Loading...
HomeMy WebLinkAboutM320 UPPER HVAC.pdfNOTES: SCALE: SECOND FLOOR MECHANICAL PLAN 3/16" = 1'-0" A 200 24x6 A 200 24x6 ARA 24x 6 ARA24x 6 A 600 48x6 A RA 48x6 A RA 48x6 A 600 48x6 A 300 24x6 A RA 24x6 A 250 24x6 A 250 24x6 A RA 24x6 A RA 24x6 A 150 12x6 A 600 36x8 A RA 36x8 A 300 24x6 A RA 24x6 1. RE: M4 SERIES FOR MECHANICAL DIAGRAMS. 2. COORDINATE ROUTING OF CONDENSATE DRAIN LINES WITH ARCHITECT PRIOR TO INSTALLATION. 3. CEILING COORDINATION OF ALL MEP SYSTEMS (LIGHTING, DUCTWORK, DIFFUSERS, ELECTRICAL, FIRE PROTECTION, ETC.) MUST BE COMPLETED BY THE CONTRACTOR PRIOR TO THE START OF ANY INSTALLATIONS. 4. AVOID ROUTING DUCTWORK OVER ELECTRICAL ROOMS OR ELECTRICAL PANELS; MAINTAIN N.E.C. CLEARANCES. COORDINATE ROUTINGS WITH DIV. 16 CONTRACTOR. 5. PROVIDE FLEXIBLE DUCT AND PIPE CONNECTIONS TO ALL MOTORIZED EQUIPMENT. 6. VERIFY ALL EQUIPMENT ACCESS PANELS WITH MANUFACTURER AND ARCHITECT. 7. ALL SOURCES OF IGNITION ON MECHANICAL EQUIPMENT SHALL BE MOUNTED 18" AFF. 8. T-STATS SHALL BE LOCATED NEAR THE LIGHT SWITCH WITHIN THE ROOM SHOWN. COORDINATE WITH ARCHITECT & ELECTRICAL ENGINEER TO MATCH HEIGHT AND LOCATION. 9. ALL DUCTWORK SHALL BE ROUTED AS HIGH AS POSSIBLE IN THE CEILING SPACE. UTILIZE JOIST SPACE WHEN POSSIBLE, ESPECIALLY WHERE CROSSING OTHER DUCTS, PIPES, AND ELECTRICAL. 10. ACCESS PANELS SHALL BE SIZED TO ALLOW REMOVAL OF LARGEST APPLIANCE, U.N.O. LOCATIONS SHOWN ARE APPROXIMATE, EXACT LOCATIONS SHALL BE COORDINATED WITH THE ARCHITECTS DRAWINGS AND WITH THE LOCATIONS OF THE EQUIPMENT OR APPARATUS THAT THEY SERVE. 11. FIREPLACE FLUE ROUTING, SIZING, TYPE, ETC. BY OTHERS. 12. PROVIDE GRAVITY DAMPERS ON ALL OSA INTAKES AND EXH AT EXTERIOR PENETRATION THAT CLOSE WHEN VENTILATION SYSTEM IS NOT OPERATING. 20x12 7"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 12"ø 9"ø 12"ø 20x12 18x10 18x10 6"ø 7"ø 14x10 14x10 8"ø 8"ø 7"ø 7"ø 8"ø 8"ø 8"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 4"ø DRYER EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 12"ø 24x12 9"ø 9"ø 7"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 16x10 16x10 6"ø 8"ø 8"ø 7"ø 8"ø 8"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 7"ø 10"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 7"ø 6"ø 9"ø 9"ø A 300 24x6 A 300 24x6 4"ø DRYER EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. 4" BOILER FLUE AND COMBUSTION AIR THRU ROOF. LOCATE ON WARM SIDE OF INSULATION. TERMINATE VIA MANUFACTURER'S CONCENTRIC VENT KIT; MAINTAIN CLEARANCES TO COMBUSTIBLES, OPENINGS, AND OTHER INTAKE I.A.W. MANUFACTURER'S REQUIREMENTS. ZONE DAMPERS. ZONE DAMPERS. 10"ø EXH UP THRU ROOF. TERMINATE VIA GOOSENECK. A RA 12x6 A 150 12x6 7"ø 7"ø 7"ø 10"ø E OSA 12x12 E OSA 12x12 BDD 7"ø 7"ø 7"ø ZONE DAMPERS. BY-PASS DAMPER. BDD 24x12 A RA 36x8 9"ø 9"ø 12"ø 7"ø OSA C:\Users\eng-bpl\local settings\temp\AcPublish_7796\951100M320.dwg Printed By: eng-bpl July 27, 2015 - 7:23am LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET 05/06/15 ASI-004 4 06/25/15 MECH UPDATE M3.20 2ND FLOOR MECHANICAL PLAN 08/10/15