HomeMy WebLinkAboutM400 DIAGRAMS.pdfWALL CLEANOUT DIAGRAM NO SCALE 1'-0" MAY EXTEND AS A WASTE OR VENT. CHROME WALLCOVER AND SCREW. PLUGGED TEE WITH CLEANOUT. WALL. FLOOR LINE. 1/8 C.I. BEND. BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. MIN. HEIGHT PER MFR. BALL VALVE TAKE-OFF FROM TOP OF CW PIPE TRAP PRIMER VALVE, SIOUX CHIEF PRIME PERFECT OR EQUAL. DISTRIBUTION UNIT (FOR MULTIPLE DRAINS) 1 2 " TYPE K SOFT COPPER LINE(S) TO FLOOR DRAIN(S). QUANTITY AS REQUIRED. NO JOINTS BELOW GRADE. 1/2" DIAGRAM TRAP PRIMER CONNECTION NO SCALE FLOOR A DUPLEX SEWAGE EJECTOR DIAGRAM NO SCALE VENT INSTALL OFFSETS & UNIONS TO ALLOW COVER REMOVAL. CHECK VALVE GASKETED COVER. CONTINUE PER PLANS. CHECK VALVE CONCRETE-CAST AROUND BASIN. (MIN 4" THICK) FIBERGLASS BASIN. EJECTOR PUMPS. HIGH WATER ALARM LEVEL (AND BOTH PUMPS ON). GATE VALVES CONTINUE PER PLANS. HEAVY DUTY ACCESS COVER. GOOSENECK VENT. PUMP CONTROL PANEL WITH ALTERNATOR. MOUNT ON WALL AT 5'-0" A.F.F. (TO BOTTOM). DEPTH AS REQUIRED TO MEET INLET PIPE. NOTE: SEE PLANS FOR SIZE. E CLEANOUT DIAGRAMS FLOOR CLEANOUT (FCO) NO SCALE SLOPE DN @ 1/4"/L.F. CLEANOUT TO GRADE (COTG) WASTE LINE FINISHED GRADE 6" ADJUSTABLE GRADE CLEANOUT AND ACCESS ENCLOSURE WITH ANCHOR FLANGE, HEAVY DUTY TOP, AND VANDAL PROOF FASTENERS, ZURN, Z-1400-HD-KBRASS CLEANOUT PLUG W/COUNTER SUNK HEAD. ADJUSTABLE CLEANOUT AND ACCESS COVER ZURN ZB-1400. TOP OF COVER TO BE FLUSH W/ TOP OF FLOOR. 16" CONC. PAD TROWEL SMOOTH & EDGE. 1/8 C.I. BEND BALANCE OF PIPING SAME AS CLEANOUT TO GRADE. FLOOR LINE 1/8 C.I. BEND C.I. WASTE LINE. LGTH TO SUIT. 1/8 BEND IF CLEANOUT OCCURS AT END OF LINE. PROVIDE FOLLOWING OPTIONS AS APPROPRIATE CARPET MARKER - FOR CARPETED AREAS. SQUARE TOP - FOR CERAMIC TILE OR SIMILAR SQUARE PATTERN FLOOR. FLASHING CLAMP - FOR ABOVE GRADE WATER PROOFED AREAS. G ISLAND VENT DIAGRAM NO SCALE DRAINBOARD 2" SLOPE 2" W V FLOOR REQUIREMENTS C.O. SLOPE 1. EXTEND VENT AS HIGH AS POSSIBLE BUT NOT LESS THAN THE DRAINBOARD HEIGHT & THEN RETURNING IT DOWNWARD & CONNECTING IT TO THE HORIZONTAL SINK DRAIN IMMEDIATELY DOWNSTREAM FROM THE VERTICAL FIXTURE DRAIN. 2. THE RETURNED VENT SHALL BE CONNECTED TO THE HORIZONTAL DRAIN THRU A Y-BRANCH FITTING & SHALL, IN ADDITION, BE PROVIDED WITH A FOOT VENT TAKEN OFF THE VERTICAL FIXTURE VENT BY MEANS OF A Y-BRANCH IMMEDIATELY BELOW THE FLOOR & EXTENDING TO THE NEAREST PARTITION & THEN THRU THE ROOF OR CONNECTED TO OTHER VENTS, IN AN APPROVED MANNER. 3. DRAINAGE FITTINGS SHALL BE USED ON ALL PARTS OF THE VENT BELOW THE FLOOR & A MIN. SLOPE OF 1/4"/FT BACK TO THE DRAIN SHALL BE MAINTAINED. 4. THE RETURN DRAIN UNDER THE DRAINBOARD SHALL BE A ONE PIECE FITTING OR AN ASSEMBLY OF A 45°, A 90°, & A 45° IN THE ORDER NAMED. 