Loading...
HomeMy WebLinkAboutXtrodinaire 3615.pdf3615 HO GSR2 (with screen) Installation Manual WARNING: If the information in these instructions is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. - Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. - WHAT TO DO IF YOU SMELL GAS · Do not try to light any appliance. · Do not touch any electrical switch; do not use any phone in your building. · Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. · If you cannot reach your gas supplier, call the fire department. - Installation and service must be performed by a qualified installer, service agency or the gas supplier. HOT GLASS WILL CAUSE BURNS DO NOT TOUCH GLASS UNTIL COOLED NEVER ALLOW CHILDREN TO TOUCH GLASS A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. Tested and Listed by Report # G100866538PRT-001 ANSI Z21.88a-2014 CSA 2.33a-2014 x Built-In Direct Vent Fireplace x Natural Gas or Propane x Residential or Mobile Home This appliance may be installed in an aftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by local codes. This appliance is only for use with the type of gas indicated on the rating plate. A conversion kit is supplied with the appliance. INSTALLER: Leave this manual with the appliance. CONSUMER: Retain this manual for future reference. Travis Industries, Inc. 12521 Harbour Reach Dr., Mukilteo, WA 98275 www.travisproducts.com ¤ Copyright 2014, T.I. $10.00 4140731 100-01372 Same size as exisintg. Flue must terminate in a fire rated shaft per IBC 2012 10/31/14 2 Introduction © Travis Industries 4140731 100-01372 Overview This manual details the installation requirements for the 3615 HO GSR2 fireplace. For operating and maintenance instructions, refer to the 3615 HO GSR2 Owner's Manual (part # 100-01373). Listing Details This appliance was listed by Intertek Test Labs to ANSI Z21.88. The listing label is attached to the appliance near the gas control valve. A copy is shown to the right. Massachusetts Approval This manual has been submitted to the Massachusetts Board of State Examiners of Plumbers and Gas Fitters. National Fireplace Institute Report No. 100866538PRT-001 Control No. 4000515 Vented Gas Fireplace Heater 3615 GSR2 Tested to: ANSI Z21.88-2014/CSA 2.33-2014 “Vented Gas Fireplace Heater”, CGA 2.17-M91 (R2009) “Gas BurningHeating Appliances for Manufactured Homes”, and CSA P.4.1-09 Testing method for measuring annual fireplace efficiency. This appliance must be installed in accordance with local codes, if any; if none, follow the National Fuel Gas Code, ANSI Z223.1/NFPA 54, or Natural Gas and Propane Installation Codes, CSA B149.1. This appliance must be installed in accordance with the current Standard CAN/CSA Z240 MH, Mobile Housing,in Canada or with the Manufactured Home Constructions and Safety Standard, Title 24 CFR, Part 3280, in theUnited States, or when such a standard is not applicable, ANSI/NCSBCS A225.1/NFPA 501A, Manufactured Home Installation Standard. This vented gas fireplace heater is equipped at the factory for use with natural gas. If conversion to propane (LP) is desired, the optional factory conversion kit must be used. Part No. 250-02897 register kit may be used. This appliance is only for use with the type of gas indicated on the rating plate and may be installed in anaftermarket, permanently located, manufactured home (USA only) or mobile home, where not prohibited by localcodes. See owner’s manual for details. This appliance is not convertible for use with other gases, unless a certified kit is used. This vented gas fireplace heater is not for use with air filters. Keep burner and control compartment clean. See installation and operating instructions accompanyingappliance. This appliance must be properly connected to a venting system in accordance with the manufacturer’sinstallation instructions. Use only approved coaxial direct vent system to vent this appliance to the exterior. See owner’s manual for approved brands of venting. If the vent-air intake system is disconnected for servicing or any other reason, it must be resealed and / or reinstalled. WARNING: Improper installation, adjustment, alteration, service or maintenance can cause injury or property damage. Refer to the owner’s information manual provided with this appliance. For assistance or additional information consult a qualified installer, service agency or the gas supplier. VENTED GAS FIREPLACE HEATER - NOT FOR USE WITH SOLID FUEL Minimum Clearances to Combustibles Fireplace to Adjacent Wall Wood Floor Beneath Fireplace Back to Enclosure 3” (77mm) 0” (0mm) 0.125” (4mm) Base of Fireplace