HomeMy WebLinkAboutB14-0366 Balance Report.pdfTEST, ADJUST AND BALANCE REPORT \3 -I~ -03 "~ PROJECT SMARTWOOL VAIL #1115 PREPARED FOR AMERICAN PLUMBING, HEATING, & SOLAR INC. REPORT ISSUE DATE 11/17/2014 PREPARED BY HVAC TAB lie P.O. BOX 1926 VAIL, CO 81658 PHONE: 970-376-5198 E-MAIL: mrichardson@hvactab.co HVAC TAB lie TEST, ADJUST AND BALANCE REPORT THE DATA PRESENTED IN THIS REPORT IS AN EXACT RECORD OF SYSTEM PERFORMANCE AND WAS OBTAINED IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS. ANY VARIANCES FROM THE DESIGN REQUIREMENTS ARE NOTED THROUGHOUT THIS REPORT. THE RESULTS SHOWN AND INFORMATION PRESENTED IN THIS REPORT IS CERTIFIED TO BE ACCURATE AND COMPLETE, TO THE EXTENT POSSIBLE BY EQUIPMENT AND PROCEDURES USED THROUGH- OUT THIS SURVEY. THE FINAL AIR DISTRIBUTION SYSTEM MEASUREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING, ADJUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIEDBY:M~ DATE: THE FINAL HYDRONIC DISTRIBUTION SYSTEM MEA&LREMENTS ARE IN COMPLIANCE WITH NBC PROCEDURAL STANDARDS FOR TESTING, ADUSTING AND BALANCING OF ENVIRONMENTAL SYSTEMS AND THE PROJECT SPECIFICATIONS. CERTIFIED BY: DATE: ----------------- HVAC TAB lie WARRANTS IHA T THE AIR AND HYDRONIC SYSTEM EVALUATED DURING THIS SURVEY IS OPERATING AT THE SPECIFIED LEVELS AS SHOWN WITHIN THIS REPORT, AT AND ONLY AT THIS TIME. HVAC TAB lie MAKES NO OTHER WARRANTIES, ST A TED OR IMPLIED, CONCERNING THE CONTINUED PERFORMANCE, OPERATION OR SAFETY IN THE USE OF THIS EQUIPMENT PASS THIS TIME. CERTIFIED Michael T. Richardson HVAC TAB, lie Page: 1 #13--084-03 Expires: 2/2212015 NATIONAL BA!ANCING COUNCIL HVAC TAB lie DATE: 11/17/2014 PROJECT : SMARTWOOL VAIL PROJECT ALTITUDE: "HG INSTRUMENT/ SERIAL# APPLICATION DATE OF USE SHORTRIDGE ADM-870C I #M0921 l AIR FLOW READINGS 11/17/2014 ANEMOMETER#RVA501416001 AIR FLOW READINGS 11/17/2014 SHORTRIDGE FLOW HOOD Alf FLOW READINGS NOT USED TH-720 HYGROMETER/ #TH7200950003 AIR TEMP I HUMIDITY NOT USED PITOT TUBE 18" PRES. READINGS NOT USED PITOT TUBE 24" PRES. READINGS NOT USED PITOT TUBE 36" PRES. READINGS NOT USED PITOT TUBE 48" PRES. READINGS NOT USED SHIMPO TACHOMETER I #CI05B0010 RPM READINGS 11/15/2014 FLUKE 375 I #21290229 VOLT I AMP 11/15/2014 SHORTRIDGE HDM-2501 #W08162 WATER PRES. READINGS NOT USED ASCROFT I 0-100 PSI I #D068332-06 WATER PRES. READINGS NOT USED FLUKE 52-11 #99780167 TEMP. READINGS NOT USED REFRACTOMETER RHA-100 I #RHA-GLYCOL% READINGS NOT USED 100 INSTRUMENT CAl1IBRATION REPORT CALIBRATION CALIBRATION DATE DUE DATE 06/1212014 06101212015 04/1412014 0411412015 * * 0610412014 0610412015 NIA NIA NIA NIA NIA NIA NA NA 0611812014 0611812015 0610412014 0610412015 0611212014 0611212015 * * 021312014 021312015 NIA NIA * CHECKED TO CALIBRATED METER REMARKS: ALL READINGS WITH SHORTRIDGE INSTRUMENTS ARE CORRECTED FOR TEMPERATURE AND ALTITUDE. PAGE: HVAC TAB lie DATE: 11/15/2014 PROJECT: SMARTWOOL VAIL AIR HANDLER UNIT DATA MANUFACTURER INTERNATIONAL ENVIROMENTAL CORP MODEL HBC1200051645 SERIAL 96-1451-10-1 FAN TYPE CENTRIFUGAL RATING/OUTLET TOTAL 1000CFM@0.6"ESP MIN OSACFM 168 CFM STARTER DATA MANUFACTURER NONE MODEL NONE SIZE/THERMAL NO. NONE RANGE (AMPS) NONE SET AT (AMPS) NONE REQ. THERMAL NONE RATING (AMPS) NONE AIRFLOW DATA SUPPLY CFM 971 OSACFM 169 RETURN CFM 802 F -0.05" L T E R NOTES: AIR APPARATUS TEST REPORT SYSTEM: FCU-C2-14 MOTOR NAMEPLATE DATA MANUFACTURER BALDOR HP R.P.M. 1/2 1725 PHASE FRAME 1 56 S.F. TYPE 1.25 - VOLTS AMPS 115/230 8.4/4.2 THERMALLY PROTECTED - DRIVE DATA MOTOR DRIVE 1 VP 3 5/8" MOTOR BORE 5/8" FAN DRIVE 1AK54 FAN BORE 3/4" NO. BEL TS & SIZE 1 I A 25 ROTATION CORRECT CENTERLINE MOTOR ADJ PULLEY SPEED+ 2 6 3/4" + 1/2 -1/2 TURNS TEST DATA INITIAL FINAL FAN R.P.M. 994 994 VOLTAGE 120 120 AMPERAGE 7.8 7.8 0.02" PAGE: HVACTAB lie DATE: 11/17/2014 PROJECT: SMARTWOOL VAIL SYSTEM TERMINAL DESIGN NO TYPE SIZE AK VEL CFM FCU-C2-14 1 SR 46/2 115 2 SR 46/2 188 3 SR 46/2 188 4 SR 46/2 188 5 SR 46/2 188 6 --- 7 SR 11/11 110 8 SR 11 /11 25 1002 NOTES: NF DENOTES NOT FOUND AIR TERMINAL TEST REPORT SYSTEM: FCU-C2-14 INITIAL FINAL NOTES VEL CFM VEL CFM 152 109 246 179 108 185 176 177 196 174 NF NF NOT FOUND 165 113 40 34 DAMPER r1 ns:Pn 1083 971 TOTAL PAGE: