Loading...
HomeMy WebLinkAboutM310 MAIN HVAC.pdfNOTES: SCALE: MAIN FLOOR MECHANICAL PLAN 3/16" = 1'-0" A RA 48x6 A 500 48x6 A 600 48x6 A RA 48x6 E OSA 24x18 1. RE: M4 SERIES FOR MECHANICAL DIAGRAMS. 2. COORDINATE ROUTING OF CONDENSATE DRAIN LINES WITH ARCHITECT PRIOR TO INSTALLATION. 3. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS. 4. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 5. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 6. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 7. ALL SOURCES OF IGNITION ON MECHANICAL EQUIPMENT SHALL BE MOUNTED 18" AFF. 8. T-STATS SHALL BE LOCATED NEAR THE LIGHT SWITCH WITHIN THE ROOM SHOWN. COORDINATE WITH ARCHITECT & ELECTRICAL ENGINEER TO MATCH HEIGHT AND LOCATION. 9. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER DUCTS, PIPES, AND ELECTRICAL. 10. ACCESS PANELS SHALL BE SIZED TO ALLOW REMOVAL OF LARGEST APPLIANCE, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH THE LOCATIONS OF THE EQUIPMENT OR APPARATUS THAT THEY SERVE. 11. FIREPLACE FLUE ROUTING, SIZING, TYPE, ETC. BY OTHERS. 12. PROVIDE GRAVITY DAMPERS ON ALL OSA INTAKES AND EXH AT EXTERIOR PENETRATION THAT CLOSE WHEN VENTILATION SYSTEM IS NOT OPERATING. 13. PROVIDE CABLE OPERATED BALANCE DAMPER AT ALL SA GRILLES. 14. CONFIRM ANY TJI PENETRATION LIMITATIONS WITH STRUCTURAL PRIOR TO INSTALLATION. 10"ø KITCHEN EXH TO MANUFACTURER'S REMOTE EXH FAN. 30x12 RA DN. 16x10 7"ø 6"ø E EXH 24x24 12"ø EXH DN. 6"ø 9"ø 16x10 18x10 18x10 E EXH 24x24 E EXH 12x12 8"ø 9"ø EXH DN. 12x6 14"ø EXH DN. 8"ø E OSA 12x12 6"ø 18x4 SA DN. w/ 1/2" LINER. 4" BOILER FLUE AND COMBUSTION AIR RISERS, TYP. 3 PAIRS. LOCATE ON WARM SIDE OF INSULATION. 28x12 RA/OSA DN. 20x12 4"ø DRYER EXH DN. TERMINATE WITH WALL CAP. 4"ø DRYER EXH DN. TERMINATE WITH WALL CAP. 4"ø DRYER EXH DN. A 235 18x4 E EXH 12x12 A 1,700 48x12 C 115 12x6 TYP. 11 ACTIVE SUPPLY GRILLE LENGTH SHOWN, PROVIDE CONTINUOUS FLOOR GRILLE WITH INACTIVE PORTIONS PER ARCHITECT. C 145 12x6 TYP. 10 18x4 SA DN. w/ 1/2" LINER. A 1500 60x10 A 250 18x4 ACTIVE SUPPLY GRILLE LENGTH SHOWN, PROVIDE CONTINUOUS FLOOR GRILLE WITH INACTIVE PORTIONS PER ARCHITECT. 8"ø 10"ø KITCHEN EXH TO MANUFACTURER'S REMOTE EXH FAN. MAINTAIN 10' CLEARANCE TO OSA INTAKE AND 3' CLEARANCE TO OPENINGS ONTO BULIDING RA MOTORIZED DAMPER ACCESSIBLE FROM RETURN AIR GRILLE OSA MOTORIZED DAMPER ACCESSIBLE FROM LOUVER FACE RA MOTORIZED DAMPER ACCESSIBLE FROM RETURN AIR GRILLE 12x5 OSA DN. 7"ø 4 4 8"ø 7"ø 12"ø 12"ø EXH DN. IN CHASE 12"ø C:\Users\eng-bpl\local settings\temp\AcPublish_7436\951100M310.dwg Printed By: eng-bpl June 25, 2015 - 4:33pm LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET 05/06/15 ASI-004 4 06/25/15 MECH UPDATE M3.10 MAIN FLOOR MECHANICAL PLAN 07/14/15