Loading...
HomeMy WebLinkAboutM020 SCHEDULES.pdfRADIANT MANIFOLD SCHEDULE ZONE DESCRIPTION APPROX. AREA (SQ. FT.) GPM ESTIMATED # OF LOOPS LOOP SPACING @ EXT.WALL MAX LOOP PRESSURE LOSS (FT) FLOOR COVERING REMARKS 1A GAME ROOM 530 0.5 3 6" 0.2 WOOD - 2A BAR/HALL 320 0.4 2 6" 0.4 WOOD - 3A STEAM SHOWER 120 0.3 1 6" 0.1 TILE - 4A BUNK ROOM 1 270 0.3 2 6" 0.2 CARPET PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 5A BUNK ROOM 2 280 0.3 2 6" 0.2 CARPET PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 6A LIVING/ KITCHEN 765 1.6 4 6" 3.5 WOOD - 7A ENTRY/MUD 185 0.3 1 6" 0.3 WOOD/STONE PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 8A MASTER 1 320 0.7 2 6" 1.2 WOOD - 9A MASTER BATH 1 100 0.3 1 6" 0.3 TILE - 10A GARAGE 540 1.0 3 6" 1.6 CONCRETE - 11A BEDROOM 1 210 0.5 1 6" 1.2 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 12A MASTER 2 300 0.7 2 6" 0.9 WOOD - 13A MASTER BATH 2 120 0.3 1 6" 0.3 WOOD - 14A BEDROOM 2 230 0.5 2 6" 0.5 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 15A BEDROOM 3 210 0.5 1 6" 1.2 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 16A LAUNDRY/ UPPER HALL 185 0.4 1 6" 0.9 WOOD - 1B GAME ROOM 475 0.4 3 6" 0.1 WOOD - 2B BAR/HALL 375 0.4 2 6" 0.5 WOOD - 3B STEAM SHOWER 100 0.3 1 6" 0.1 TILE - 4B BUNK ROOM 1 200 0.3 1 6" 0.2 CARPET - 5B BUNK ROOM 2 265 0.3 2 6" 0.1 CARPET - 6B LIVING/ KITCHEN 575 1.2 3 6" 2.7 WOOD - 7B ENTRY/MUD 300 0.7 2 6" 0.9 WOOD/STONE - 8B MASTER 1 265 0.6 2 6" 0.7 WOOD - 9B MASTER BATH 1 110 0.3 1 6" 0.2 TILE - 10B GARAGE 525 0.9 3 6" 1.5 CONCRETE - 11B BEDROOM 1 260 0.6 2 6" 1.0 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 12B MASTER 2 245 0.5 2 6" 0.9 WOOD - 13B MASTER BATH 2 165 0.3 1 6" 0.2 WOOD - 14B BEDROOM 2 220 0.5 2 6" 0.4 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 15B BEDROOM 3 220 0.5 2 6" 0.4 WOOD PROVIDE IND. LOOP IN BATH FOR COMFORT BALANCING 16B LAUNDRY/ UPPER HALL 230 0.5 2 6" 0.4 WOOD - GENERAL NOTES: A: 20° ∆T, 250 FT LOOP LENGTH, 5/8"Ø TUBING, 9" O.C. SPACING B: AIR COOLED CHILLER SCHEDULE MARK TYPE DUTY CAPACITY (TONS) AMBIENT TEMP. DB (°F) L.W.T. (°F) E.W.T. (°F) GPM HEAD LOSS (FT.) ELECTRICAL CONDENSING FAN MANUFACTURER* & MODEL # ACCESSORIES REMARKS MCA VOLT/ PH MOCP QUANTITY CFM CH-1 MODULAR 10 85 45 55 27 - 66.25 240/1 100 2 6,600 MULTISTACK ASP010X - - MANUFACTURERS: * MULTIAQUA GENERAL NOTES: A: B: BOILER SCHEDULE MARK SERVICE BOILER TYPE FUEL TYPE HEATING CAPACITY L.W.T. (°F) E.W.T. (°F) BURNER VENT TYPE MANUFACTURER* & MODEL # ACCESSORIES REMARKS INPUT @ S.L. (MBH) OUTPUT @ ALT. MINIMUM A.F.U.E. HP VOLT/ PH B-1 BLDG HEAT CONDEN. NATURAL GAS 400 318 95% 180 150 15A 120/1 PVC LOCHINVAR WHN399 ACID NEUTRALIZATION KIT HIGH ALTITUDE MANUFACTURERS: * TRIANGLE TUBE, PATTERSON KELLY, VIESSMANN OR BUDERUS GENERAL NOTES: A: B: HEAT EXCHANGER SCHEDULE MARK SERVICE TYPE SIDE GPM FLUID E.W.T. (°F) L.W.T. (°F) MAX PRESSURE DROP (FT) FOULING FACTOR HEAT TRANSFER (MBH) MANUFACTURER* & MODEL # ACCESSORIES REMARKS HX-1A SNOWMELT FLAT PLATE HOT 42 30%PG 140 120 5 0.0001 400 TACO TFP10x20L-20 (1-1/2"TMPT) -- COLD 30 50%PG 70 100 5 HX-1B SNOWMELT FLAT PLATE HOT 50 30%PG 140 120 5 0.0001 475 TACO TFP10x20L-24 (1-1/2"TMPT) -- COLD 36 50%PG 70 100 5 HX-2 SPA FLAT PLATE HOT 26 30%PG 140 120 5 0.0001 250 TACO TMPN5x12-100 (1-1/4"MPT) -- COLD 50 SPA 104 114 5 MANUFACTURERS: * B&G, PATTERSON-KELLY, TACO, TRANTER