MAIN FLOOR MECHANICAL PLAN
3/16" = 1'-0"
A
RA
48x6
A
500
48x6
A
600
48x6
A
RA
48x6
E
OSA
24x18
1. RE: M4 SERIES FOR MECHANICAL DIAGRAMS.
2. COORDINATE ROUTING OF CONDENSATE DRAIN LINES
WITH ARCHITECT PRIOR TO INSTALLATION.
3. CEILING COORDINATION OF ALL MEP SYSTEMS
(LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL,
FIRE PROTECTION, ETC.) MUST BE COMPLETED BY
THE CONTRACTOR PRIOR TO THE START OF ANY
INSTALLATIONS.
4. AVOID ROUTING DUCTWORK OVER ELECTRICAL
ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C.
CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16
CONTRACTOR.
5. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO
ALL MOTORIZED EQUIPMENT.
6. VERIFY ALL EQUIPMENT ACCESS PANELS WITH
MANUFACTURER AND ARCHITECT.
7. ALL SOURCES OF IGNITION ON MECHANICAL
EQUIPMENT SHALL BE MOUNTED 18" AFF.
8. T-STATS SHALL BE LOCATED NEAR THE LIGHT SWITCH
WITHIN THE ROOM SHOWN. COORDINATE WITH
ARCHITECT & ELECTRICAL ENGINEER TO MATCH
HEIGHT AND LOCATION.
9. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS
POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST
SPACE WHEN POSSIBLE, ESPECIALLY WHERE
CROSSING OTHER DUCTS, PIPES, AND ELECTRICAL.
10. ACCESS PANELS SHALL BE SIZED TO ALLOW
REMOVAL OF LARGEST APPLIANCE, U.N.O. LOCATIONS
SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL
BE COORDINATED WITH THE ARCHITECTS DRAWINGS
AND WITH THE LOCATIONS OF THE EQUIPMENT OR
APPARATUS THAT THEY SERVE.
11. FIREPLACE FLUE ROUTING, SIZING, TYPE, ETC. BY
OTHERS.
12. PROVIDE GRAVITY DAMPERS ON ALL OSA INTAKES
AND EXH AT EXTERIOR PENETRATION THAT CLOSE
WHEN VENTILATION SYSTEM IS NOT OPERATING.
13. PROVIDE CABLE OPERATED BALANCE DAMPER AT
ALL SA GRILLES.
14. CONFIRM ANY TJI PENETRATION LIMITATIONS WITH
STRUCTURAL PRIOR TO INSTALLATION.
10"ø KITCHEN EXH TO
MANUFACTURER'S REMOTE EXH
FAN.
30x12 RA DN.
16x10
7"ø
6"ø
E
EXH
24x24
12"ø EXH DN.
6"ø
9"ø
16x10
18x10
18x10
E
EXH
24x24
E
EXH
12x12
8"ø
9"ø EXH DN.
12x6
14"ø EXH DN.
8"ø
E
OSA
12x12
6"ø
18x4 SA DN. w/
1/2" LINER.
4" BOILER FLUE AND COMBUSTION
AIR RISERS, TYP. 3 PAIRS. LOCATE
ON WARM SIDE OF INSULATION.
28x12
RA/OSA DN.
20x12
4"ø DRYER EXH DN.
TERMINATE WITH
WALL CAP.
4"ø DRYER EXH DN.
TERMINATE WITH
WALL CAP.
4"ø DRYER EXH DN.
A
235
18x4
E
EXH
12x12
A
1,700
48x12
C
115
12x6
TYP. 11
ACTIVE SUPPLY GRILLE LENGTH
SHOWN, PROVIDE CONTINUOUS
FLOOR GRILLE WITH INACTIVE
PORTIONS PER ARCHITECT. C
145
12x6
TYP. 10
18x4 SA DN. w/
1/2" LINER.
A
1500
60x10
A
250
18x4
ACTIVE SUPPLY GRILLE LENGTH
SHOWN, PROVIDE CONTINUOUS
FLOOR GRILLE WITH INACTIVE
PORTIONS PER ARCHITECT.
8"ø
10"ø KITCHEN EXH TO
MANUFACTURER'S REMOTE
EXH FAN. MAINTAIN 10'
CLEARANCE TO OSA INTAKE
AND 3' CLEARANCE TO
OPENINGS ONTO BULIDING
RA MOTORIZED DAMPER ACCESSIBLE
FROM RETURN AIR GRILLE
OSA MOTORIZED DAMPER
ACCESSIBLE FROM LOUVER
FACE
RA MOTORIZED
DAMPER ACCESSIBLE
FROM RETURN AIR
GRILLE
12x5 OSA DN.
7"ø
4
4
8"ø
7"ø
12"ø
12"ø EXH DN.
IN CHASE
12"ø
C:\Users\eng-bpl\local settings\temp\AcPublish_7436\951100M310.dwg Printed By: eng-bpl June 25, 2015 - 4:33pm LC-XXX
COPYRIGHT 2014
B
ANZE
G
EAUDIN
(970) 949-6108
(303) 278-3820
(970) 221-5691
(505) 323-9070
(307) 739-3944
Vail:
Denver:
Fort Collins:
Albuquerque:
Jackson:
www.bgce.com
MERIBEL CORP. RESIDENCE
Project Number - 1428
1650 Fallridge Road, Suite C-1
Vail, Colorado 81657
f.(970) 476-4901 p.(970)476-6342
182 WEST MEADOW DRIVE
VAIL, CO 81657
11/10/14
90% CD SET
09/05/14
PERMIT SET
7/30/14
DESIGN REVIEW
01/06/15
CD SET
05/06/15
ASI-004
4
06/25/15
MECH UPDATE
M3.10
MAIN FLOOR
MECHANICAL
PLAN