to Enclosure Top Sides to Enclosure Base of Fireplace to a Mantel 54” (1372mm) 0.625” (17mm) See Owner’s Manual FAN TYPE VENTED CIRCULATOR Blower Electrical Rating: 120V., 3.9 Amps, 60 Hz, 470 Watts Part No. 250-02898 / 250-02899 fan or blower assembly may be used.DANGER! Risk of Electric Shock. Disconnect power before servicing unit. Minimum Inlet Pressure (inches W.C.) Maximum Inlet Pressure (inches W.C.) Manifold Pressure on “HI” (inches W.C.) L.P. 11” 13” 11” N.G. 5.5” 7” 3.8” Input Rate on “HI” (BTU/Hr) Input Rate on “LO” (BTU/Hr) Orifice Size - (DMS) L.P. 33,000 17,555 #52 N.G. 33,000 18,331 #36 This appliance is equipped for use only at altitudes 0-2,000 feet (0-610m) in the USA. In Canada, 0-4,500 feet (0-1370m). For altitudes above 2,000 feet, the vent configuration, orifice, or combination of both may need to be changed. See owner’s manual for information on making these changes. 2015 2016 2014 Feb. Mar. Jan. May Jun. Apr. Aug. Sep. Jul. Nov. Dec. Oct.MANUFACTURE DATE: WARNING: Failure to install this appliance per the manufacturer’s instructions or failure to use only partsspecifically approved with this appliance may result in property damage or personal injury. 12521 Harbour Reach Drive Mukilteo, WA 98275 Manufactured by: www.travisproducts.com CAUTION: Do not operate this appliance with glass removed, cracked or broken. Replacement of the panel(s) should be doneby a licensed or qualified service person. 1083 10/31/14 Table of Contents 3 © Travis Industries 4140731 100-01372 Overview ................................................................... 2 Listing Details ........................................................... 2 Installation Options .................................................. 6 Heating Specifications ............................................. 6 Dimensions ............................................................... 6 Packing List .............................................................. 7 Additional Items Required ....................................... 7 Recommended Installation Procedure ................... 7 Massachusetts Requirements ................................ 8 Requirements for the Commonwealth of Massachusetts.................................................................8 MANUFACTURER REQUIREMENTS.............................8 Fireplace Placement Requirements ....................... 9 Clearances ......................................................................9 Raised Fireplaces ............................................................9 Televisions (or other electronics) Placed Near the Fireplace..........................................................................9 Televisions Placed Above the Fireplace ................ 10 Using a Mantel Between the Fireplace and Television ....10 Using a Recessed Fireplace Below a Television .............11 Using a Recessed Fireplace with a Recessed Television ........................................................................12 Minimum Framing Dimensions ............................... 13 Nailing Brackets – Extended (Tile Over) Install .... 14 Nailing Brackets – Flush Install .............................. 15 Corner Installations .................................................. 16 Removing the Front Panel ....................................... 17 Gas Line Requirements ........................................... 18 Fuel .................................................................................18 Gas Line Connection .......................................................18 Gas Inlet Pressure ...........................................................18 Directions for Connecting a Gas Pressure Test Gauge ...18 Gas Line Location ............................................................19 Relocating the Gas Line to the Baseplate ...................... 19 Electrical Connection ............................................... 20 Relocating the Electrical Line to the Baseplate .............. 20 Vent Requirements ................................................... 21 Vent Clearances ..............................................................21 Vent Firestop ...................................................................21 Altitude Considerations....................................................21 Approved Vent.................................................................21 Vent Installation ...............................................................21 Vertical Pipe Shield .........................................................22 Minimum Vent Pipe Shield – Used for Minimum Vent Configuration Only ...........................................................23 Minimum Vent Pipe Shield – Attaching the Side Shields.............................................................................24 Approved Vent Configurations ............................... 