HomeMy WebLinkAboutE0.1.pdf1. DO NOT SCALE DRAWINGS. VERIFY DIMENSION IN FIELD PRIOR TO COMMENCEMENT OF WORK. REFER TO ARCHITECTURAL DRAWINGS FOR ALL DIMENSIONS. 2. SUBCONTRACTOR SHALL BE RESPONSIBLE TO NOTIFY PRIME CONTRACTOR OF DISCREPANCIES PRIOR TO STARTING ANY WORK. 3. PROVIDE DEMOLITION AS SHOWN. IF AFFECTED, RESTORE CONTINUITY TO DEVICES TO REMAIN. 4. DEVICES ONLY SHOWN IF AFFECTED BY SCOPE OF WORK. ALL OTHER ELECTRICAL SYSTEMS (NOT SHOWN) EXISTING TO REMAIN. NOTES: PROVIDE ELECTRICAL CONNECTION TO NEW BOILER. HOMERUN CIRCUIT TO PANELBOARD SERVING EXISTING BOILER ELECTRICAL. FIELD-COORDINATE. REMOVE ELECTRICAL CONNECTION TO EXISTING BOILER FOR DEMOLITION. EXISTING CIRCULATION PUMPS, TO REMAIN. TYPICAL 2. RESTORE CONTINUITY OF CIRCUIT TO PUMPS IF AFFECTED BY BOILER DEMOLITION. 1 FLAG NOTES: 3 2 P - S T P - S T B 1 S T 111 B - 333 222 1. ELECTRICAL WIRING SHALL BE 75C RATED MC-TYPE CABLE (2)#12AWG+#12AWG GRD. FINAL CONNECTION TO BOILER MAY BE 75C RATED THWN IN LIQUIDTIGHT FLEXIBLE PATHWAY. CONDUIT OR PATHWAY MAY NOT BE USED AS EQUIPMENT GROUND. 2. EQUIPMENT DISCONNECT SHALL BE 20A/240v/1P TOGGLE SWITCH WITH THERMAL PROTECTION, RATED FOR MOTOR USE. MOUNT IN ACCESSIBLE LOCATION ON WALL ADJACENT TO BOILER. PROVIDE ADHESIVE TYPEWRITTEN LABEL INDICATING CIRCUIT, VOLTAGE, PHASE AND EQUIPMENT DESIGNATION. MOUNT AT +48"AFF. 3. BRANCH CIRCUIT BREAKERS SHALL BE OF PANEL MANUFACTURER, 20A/1P, 10kAIC, HACR-RATED. PROVIDE UPDATED TYPEWRITTEN PANEL SCHEDULE. 4. DEMOLITION: REMOVE ALL ELECTRICAL COMPONENTS (PATHWAYS, JUNCTION BOXES, WIRING, DEVICES, ETC.) ASSOCIATED WITH EQUIPMENT TO BE REMOVED. DISPOSE OF DEMOLISHED COMPONENTS PER INDUSTRY STANDARDS AND ENVIRONMENTAL REGULATIONS. 5. NEW WORK: COORDINATE ALL WORK WITH OWNER. FIELD-COORDINATE ELECTRICAL CONNECTION TO EQUIPMENT WITH MECHANICAL CONTRACTOR. WORK SHALL BE PERFORMED IN A WORKMANLIKE MANNER TO THE SATISFACTION OF THE OWNER. PROVIDE ALL NECESSARY ACCESSORIES OR APPURTENANCES REQUIRED FOR A COMPLETE INSTALLATION, EVEN IF NOT DIRECTLY INDICATED ON THIS DRAWING. COMPLY WITH MANUFACTURER'S REQUIREMENTS FOR INSTALLATION; REPLACE ANYTHING DAMAGED BY INCORRECT FIELD WIRING OR ELECTRICAL INSTALLATION. VERIFY OPERATION OF NEW ELECTRICAL WORK PRIOR TO TURNOVER. 