HomeMy WebLinkAboutLoad Calc.pdfDanici Electric, Inc.
PO Box 7246 ~ Breckenridge, CO 80424
Phone (970) 390-1173 ~ Fax (970) 547-9221
sparky63@danicielectric.com
Sept 19, 2014
Attn: Jim and Tommy Gregg
Gregg & Co Builders
PO Box 526
Wolcott, CO 81655
Office: (970) 926-2378
The following are Load Calculations for 421 Beaver Dam Cir, Vail, CO 81657:
General Lighting 18,000VA
Small Appliance 3,000VA
Laundry 1,500VA
TOTAL 22,500VA
3,000VA at 100% 3,000VA
22,500VA – 3,000VA 19,500VA
19,500VA at 35% 6,825VA
NET LOAD 9,825VA
Range 8,000VA
Oven 8,000VA
Dryer (X 2) 11,000VA
Hot Tub 8,000VA
Jetted Tub 2,500VA
Heat Tape 3,000VA
Add’l Small Appliance 3,000VA
Steamer 8,000VA
NET CALCULATED LOAD 61,325VA
61,325VA /240V = 256A
256A TOTAL LOAD CALC
400A Service is Required
Respectfully,
David Novak