25 Restrictor Position ...........................................................25 Exhaust Restrictor ...........................................................25 Intake Restrictor ..............................................................26 Diffuser ............................................................................27 Minimum Vent Configuration: Horizontal Termination with 0”-18” Vertical Rise .................... 28 Vent Configuration: 4x6-5/8” Diameter Vent (Hor. Or Vert. Termination) ...................................... 29 Vent Configuration: 5x8” Diameter Vent (Hor. Or Vert. Termination) ................................................ 30 Termination Requirements ...................................... 31 Hearth Requirements ............................................... 32 Drywall Supports ...................................................... 32 Facing Requirements – Flush Install ...................... 33 Facing Requirements – Extended (Tile-Over) Install ......................................................................... 34 Do Not Drill or Screw Zone .............................................. 35 Mantel Requirements ............................................... 36 Mantel Column Clearances...........................................36 Steps for Finalizing the Installation ........................ 37 Air Shutter Adjustment .................................................... 38 Glass Frame Removal and Installation .................. 39 Fireback Installation ................................................. 41 Crushed Glass Installation ...................................... 43 LP Conversion Instructions .................................... 44 Wiring Diagram ......................................................... 48 Power Heat Duct Installation ................................... 49 10/31/14 4 Safety Precautions © Travis Industries 4140731 100-01372 Safety Warnings x Failure to follow all of the requirements may result in property damage, bodily injury, or even death. Young children should be carefully supervised when they are in the same room as the appliance. Toddlers, young children and others may be susceptible to accidental contact burns. A physical barrier is recommended if there are at risk individuals in the house. To restrict access to a fireplace or stove, install an adjustable safety gate to keep toddlers, young children and other at risk individuals out of the room and away from hot surfaces. Children and adults should be alerted to the hazards of high surface temperature and should stay away to avoid burns or clothing ignition. Do not touch the hot surfaces of the heater. Educate all children of the danger of a high-temperature heater. Due to the high temperature, the heater should be located out of traffic and away from furniture and draperies. x This unit must be installed by a qualified installer to prevent the possibility of an explosion. x This appliance must be installed in accordance with all local codes, if any; if not, in U.S.A. follow ANSI Z223.1 and NFPA 54(88), in Canada follow CSA B149.1. x A manufactured home (USA only) or mobile home OEM installation must conform with the Manufactured Home Construction and Safety Standard, Title 24 CFR, Part 3280, or, when such a standard is not applicable, the Standard for Manufactured Home Installations, ANSI/NCSBCS A225.1, or Standard for Gas Equipped Recreational Vehicles and Mobile Housing, CSA Z240.4. This appliance may be installed in Manufactured Housing only after the home is site located. x All exhaust gases must be vented outside the structure of the living-area. Combustion air is drawn from outside the living-area structure. The venting must not be connected to a chimney flue serving a separate solid-fuel burning appliance. x Notify your insurance company before hooking up this fireplace. x The instructions in this manual must be strictly adhered to. Do not use makeshift methods or compromise in the installation. Improper installation will void the warranty and safety listing. x This heater is approved for use with natural gas (NG) or propane (LP). Burning the incorrect fuel will void the warranty and safety listing and may cause an extreme safety hazard. Direct questions about the type of fuel used to your dealer. x Contact your local