HomeMy WebLinkAboutB14-0374 load calcs.pdf~/ •J7'--.... Residential Standard Calculation 9/25/1997 \..___ MANOR VAIL UNIT #167 Version 2010 G STEP 1 Article 220.42 & 220.52 [Sq. ft .... =:Fl 644 General Lighting load 1,932 VA SHEARON ELECTRIC P.O. BOX43 AVON, COLORADO 81620 970-949-6456 g 0 0 2 Small Appliance 3,000 VA 1 Laundry circuit 1,500 VA Gen.Lgt, Sm App.& Laun. Load 6,432 VA 3,000 VA 3,432 VA VA STEP 2 Article 220.50 & 220.51 0 @100%= @ 35%= @ 25%= 3,000VA 1,201 VA VA 10/2212014 8:02 General Lighting Demand Load 4,201 VA Heat Pump w/ Concurrent Supplementary Heating QTY Total 0 HP #1 -. VA AHU 1 Select -. HP #2 .. HP #3 .. HP #4 .. HP #5 .. STEP 3 4,500 VA .. 1,400 VA • 600VA • 1,030 VA • 690VA • 400VA • 1,200 VA • 1,440 VA • 170 VA • 400VA • 6,670 VA • VA AHU2 Select VA AHU3 Select VA AHU4 Select VA AHU 5 Select Article 220.53 STEP 4 Article 220.54 Electric Clothes Dryers STEP 5 Article 220.55 Electric Ranges or Number of appliances 0 Check Box for Gas Range .. .. .. .. VA Qty .. VA Qty .. VA Qty .. VA Qty .. VA Qty .. VA 1,400 VA VA 1,030 VA 690VA 400VA 1,200 VA VA VA VA 6,670 VA VA 667VA 506VA VA VA VA VA 100% Demand 2,500 VA Apply Demand Heating Load HP Load Greater of Heat@ 100% vs.AJC@ 100% Appliance Demand Load Dryer Demand Load Range Demand Load Service Demand Demand Load Neutral Demand Min.Service Req. Min. Feeder size Min. Neutral size Eq. Grding Cond. VA 13,172 VA VA 3,200 VA 20,573 VA 86A 71 A 100A 4 4 8 0 Copper 2,500 VA Apply Demand Total Appliance Load 17,563 VA Col C demand Cooktop Cooktop Oven(s) Oven(s) 4 or more demand@ 75% plus 100% demand loads 13,172 VA 8,000W 4,000 W Col B demand Col B demand Col B demand Col B demand HEAT TAPE CIRCUITS Number of appliances 1 Dem. Factor 80% 3,200W Cooktop & Oven Demand Load jmp1 jds@comcast.net >>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>>><<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<<< Pool Panel Feeder Calculation (See Note) A B N Continuous Non-continuous Continuous Motors 0 .... 0 0 0 Motors Motors Non-continuous 0 ..... 0 0 0 select ..p 240v select .. 0 Spa heater 11 kVA ...... 0 0 select ..p 240v select .. 0 Pool heater 3. 5 ton ...... 0 0 select -.b 240v select .. 0 Pool heater 5 ton ...... 0 0 select .. ti 240v select .. 0 Pool Light select I• 0 . . . . . . 0 0 0 select ·ti 240v select • 0 Blower select I• oD 240v 0 0 0 2012 240v 240v 240v 240v 240v other load OD 240v 0 0 0 I 0.0 I Motor Neutral Load other load oo 240v 0 0 0 0 Min.Copper Pool Feeder AWG A A A Max.Unbalanced Neutral Load Minimum Panel Rating A Phase Amperes Neut. load