HomeMy WebLinkAboutM200 BASEMENT PIPING.pdfNOTES: SCALE: BASEMENT PIPING PLAN 3/16" = 1'-0" T T T T 2/1 T T CHR CHS 3/4" HWS/R UP TO . CHR CHS RADIANT ZONE #3B RADIANT ZONE #2B RADIANT ZONE #1B RADIANT ZONE #2A RADIANT ZONE #3A RADIANT ZONE #1A 3/4" HWS/R UP TO . 3/4" HWS/R UP TO . 3/4" HWS/R UP TO 3/4" HWS/R UP TO FLOOR ABOVE. 3/4" HWS/R TO . 3/4" HWS/R TO . 3/4" HWS/R TO . 1"HWS/R VALVED AND CAPPED FOR FUTURE BASEMENT LOOPS. 3/4" HWS/R UP TO 3/4" HWS/R UP TO 1-1/2" HWS/R, 2" CHS/R UP TO FLOOR ABOVE. 3/4" HWS/R, 3/4" CHS/R TO CAP CHS/R LINES FOR FUTURE USE. 3/4" HWS/R UP TO 1" HWS/R TO 3/4"HWS/R UP TO 2" HWS/R, 2" CHS/R CAPPED, 1" SMS/R, 1-1/2" CW, 1-1/4" HW, 3/4" HWC TO BOILER PLANT, DOMESTIC WATER ENTRY, AND DOMESTIC HOT WATER PLANT. 1-1/4" HWS/R, 1-1/2" CHS/R TO CAP CHS/R LINES FOR FUTURE USE. CHR CHS 3/4" HWS/R TO . 3/4" HWS/R TO . 3/4" HWS/R TO 3/4" HWS/R UP TO . 3/4" HWS/R UP TO . 1"SMS/R TO SNOWMELT MANIFOLD #6B. 3/4"SMS/R TO SNOWMELT MANIFOLD #4B. 3/4"SMS/R UP TO SNOWMELT MANIFOLD #5B. 3/4"SMS/R UP TO SNOWMELT MANIFOLD #5A. 3/4"SMS/R UP TO SNOWMELT MANIFOLD #4A. 3/4" SMS/R UP TO SNOWMELT MANIFOLD #3A. 4"W TO MAIN. I.E. = 8139.00' 2" COMBINED F/CW FROM MAIN. I.E. = 8139.50' 4"W TO MAIN. 3/4" SMS/R TO SNOWMELT MANIFOLDS #3B. 2" COMBINED F/CW FROM MAIN. 4"G UP. 1-1/4" CW, 1-1/4" HW, 3/4" HWC UP TO FLOOR ABOVE. 1-1/4" CW, 1-1/4"HW, 3/4" HWC TO BATH AND LAUNDRY GROUPS, CDBBC. 1-1/4" CW, 1-1/4" HW, 3/4" HWC TO FLOOR ABOVE. 1" CW, 3/4" HW, 3/4" HWC TO KITCHEN FIXTURE GROUP, CDBBC. 1. RE: M4 SERIES FOR PIPING DIAGRAMS. 2. COORDINATE ROUTING OF CONDENSATE DRAIN LINES WITH ARCHITECT PRIOR TO INSTALLATION. 3. PIPING ON EXTERIOR WALLS TO BE ROUTED IN FRAMED WALL ON INTERIOR SIDE OF INSULATION. 4. AVOID ROUTING PIPING OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 5. PROVIDE FLEXIBLE PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 6. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 7. PEX PIPING SHALL NOT BE ALLOWED TO PENETRATE FIRE BARRIERS WHERE FIRE CAULKING IS REQUIRED. 8. ALL BRANCH CHILLED AND HEATING WATER PIPING TO FAN COIL UNITS SHALL BE 3/4" U.N.O. 9. ALL VALVES SHALL BE INSTALLED WITH ACCESS PANELS IN HARD-LID CEILINGS. 10. ALL PIPING SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER PIPES, DUCTS, AND ELECTRICAL. 11. ACCESS PANELS SHALL BE 24x24, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH THE LOCATIONS OF THE EQUIPMENT OR APPARATUS THAT THEY SERVE. 12. REFER TO THE PLUMBING FIXTURE CONNECTION SCHEDULE FOR PIPE SIZES TO INDIVIDUAL FIXTURES. 13. NOT ALL REQUIRED CLEANOUTS ARE NECESSARILY SHOWN ON THESE PLANS. PROVIDE CLEANOUTS ON WASTE, VENT AND STORM PIPING AS REQUIRED BY CODE AND FOR REASONABLE MAINTENANCE BASED ON ACTUAL FIELD INSTALLATION. COORDINATE LOCATIONS WITH ARCHITECT/ENGINEER. 14. ST PIPING 3", U.N.O. 15. ROUTE DOMESTIC HOT WATER RECIRC TO WITHIN 10 FEET OF ALL HOT WATER FIXTURES. CONNECT WITHIN 5 FEET OF 0.5 GPM AND LOWER FAUCETS. 