISH BY ARCH - SG-3 UL MASTER SHOWER STEAM SHOWER 613 CU. FT. 15 240/1 MR. STEAM MSSUPER3E ITEMPO PLUS CONTROLS, SHAPE AND FINISH BY ARCH - MANUFACTURERS: * STEAM SHOWERS: AMEREC, STEAMIST GENERAL NOTES: A: B: PLUMBING FIXTURE SCHEDULE SYMBOL TYPE A.D.A. FINISH MANUFACTURER* & MODEL # FAUCET TRIM MFR.* & MODEL # ACCESSORIES REMARKS FLOOR DRAIN NA CAST IRON ZURN Z415C -TRAP PRIMER CONNECTION 3" U.N.O. FLOOR SINK NA A.R.E. ZURN FD2376 -1 2 GRATE 3"Ø, U.N.O. ICE MAKER BOX NA WHITE GUY GRAY MIB1 -- - WASHER BOX NA WHITE GUY GRAY T200 -- - HOSE BIBB NA ROUGH BRONZE WOODFORD 19 - - ANTI-SIPHON, FREEZELESS DECK DRAIN NA CAST IRON ZURN ZN154-85 - UNDERDECK CLAMP MIN. 25 SQ. IN. FREE OPEN AREA; 3" U.N.O. CONFIRM DRAIN WITH WATERPROOFING ASSEMBLY DOWNSPOUT NOZZLE N/A STAINLESS STEEL ZURN Z199 - - SIZE TO MATCH PIPE SIZE HOT/COLD HOSE BIBB N/A ROUGH BRONZE WOODFORD V22 - -FREEZELESS, BACKFLOW PROTECTION POINT OF USE S/O INTERCEPTOR N/A CAST IRON ZURN Z1189-12 -- CAP AND SEAL VENT CONNECTION; NOT NEEDED FOR CONNECTION TO STORM MANUFACTURERS: DRAIN: JOSAM, WADE SMITH GENERAL NOTES: A: ALL LAVS, WATER CLOSETS, SHWRS/TUBS, AND ASSOCIATED ACCESSORIES ARE SPECIFIED BY THE ARCHITECT/INTERIORS. RE: ARCH FOR ADDITIONAL INFORMATION. B: P1 P2 P3 P4 P5 P6 P7 P8 P9 SNOWMELT MANIFOLD SCHEDULE ZONE DESCRIPTION APPROX. AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS MAX LOOP PRESSURE LOSS (FT) REMARKS 1A R.O.W. DRIVEWAY 70 0.8 1 1.1 - 2A DRIVEWAY 1,580 17.3 10 10.7 - 3A ENTRY 100 1.1 1 3.0 - 4A BBQ 65 0.7 1 1.0 - 5A MAIN MASTER DECK 120 1.3 1 5.0 - 6A SPA DECK 480 5.3 4 5.0 - 7A UPPER MASTER DECK 60 0.7 1 0.7 - 8A BEDROOMS DECK 110 1.2 1 3.9 - 1B R.O.W. DRIVEWAY 70 0.6 1 0.7 - 2B DRIVEWAY 1,890 15.5 12 6.3 - 3B ENTRY 310 2.6 2 6.1 - 4B BBQ 140 1.2 1 1.3 - 5B MAIN MASTER DECK 90 0.7 1 1.3 - 6B SPA DECK 560 4.6 4 4.6 - 7B UPPER MASTER DECK 60 0.5 1 0.4 - 8B BEDROOM DECK 50 0.4 1 0.3 - 9B BEDROOM DECK 50 0.4 1 0.3 - GENERAL NOTES: A: 3/4"Ø PEX-A TUBING, 9"O.C., 20°F ∆T, 85°F AVG. WATER TEMP B: 1. ALL STARTERS AND VFD'S FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED UNDER THIS CONTRACT AND SET IN PLACE AND WIRED BY EC. EACH SHALL BE OF ONE MANUFACTURER OR AVAILABLE THROUGH ONE MANUFACTURER TO FACILITATE EASE OF MAINTENANCE. 2. NOT ALL EQUIPMENT REQUIRED UNDER THIS CONTRACT IS NECESSARILY SPECIFIED ON THE SCHEDULE SHEETS. PLAN & DIAGRAM NOTATIONS AND PROJECT MANUAL CONTAIN EQUIPMENT SPECIFICATIONS AS WELL. 3. NOT ALL CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES REQUIRED ARE NECESSARILY INDICATED IN THE EQUIPMENT SCHEDULES. RE: PLANS AND SPECIFICATIONS FOR ADDITIONAL REQ'MTS. 4. CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES OF THE SCHEDULED EQUIPMENT ARE HEREBY INCORPORATED INTO THE PROJECT REQUIREMENTS. EQUIVALENT PRODUCTS PERFORMANCE AND CONSTRUCTION FEATURES SHALL MEET OR EXCEED THAT OF THE SPECIFIED EQUIPMENT WHETHER SCHEDULED OR NOT. 5. NOT ALL EQUIPMENT AVAILABLE FROM LISTED "EQUIVALENT" MANUFACTURERS LISTED IS NECESSARILY EQUIVALENT TO THE BASIS OF DESIGN EQUIPMENT SPECIFIED. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY COSTS, RESULTANT CHANGES TO OTHER DIVISIONS, AND SPATIAL REQ'MTS FOR EQUIPMENT OTHER THAN SCHEDULED. SCHEDULE NOTES: HOT WATER GENERATOR SCHEDULE MARK SERVIC E TYPE SIDE GPM FLUI D E.W.T . (°F) L.W.T . (°F) MAX PRESSU RE DROP (PSI) STORAG E CAPACIT Y (GAL.) MANUFACTURER* & MODEL # ACCESSORIES REMARKS WH-1 DHW VERTICA L, INDIREC T HOT 14 30% PG 180 160 5 114 LOCHINVAR SIT 119 HEAT TRAPS ON INLET AND OUTLET OF TANKS - COLD -WATE R 40 120 5 * GENERAL NOTES: A: B: HEAT RECOVERY VENTILATOR SCHEDULE MARK SERVICE TYPE ELECTRICAL FAN MANUFACTURER* & MODEL # ACCESSORIES REMARKS WATTS VOLT/ PH CFM FLA ESP @ S.L. (IN W.C.) @ ALT (IN W.C.) HRV-1 WHOLE HOUSE HORIZ. STATIC PLATE 160 120/1 150 1.5 0.4 0.3 RENEWAIRE EV200 - - MANUFACTURERS: *VENMAR GENERAL NOTES: A: CFM BASED ON (7) BEDROOMS, FLOOR AREA B/W 6,001 - 7,500SF B: S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100M010.dwg Printed By: cadd-drp February 06, 2015 - 11:33am LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET M0.10 MECHANICAL SCHEDULES 04/15/15