building officials to obtain a permit and information on any installation restrictions or inspection requirements in your area. x If the flame becomes sooty, dark orange in color, or extremely tall, do not operate the heater. Call your dealer and arrange for proper servicing. x It is imperative that control compartments, screens, or circulating air passageways of the heater be kept clean and free of obstructions. These areas provide the air necessary for safe operation. x Do not operate the heater if it is not operating properly in any fashion or if you are uncertain. Call your dealer for a full explanation of your heater and what to expect. x Do not store or use gasoline or other flammable liquids in the vicinity of this heater. x Do not operate if any portion of the heater was submerged in water or if any corrosion occurs. Immediately call a qualified service technician to inspect the appliance and to replace any part of the control system and any gas control which has been under water. 10/31/14 Safety Precautions 5 © Travis Industries 4140731 100-01372 Safety Warnings (continued) x Because this heater can be controlled by a thermostat there is a possibility of the heater turning on and igniting any items placed on or near the appliance. x Light the heater using the built-in igniter. Do not use matches or any other external device to light your heater. x Never remove, replace, modify or substitute any part of the heater unless instructions are given in this manual. All other work must be done by a trained technician. Don't modify or replace orifices. x The viewing glass should be opened only for conducting service. x Allow the heater to cool before carrying out any maintenance or cleaning. x Operate the heater according to the instructions included in this manual. x If the main burners do not start correctly turn the gas off and call your dealer for service. x This unit is not for use with solid fuel. x Do not place anything inside the firebox (except the optional artwork). x Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. x Do not throw this manual away. This manual has important operating and maintenance instructions that you will need at a later time. Always follow the instructions in this manual. x Instruct everyone in the house how to shut gas off to the appliance and at the gas main shutoff valve. The gas main shutoff valve is usually next to the gas meter or propane tank and requires a wrench to shut off. x A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. x If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. x Clothing or other flammable material should not be placed on or near the appliance. x Any safety screen, guard, or barrier removed for servicing an appliance must be replaced prior to operating the appliance. x Installation and repair should be done by a qualified service person. The appliance should be inspected before use and at least annually by a professional service person. More frequent cleaning might be required due to excessive lint from carpeting, bedding material, et cetera. It is imperative that control compartments, burners, and circulating air passageways of the appliance be kept clean. x Travis Industries, Inc. grants no warranty, implied or stated, for the installation or maintenance of your heater, and assumes no responsibility of any consequential damage(s). 10/31/14 6 Features and Specifications © Travis Industries 4140731 100-01372 Installation Options x Residential or Mobile Home x Straight or Corner Placement x Raised or Floor Placement x Internal or External Chase x Bedroom Approved Heating Specifications Natural Gas Propane Approximate Heating Capacity (in square feet)* Up to 1,700 Up to 1,700 Maximum BTU Input Per Hour 33,000 33,000 * Heating capacity will vary with floor plan, insulation, and outside temperature. Dimensions Left a' gauche Fro nt a v a nt Right droit Re ar arrie're 40-3/4" 1036mm 17" * 432mm * 54" 1372mm 37-3/8" 924mm 1" 25mm 1/2" 12mm * Includes the requisite clearance to framing (1/8" 4mm to rear, 5/8" 16mm to the sides) 10-3/8" 264mm 15-3/4" 401mm 11-1/4" 286mm 9-3/8" 239mm 34-3/4" 883mm 947mm 37-1/4" 210 lbs. 96 Kg. 10/31/14 Installation (for qualified installers only) 7 © Travis Industries 4140731 100-01372 Packing List x Propane Conversion Parts x Remote Control x 4 AA Batteries, 3 AAA Batteries x Glass Latch Tool x (2) Firestops (8” Diameter) x Minimum Vent Pipe Shield Additional Items Required x If using LP (propane) a conversion kit is required (sku 94400999 – GSR Stepper Motor Kit). x Gas Line Equipment (shutoff valve, pipe, etc.) x