6. LOAD JUSTIFICATION: REMOVED LOAD: LESS THAN 12A (EXISTING BOILER NAMEPLATE) ADDED LOAD: 5.3A (NEW BOILER AND INTEGRAL INJECTION PUMP NAMEPLATE) EXPECTED LOAD CHANGE: NEGLIGIBLE TO PANEL CAPACITY ELECTRICAL SPECS: GFCI DUPLEX RECEPTACLE DUPLEX RECEPTACLE; HALF SWITCHED WALL MOUNTED SPECIAL OUTLET AS NOTED SPECIAL OUTLET AS NOTED JUNCTION BOX WALL MOUNTED JUNCTION BOX FLOOR MOUNTED JUCTION BOX DUPLEX RECEPTACLE MOUNTED ABOVE CONTER C DIVISION 15 EQUIPMENT POWER CONNECTION FUSED DISCONNECT NON FUSED DISCONNECT MOTOR STARTER TRANSFORMER PANELBOARD OR LOADCENTER CONTACTOR ELECTRIC MOTOR CIRCUIT HOMERUN CONDUIT RUN CONDUIT RUN BELOW GRADE CONDUIT UP CONDUIT DOWN TIMER SWITCH SWITCH THREE-WAY SWITCH FOUR-WAY SWITCH DOOR JAMB SWITCH KEY SWITCH VARIABLE SPEED SWITCH THERMAL OVERLOAD SWITCH INDICATES DEMOLITION. NOTE: LIGHT LINEWEIGHT INDICATES EXISTING. NOTE: ALL SYMBOLS SHOWN ON LEGEND ARE NOT NECESSARILY USED. ABBREVIATIONS AVC - ABOVE FINISHED CEILING AFF - ABOVE FINISHED FLOOR AFG - ABOVE FINISHED GRADE AL - ALUMINUM BFG - BELOW FINISH GRADE C - CONDUIT CKT - CIRCUIT CT - CURRENT TRANSFORMER EM - EMERGENCY EWC - ELECTRIC WATER COOLER (E) - EXISTING FBO - FURNISHED BY OWNER GRD - GROUND GFI - GROUND FAULT CIRCUIT INTERRUPTER IG - ISOLATED GROUND IAW - IN ACCORDANCE WITH NIC - NOT IN CONTRACT DW - DISHWASHER DISP - GARBAGE DISPOSAL NL - NIGHT LIGHT NTS - NOT TO SCALE REF - REFRIGERATOR TVSS - TRANSIENT VOLTAGE SURGE SUPPRESSOR UG - UNDERGROUND UNO - UNLESS NOTED OTHERWISE WP - WEATHER PROOF XP - EXPLOSION PROOF +18" - MOUNTING HEIGHT TO CENTERLINE OF DEVICE ABOVE FINISH FLOOR S T S V S K S J S 4 S 3 S TS C T N - - J J J ELECTRICAL LEGEND POWER SYMBOLS SINGLE RECEPTACLE DUPLEX RECEPTACLE DOUBLE DUPLEX RECEPTACLE SCALE: ELECTRICAL FLOOR PLAN 1/8" = 1'-0" VAIL, COLORADO 81657 09.24.14 SHEET TITLE: NO. Job no.: REVISION Drawn by: Date: Designed by: DATE BY 846 FOREST ROAD EAUDIN ANZE COPYRIGHT 2014 B G C:\Users\cadd-txc\local settings\temp\AcPublish_7968\953800E01.dwg Printed By: cadd-txc September 24, 2014 - 1:09pm LC-XXX Vail: Denver: Fort Collins: Albuquerque: Jackson: www.bgce.com (970) 949-6108 (303) 278-3820 (970) 221-5691 (505) 323-9070 (307) 739-3944 9538.00 E0.1 ELECTRICAL SYSTEMS PLAN ELR ELR 10/20/14