16. PROVIDE NECESSARY CW SUPPLY TO STEAM GENERATOR PER MANUFACTURER'S REQUIREMENTS. 17. ROUGH-IN NECESSARY 1/2"CW SUPPLY WITH SHUT-OFF VALVE, CAPPED FOR FUTURE HUMIDIFICATION SYSTEMS AT "A" UNIT PER MANUFACTURER'S REQUIREMENTS. LOCATE AT EACH FCU LOCATION FROM NEAREST CW MAIN OF 3/4" OR LARGER SIZE. PROVIDE 1" DRAIN PIPE WITH AIR GAP TO SAME LOCATION AND ROUTE INDIRECTLY TO NEAREST FLOOR DRAIN OR SINK TAILPIPE. G UP TO RANGE. G UP TO FIREPLACE. G UP TO BBQ. G UP TO FIREPLACE. G UP TO BBQ. G UP TO RANGE. 1"CW, 1"HW, 3/4"HWC TO BATHROOM GROUP, CDBBC. G G G G TO OUTDOOR FIREPLACE. ROUTE PIPING BELOW GRADE I.A.W. 2012 IFGC, BREAK GRADE AS REQUIRED. G SPACE RESERVED FOR COMBINED FIRE/DOMESTIC WATER ENTRIES. SPACE RESERVED FOR COMBINED FIRE/DOMESTIC WATER ENTRIES. G UP. G G G 1"SMS/R UP TO SNOWMELT MANIFOLD #6A. G TO OUTDOOR FIREPLACE. G TO BOILERS. 3/4" SMS/R UP. 2"CHS/R CAPPED AND VALVED FOR FUTURE CHILLER PLANT INSTALLATION. CHS CHR 4"ø RADON PIPE RISER. 4"ø RADON PIPE UP. STUB PIPING INTO SUB-SLAB ASSEMBLY I.A.W. 2012 IRC, APPENDIX F, AF103.6. 4"ø RADON PIPE UP. STUB PIPING INTO SUB-SLAB ASSEMBLY I.A.W. 2012 IRC, APPENDIX F, AF103.6. 1-1/2" SMS/R UP TO SNOWMELT MANIFOLDS #1A & 2A 1-1/2" SMS/R UP TO SNOWMELT MANIFOLDS #1B & 2B. RADIANT ZONE #4B P1 P1 P1 2" HWS/R, 2" SMS/R TO BOILER PLANT. 1-1/2" CW, 1-1/4"HW, 3/4"HWC TO DOMESTIC WATER ENTRY AND DOMESTIC HOT WATER PLANT. G UP TO BOILERS. 1-1/2" HWS/R, 3/4" SMS/R UP. G UP. 3/4" ROUTE PIPING BELOW GRADE, I.A.W. 2012 IFGC; BREAK GRADE AS REQUIRED. 3"V UP AND CAPPED FOR FUTURE EXTENSION. 2/1 4"W TO BATH GROUP, CDBBC. 4"W UP. 2-1/2"V DN. ROUTE TO 3"V UP, CDBBC. 2"PW UP TO GRAVITY MAIN. 1 FLAG NOTES: 2 3 T 3"W UP TO KITCHEN GROUP; CDBBC. 2 2 2 3 3 2"PW UP TO GRAVITY MAIN. 2 2 1 2 T V 2"V DN. 3"V CAPPED FOR FUTURE EXTENSION. 3"V UP. 3"W UP TO KITCHEN GROUP ABOVE. 3/4" HWS/R TO 1 3 3 1-1/4" HWS/R UP TO SMS SMR HWR HWS SMS SMR SMS SMR HWR HWS HWR HWS SMS SMR SMS SMR HWR HWS HWR HWS SMS SMR SMS SMR SMS SMR W W W W W W W 3/4" 3/4" 3/4" 3/4" 1-1/4" 1" 3/4" 3/4" 3/4" 3/4" 1" 1" 3/4" 3/4" 1-1/4" 3/4" 1-1/4" 3/4" 3/4" 2" 2" 1-14" 1-1/4" 1" 1" 3/4" 1-1/2" 1-1/2" 3/4" 3/4" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/2" 1-1/4" 4" 4" 4" 4" 1-1/4" 1-1/4" 1-1/2" 1-1/2" 1-1/4" 1-1/4" 1 3/4" 1-1/4" 1-1/4" 4"G UP. 2" 2" RADIANT ZONE #4A 4 4 1-1/4" HWS/R AND 1-1/4"CHS/R VALVED AND CAPPED FOR FUTURE BASEMENT LOADS. 1 1-1/4" 1" P1 1-1/4" 1-1/4" CW, 1-1/4"HW, 3/4" HWC TO BATHROOM GROUP, CDBBC. 3/4"CW, 3/4"HW, 3/4"HWC TO LAUNDRY GROUP, CDBBC. 1"CW, 1"HW, 3/4"HWC TO BATHROOM GROUP, CDBBC. CHS CHR 3/4"CW UP TO HB. 3/4"CW UP TO HB. ST 3" ST 3" ST 3" 3"ST TO MAIN. 3"ST TO MAIN. 3"ST TO P9, TYP. 3"ST TO MAIN. S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100M200.dwg Printed By: cadd-drp February 06, 2015 - 11:33am LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET M2.00 BASEMENT PIPING PLAN 04/15/15