Electrical Equipment (min. 14 gauge, grounded line) x This Fireplace Requires Firebacks and 5 lbs. (2.2 Kg) of 1/4” Crushed Glass Firebacks 96100941 Stainless Steel 96100942 Black Enamel 96100943 Black Painted 96100944 Ledgestone Crushed Glass 94500580 Platinum (10 lbs.) 94500581 Bronze (10 lbs.) 94500582 Cobalt (10 lbs.) Recommended Installation Procedure x Frame the opening for the fireplace. Make sure to allow for vent installation. x This fireplace is designed to accommodate 1/2" (13mm) drywall (see "Nailing Brackets" on page 13 for details). Secure the fireplace to the framing. x Install the vent, gas line and electrical hook-up. x Install the drywall. x Install the hearth (if applicable). x Install the facing (if applicable). x Install the mantel (if applicable). x Finalize the installation (see page 36). 10/31/14 8 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Massachusetts Requirements NOTE: The following requirements reference various Massachusetts and national codes not contained in this document. Requirements for the Commonwealth of Massachusetts For all side wall horizontally vented gas fueled equipment installed in every dwelling, building or structure used in whole or in part for residential purposes, including those owned or operated by the Commonwealth and where the side wall exhaust vent termination is less than seven (7) feet above finished grade in the area of the venting, including but not limited to decks and porches, the following requirements shall be satisfied: Installation of Carbon Monoxide Detectors At the time of installation of the side wall horizontal vented gas fueled equipment, the installing plumber or gasfitter shall observe that a hard wired carbon monoxide detector with an alarm and battery back-up is installed on the floor level where the gas equipment is to be installed. In addition, the installing plumber or gasfitter shall observe that a battery operated or hard wired carbon monoxide detector with an alarm is installed on each additional level of the dwelling, building or structure served by the side wall horizontal vented gas fueled equipment. It shall be the responsibility of the property owner to secure the services of qualified licensed professionals for the installation of hard wired carbon monoxide detectors. In the event that the side wall horizontally vented gas fueled equipment is installed in a crawl space or an attic, the hard wired carbon monoxide detector with alarm and battery back-up may be installed on the next adjacent floor level. In the event that the requirements of this subdivision can not be met at the time of completion of installation, the owner shall have a period of thirty (30) days to comply with the above requirements; provided, however, that during said thirty (30) day period, a battery operated carbon monoxide detector with an alarm shall be installed. Approved Carbon Monoxide Detectors Each carbon monoxide detector as required in accordance with the above provisions shall comply with NFPA 720 and be ANSI/UL 2034 listed and IAS certified. Signage A metal or plastic identification plate shall be permanently mounted to the exterior of the building at a minimum height of eight (8) feet above grade directly in line with the exhaust vent terminal for the horizontally vented gas fueled heating appliance or equipment. The sign shall read, in print size no less than one-half (1/2) inch in size, “GAS VENT DIRECTLY BELOW. KEEP CLEAR OF ALL OBSTRUCTIONS”. Inspection The state or local gas inspector of the side wall horizontally vented gas fueled equipment shall not approve the installation unless, upon inspection, the inspector observes carbon monoxide detectors and signage installed in accordance with the provisions of 248 CMR 5.08(2)(a)1 through 4. Exemptions The following equipment is exempt from 248 CMR 5.08(2)(a)1 through 4: · The equipment listed in Chapter 10 entitled “Equipment Not Required To Be Vented” in the most current edition of NFPA 54 as adopted by the Board; and · Product Approved side wall horizontally vented gas fueled equipment installed in a room or structure separate from the dwelling, building or structure used in whole or in part for residential purposes. MANUFACTURER REQUIREMENTS Gas Equipment Venting System Provided When the manufacturer of Product Approved side wall horizontally vented gas equipment provides a venting system design or venting system components with the equipment, the instructions provided by the manufacturer for installation of the equipment and the venting system shall include: · Detailed instructions