GENERAL NOTES: A: B: PUMP SCHEDULE MARK SERVICE TYPE GPM TDH (FT) FLUID MOTOR MANUFACTURER* & MODEL # ACCESSORIES REMARKS HP VOLT/ PH P-1 BOILER INJECTION INLINE 28 25 30%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-2 HEATING WATER CIRC INLINE 30 35 30%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-3 DWH INJECTION INLINE 28 25 30%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-4 DHW RECIRC INLINE 3 12 POTABLE 1/25 120/1 GRUNDFOS UP 15-18 B7 - ALL BRONZE CONSTRUCTION P-5A SNOWMELT INJECTION INLINE 42 25 30%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-5B SNOWMELT INJECTION INLINE 50 25 30%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-6A SNOWMELT CIRC INLINE 30 35 50%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-6B SNOWMELT CIRC INLINE 36 35 50%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-7 SPA HX INJECTION INLINE 20 25 30%PG 1/2 120/1 GRUNDFOS UPS 32-80/2 - - P-8 CHILLER INJECTION INLINE 25 25 50%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- P-9 CHILLED WATER CIRC INLINE 20 40 50%PG 3/4 120/1 GRUNDFOS UPS 32-160/2 -- SP-1 SEWAGE EJECTOR SUBMER. 5 30 WASTE 1/2 120/1 ZOELLER - - SP-2 SEWAGE EJECTOR SUBMER. 15 30 WASTE 1/2 120/1 ZOELLER - - MANUFACTURERS: * B&G, TACO OR AURORA EQUIVALENT GENERAL NOTES: A: B: WINE ROOM SPLIT SYSTEM SCHEDULE INDOOR FAN COIL UNIT OUTDOOR CONDENSING UNIT ACCESSORIES REMARKS MARK CFM ESP AIR CONDITIONS ELECTRICAL MANUFACTURER* & MODEL # MARK DUTY CAPACITY (TONS) AMBIENT TEMP. DB (°F) LOW AMB. CONTROL DB (°F) ELECTRICAL MANUFACTURER* & MODEL # @ S.L. (IN WC) @ ALT (IN WC) E.A.T. DB/WB (°F) L.A.T. DB/WB (°F) TOTAL MBH SENSIBLE MBH W MCA/ MOCP VOLT/ PH MCA VOLT/ PH MOCP FC-8A/B 220 0.15 0.1 55/47 50/45 2.2 2.2 75 2.0/ 15 120/1 WINE GUARDIAN SS025 CU-1 1/2 85 40 10.7 120/11 5 WINE GUARDIAN M2FH-0039-IAA-0H2 ROOM MOUNTED COMBINATION T-STAT/H-STAT; HUMIDIFIER - MANUFACTURERS: * WINE ENTHUSIAST GENERAL NOTES: A: B: 1. ALL STARTERS AND VFD'S FOR MECHANICAL EQUIPMENT SHALL BE FURNISHED UNDER THIS CONTRACT AND SET IN PLACE AND WIRED BY EC. EACH SHALL BE OF ONE MANUFACTURER OR AVAILABLE THROUGH ONE MANUFACTURER TO FACILITATE EASE OF MAINTENANCE. 2. NOT ALL EQUIPMENT REQUIRED UNDER THIS CONTRACT IS NECESSARILY SPECIFIED ON THE SCHEDULE SHEETS. PLAN & DIAGRAM NOTATIONS AND PROJECT MANUAL CONTAIN EQUIPMENT SPECIFICATIONS AS WELL. 3. NOT ALL CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES REQUIRED ARE NECESSARILY INDICATED IN THE EQUIPMENT SCHEDULES. RE: PLANS AND SPECIFICATIONS FOR ADDITIONAL REQ'MTS. 4. CAPACITIES, CHARACTERISTICS, AND CONSTRUCTION FEATURES OF THE SCHEDULED EQUIPMENT ARE HEREBY INCORPORATED INTO THE PROJECT REQUIREMENTS. EQUIVALENT PRODUCTS PERFORMANCE AND CONSTRUCTION FEATURES SHALL MEET OR EXCEED THAT OF THE SPECIFIED EQUIPMENT WHETHER SCHEDULED OR NOT. 5. NOT ALL EQUIPMENT AVAILABLE FROM LISTED "EQUIVALENT" MANUFACTURERS LISTED IS NECESSARILY EQUIVALENT TO THE BASIS OF DESIGN EQUIPMENT SPECIFIED. CONTRACTOR SHALL BE SOLELY RESPONSIBLE FOR ANY COSTS, RESULTANT CHANGES TO OTHER DIVISIONS, AND SPATIAL REQ'MTS FOR EQUIPMENT OTHER THAN SCHEDULED. SCHEDULE NOTES: 182 WEST MEADOW DRIVE VAIL, CO 81657 PIETRINI RESIDENCE Project Number - 1428 07/30/14 DESIGN REVIEW COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com 09/05/14 PERMIT SET M0.20 MECHANICAL SCHEDULES 03/04/15