HomeMy WebLinkAboutM300 BASEMENT HVAC.pdfNOTES: SCALE: BASEMENT MECHANICAL PLAN 3/16" = 1'-0" 1. RE: M4 SERIES FOR MECHANICAL DIAGRAMS. 2. COORDINATE ROUTING OF CONDENSATE DRAIN LINES WITH ARCHITECT PRIOR TO INSTALLATION. 3. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS. 4. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 5. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 6. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 7. ALL SOURCES OF IGNITION ON MECHANICAL EQUIPMENT SHALL BE MOUNTED 18" AFF. 8. T-STATS SHALL BE LOCATED NEAR THE LIGHT SWITCH WITHIN THE ROOM SHOWN. COORDINATE WITH ARCHITECT & ELECTRICAL ENGINEER TO MATCH HEIGHT AND LOCATION. 9. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER DUCTS, PIPES, AND ELECTRICAL. 10. ACCESS PANELS SHALL BE SIZED TO ALLOW REMOVAL OF LARGEST APPLIANCE, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH THE LOCATIONS OF THE EQUIPMENT OR APPARATUS THAT THEY SERVE. 11. FIREPLACE FLUE ROUTING, SIZING, TYPE, ETC. BY OTHERS. 12. PROVIDE GRAVITY DAMPERS ON ALL OSA INTAKES AND EXH AT EXTERIOR PENETRATION THAT CLOSE WHEN VENTILATION SYSTEM IS NOT OPERATING. 13. PROVIDE CABLE OPERATED BALANCE DAMPER AT ALL SA GRILLES. 14. CONFIRM ANY TJI PENETRATION LIMITATIONS WITH STRUCTURAL PRIOR TO INSTALLATION. 18x4 SA UP. 4"ø BOILER FLUE AND COMBUSTION AIR UP, TYP. 3 PAIRS. 1 FLAG NOTES: 1 28x12 RA/OSA UP. HEATING WATER EXP. TANK. SNOWMELT EXP. TANK. 12"ø EXH UP. DHW EXP. TANK. , QTY. 2, STACKED. HEATING WATER EXP. TANK. SNOWMELT EXP. TANK. , QTY. 2, STACKED. 12"ø EXH UP. DHW EXP. TANK. SPACE RESERVED FOR FUTURE COOLING SYSTEM ANCILLARY EQUIPMENT. 1 4"ø DRYER EXH UP 4"ø DRYER EXH UP AND CAPPED FOR FUTURE EXTENSION. 7"ø 7"ø 7"ø 28x12 IN SOFFIT 7"ø ROUTE SA BRANCHES IN JOIST CAVITIES, TYP. 12x6 SA PLENUM UP, TYP. 11. 28x12 60x8 RA UP. 28x12 38x10 22x12 IN SOFFIT 7"ø 12x6 SA PLENUM UP, TYP. 10. 8"ø 18x4 SA UP. 7"ø 24x6 RA UP. 48x6 RA UP. 10"ø 7"ø 24x4 7"ø 7"ø 7"ø A 100 12x4 A 30 12x4 5"ø A RA 18x4 A 30 12x4 10"ø EXH DUCT STUBBED INTO A/V CLOSET FOR FUTURE USE. 10"ø EXH DUCT STUBBED INTO A/V CLOSET FOR FUTURE USE. 10"ø 12"ø 10"ø 7"ø A 50 12x4 12x8 A 150 12x4 5"ø 7"ø 12x8 A RA 18x4 7"ø A RA 24x4 A 100 12x4 TYP. 3 10"ø 10"ø E O SA 24 x 1 8 20x18 9"ø 9"ø 9"ø 9"ø 7"ø 7"ø 7"ø 7"ø 8"ø 7"ø 8"ø 7"ø 7"ø 7"ø 7"ø 6x12 OSA UP. ROUTE ALL ROUND DUCTS IN THIS AREA ABOVE CEILING. 9"ø ROUTE ALL ROUND DUCTS IN THIS AREA ABOVE CEILING. OSA MOTORIZED DAMPER ACCESSIBLE FROM LOUVER FACE 30x12 RA UP 4 4 12x6 OSA UP. 7"ø 7"ø 7"ø 7"ø 7"ø 7"ø 20x4 7"ø 4"ø 9"ø 10"ø 6"ø 7"ø 24x15 DN C:\Users\eng-bpl\local settings\temp\AcPublish_7436\951100M300.dwg Printed By: eng-bpl June 25, 2015 - 4:33pm LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET 05/06/15 ASI-004 4 06/25/15 MECH UPDATE M3.00 BASEMENT MECHANICAL PLAN 07/14/15