for the installation of the venting system design or the venting system components; and · A complete parts list for the venting system design or venting system. Gas Equipment Venting System NOT Provided When the manufacturer of a Product Approved side wall horizontally vented gas fueled equipment does not provide the parts for venting the flue gases, but identifies “special venting systems”, the following requirements shall be satisfied by the manufacturer: · The referenced “special venting system” instructions shall be included with the appliance or equipment installation instructions; and · The “special venting systems” shall be Product Approved by the Board, and the instructions for that system shall include a parts list and detailed installation instructions. A copy of all installation instructions for all Product Approved side wall horizontally vented gas fueled equipment, all venting instructions, all parts lists for venting instructions, and/or all venting design instructions shall remain with the appliance or equipment at the completion of the installation. See Gas Connection section for additional Commonwealth of Massachusetts requirements. 10/31/14 Installation (for qualified installers only) 9 © Travis Industries 4140731 100-01372 Fireplace Placement Requirements x Fireplace must be installed on a level surface capable of supporting the fireplace and vent x Fireplace must be placed directly on wood or non-combustible surface (not on linoleum or carpet) x Fireplace should be located out of traffic and away from furniture and draperies. x Fireplace must be placed so the gaps below and above the glass frame do not become blocked. x Fireplace may be placed in a bedroom. Please be aware of the large amount of heat this appliance produces when determining a location. Clearances (a) Clearance to Side of Fireplace 5/8” (16mm). Do not place insulation in this space. NOTE: Drywall or other combustible may contact the side of the fireplace in front of the framing. The material must not protrude in front of the fireplace and may be a maximum ½” (13mm) thick. (b) Clearance to Back of Fireplace 1/8” (4mm). Do not place insulation in this space. (c) When installed, walls in front of the fireplace must be a minimum 3” (77mm) to the side of the fireplace. Raised Fireplaces x The fireplace (and hearth, if desired) may be placed on a platform designed to support the fireplace and vent. x The base of the fireplace must be a minimum 54” below the room ceiling. The firebox opening is approximately 10.375” (264mm) above the base of the fireplace. For a typical raised fireplace of 36” (915mm), place the fireplace on a platform 25.625” (651mm) tall. a c b 10/31/14 10 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Televisions Placed Above the Fireplace The following section details three methods to allow for television installation above the fireplace. Using a Mantel Between the Fireplace and Television IMPORTANT NOTE REGARDING TELEVISIONS AND THIS FIREPLACE Most television manufacturers instruct the homeowner to not place the television above a heat source. Doing so may negatively affect the longevity of the television and may negate the warranty. If you do place a television above the fireplace, please be aware of the large amount of heat generated by the fireplace and consider placing the television above a mantel to reduce the amount of heat that reaches the television. The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Minimum Dimensions: (a) Mantel Height above Base of Fireplace Mantel must fall within shaded portion of the chart above. 42” (1067mm) with 8” (203mm) mantel depth See chart above if using a larger mantel. (b) Mantel Depth* Minimum 8” (203mm) * NOTE: The minimum mantel depth is 8”. This allows heat to travel forward and dissipate. EXAMPLES: If you have a TV that is greater than 6” deep (including the 1” gap behind), you will need to alter the mantel depth and height. If your TV is 9” deep (including the 1” gap behind), the mantel should be 11” (this provides the necessary 2” recess for the TV). The 11” mantel would require a 43.5” (292mm) mantel height (see chart above). WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring to protect from contact with hot surfaces. a Fireplace Min. 2" (51mm) From Front of TV Mantel Must be Min. 1" (26mm) Thick Min. 1" (26mm) Air Gap Behind TV (typically provided by wall mount) b Min. 1" (26mm) Television (TV) (b) Depth (a) Height Above Base of Fireplace 46" (1169mm) 0 " (0 mm ) 1" (2 5m m) 2 " (5 1m m ) 8" (2 0 3m m ) 7 " (17 8 m m) 6" (1 5 2m m ) 5 " (12 7 m