5. THE ISLAND SINK DRAIN, UPSTREAM OF THE RETURNED VENT, SHALL SERVE NO OTHER FIXTURES. VENT LINE NEAREST PARTITION. WALL CLEANOUT 11 2" 11 2" SINK DRAIN TO BUILDING SEWER. C NO SCALE FS D D F TO FIRE PROTECTION SYSTEMS. CONTINUATION BY F.P. DESIGN/BUILDC CONTRACTOR. TEST VALVE; PIPE TO OUTSIDE. FLOW SWITCH TO ALARMS, SEE SPECS. DRAIN VALVE; PIPE INDIRECT TO FLOOR DRAIN PER NFPA REQUIREMENTS, TYP. SHUT-OFF VALVE. DOUBLE CHECK TYPE BACKFLOW PREVENTER. TAMPER SWITCHES ON VALVES. FIRE SERVICE FLANGE. FLOOR SINK C.W. SERVICE FIRE ENTRY PIPING DIAGRAM DIAGRAM SHOWN FOR REFERENCE ONLY, CONFIRM FINAL REQUIREMENTS WITH FIRE PROTECTION DESIGN BUILD CONTRACTOR AND ENGINEER OF RECORD. PIPE THRU ROOF DIAGRAM NO SCALE 6" MIN. 24 GA. GALV. ROOF JACK W/ 6" FLANGE BY M.C., SET IN PLASTIC CEMENT BY G.C. PIPE BY M.C. 24 GA. GALV. STORM COLLAR BY M.C., CLAMP IN PLACE & CAULK WEATHERTIGHT. FINISHED ROOF FELTS BY G.C. SOLDERED LAP SEAM PIPE SLEEVE & CAULKING BY M.C. 2" MIN. ROOF 2 LAYERS OF FELT BY G.C. COOR'D ROOF PENETRATION AND SEALING WITH ROOF MANUFACTURER.AND INSTALLING CONTRACTOR. B DRAIN THRU WALL DIAGRAM SANITARY OR STORM BLDG. SLOPE 1/4"/L.F. NO SCALE C.O.T.G. BASEMENT WALL. COORDINATE WALL OPENING SIZE WITH PIPE MATERIAL AND SIZE AND MANUFACTURER REQUIREMENTS. STORM OR SANITARY BLDG. DRAIN. LINK-SEAL OR EQUIVALENT. GRADE FAN COIL UNIT INSTALLATION NO SCALE SA FAN COIL UNIT D OSA FILTER W/ ACCESS PANEL. ACOUSTICAL LINING. VOLUME DAMPER. RA DUCT. CONDENSATE DRAIN. PIPE INDIRECT TO APPROVED RECEPTOR (PROVIDE MIN. 2" DEEP TRAP). SHEET METAL DRAIN PAN, EQUIPPED WITH UL508 WATER-LEVEL DETECTION DEVICE THAT WILL SHUT-OFF EQUIPMENT. ROUND HANGER ROD TYP. WITH EXCEPTION OF FAN COILS LOCATED IN ATTIC. SPRING VIBRATION ISOLATORS, TYP. DOUBLE LOCKNUT. 1. RETURN AIR PLENUM FULL SIZE OF UNIT CONNECTION. CEILING MOTORIZED DAMPER. RADIANT/SNOWMELT MANIFOLD PIPING DIAGRAM NO SCALE TO ASSOCIATED THERMOSTAT (RADIANT) OR TEMP/MOISTURE SENSOR (SNOWMELT). MANIFOLD BOX (WALL MOUNTED FOR RADIANT; LOCATED IN SLAB OR LANDSCAPE BOX FOR SNOWMELT). MANUFACTURER'S MANIFOLD ASSY. LOOP BALANCE/ISOLATION VALVE MANUFACTURER'S MANIFOLD ASSEMBLY WITH REVERSE RETURN PIPING. RADIANT/SNOWMELT TUBING. LOOP QUANTIITY AS REQUIRED. 1. PROVIDE MANUFACTURER'S MANIFOLDS AND ISOLATION VALVES WITH PIPING. 2. FOR EXTERIOR MANIFOLD LOCATIONS PROVIDE WATERPROOF MANIFOLD BOX OR WATERPROOF CONTROL VALVE. TO PIPING MAINS AIR VENT AT HIGH POINTS, TYPICAL. MANIFOLD BALANCE VALVE. L K F J WATER ENTRANCE DIAGRAM F M NO SCALE SEE FIRE ENTRY DIAGRAM, THIS SHEET. 2" LINE (VERIFY WITH FIRE PROTECTION CONTRACTOR). DOMESTIC WATER SERVICE SHUT-OFF VALVE. 3/4" IRRIGATION LINE WITH APPROVED REDUCED PRESSURE BACKFLOW PREVENTION DEVICE. (VFY. WITH IRRIGATION CONTRACTOR). 1-1/2" CW TO BUILDING. REDUCED PRESSURE TYPE BACKFLOW PREVENTER. CERTIFIED TESTER TO TEST. 1" WATER METER WITH REMOTE READOUT. PRESSURE REDUCING VALVE, TYP. WATTS 223, 1" SET @ 60 PSI 2" CW/FIRE SERVICE (VERIFY SIZE WITH FIRE PROTECTION CONTRACTOR). : WATER METER AND BACKFLOW PREVENTER MUST BE MOUNTED HORIZONTALLY. D METER BYPASS. H S:\BGProjects\9511.00 182 West Meadow Drive Duplex\Cad\BGCE CAD\951100M400.dwg Printed By: cadd-txc January 06, 2015 - 10:25am LC-XXX COPYRIGHT 2014 B ANZE G EAUDIN (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com MERIBEL CORP. RESIDENCE Project Number - 1428 1650 Fallridge Road, Suite C-1 Vail, Colorado 81657 f.(970) 476-4901 p.(970)476-6342 182 WEST MEADOW DRIVE VAIL, CO 81657 11/10/14 90% CD SET 09/05/14 PERMIT SET 7/30/14 DESIGN REVIEW 01/06/15 CD SET M4.00 MECHANICAL DIAGRAMS 04/15/15