m ) 4 " (1 0 2m m) 3 " (7 6m m ) 9" (2 29 m m ) 1 0 " (25 4m m) 1 1 " (2 7 9m m ) 1 2" (3 05 mm ) 45" (1143mm) 44" (1118mm) 43" (1093mm) 42" (1067mm) 41" (1042mm) 47" (1194mm) 10/31/14 Installation (for qualified installers only) 11 © Travis Industries 4140731 100-01372 Using a Recessed Fireplace Below a Television IMPORTANT NOTE REGARDING TELEVISIONS AND THIS FIREPLACE Most television manufacturers instruct the homeowner to not place the television above a heat source. Doing so may negatively affect the longevity of the television and may negate the warranty. If you do place a television above the fireplace, please be aware of the large amount of heat generated by the fireplace and consider placing the television above a mantel to reduce the amount of heat that reaches the television. The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Minimum Dimensions: (a) Fireplace Recess Height above Base of Fireplace Recess must fall within shaded portion of the chart above. 42” (1067mm) with 8” (203mm) recess depth See chart above if using a larger recess. (b) Fireplace Recess Depth plus Mantel Depth* Minimum 8” (203mm) (c) Fireplace Recess Width 45.5” (1156mm) * NOTE: The minimum recess plus mantel depth is 8”. This allows heat to travel forward and dissipate. EXAMPLES: If you have a TV that is 3” deep (including the 1” gap behind), you will need to put in a 5” mantel (the 2” is measured from the front of the TV). The fireplace can then be recessed 3” into the wall to allow for the 8” of recess plus mantel depth. WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring to protect from contact with hot surfaces. b Fireplace Min. 1" (26mm) Air Gap Behind TV (typically provided by wall mount) Television (TV) Min. 6" (152mm) a Min. 2" (51mm) From Front of TV Min. 1" (26mm) c Min. 6" (152mm) (b) Depth (a) Height Above Base of Fireplace 46" (1169mm) 0 " (0 m m) 1 " (25 mm) 2" (5 1mm ) 8 " (2 03 mm ) 7 " (1 78 mm) 6 " (1 52 mm ) 5 " (1 27 mm ) 4 " (1 0 2mm ) 3" (7 6mm ) 9" (22 9m m ) 10 " (25 4mm ) 11 " (2 7 9mm ) 1 2" (3 05 m m) 45" (1143mm) 44" (1118mm) 43" (1093mm) 42" (1067mm) 41" (1042mm) 47" (1194mm) 10/31/14 12 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Using a Recessed Fireplace with a Recessed Television IMPORTANT NOTE REGARDING TELEVISIONS AND THIS FIREPLACE Most television manufacturers instruct the homeowner to not place the television above a heat source. Doing so may negatively affect the longevity of the television and may negate the warranty. If you do place a television above the fireplace, please be aware of the large amount of heat generated by the fireplace and consider placing the television above a mantel to reduce the amount of heat that reaches the television. The homeowner must understand that Travis Industries does not take responsibility for any negative impact to televisions placed near this fireplace. Minimum Dimensions: (a) Fireplace Recess Height above Base of Fireplace Recess must fall within shaded portion of the chart above. 42” (1067mm) with 8” (203mm) recess depth See chart above if using a larger recess. (b) Fireplace/TV Recess Depth* Minimum 8” (203mm) (c) Fireplace Recess Width 45.5” (1156mm) * NOTE: The minimum recess depth is 8”. This allows heat to travel forward and dissipate. EXAMPLES: If you have a TV that is greater than 6” deep (including the 1” gap behind), you will need to alter the fireplace recess depth and height. If your TV is 9” deep (including the 1” gap behind), the recess should be 11” (this provides the necessary 2” recess for the TV). The 11” recess would require a 43.5” (292mm) fireplace recess height (see chart above). If you have a TV that is 3” deep (including the 1” gap behind), you will need to put in a 5” mantel (the 2” is measured from the front of the TV). The fireplace can then be recessed 3” into the wall to allow for the 8” of recess plus mantel depth. WIRING NOTE: If running wiring into the enclosure, use thermal insulating wrap around the wiring. Secure the wiring to protect from contact with hot surfaces. b a Fireplace NOTE: These two walls are at the same depth. Min. 1" (26mm) Air Gap Behind TV (typically provided by wall mount) Television (TV) Min. 3" (77mm) Min. 6" (152mm) Min. 2" (51mm) From Front of TV c b (b) Depth (a) Height Above Base of Fireplace 46" (1169mm) 0 " (0mm ) 1" (25 m m) 2" (51 mm) 8" (20 3m m ) 7" (17 8m m ) 6 " (1 52 m m) 5 " (12 7mm ) 4" (10 2m m ) 3" (76 m m) 9" (22 9m m ) 10 " (2 54 mm) 11 " (2 79 mm) 12 " (3 05 mm) 45" (1143mm) 44" (1118mm) 43" (1093mm) 42" (1067mm) 41" (1042mm) 47" (1194mm) 10/31/14 Installation (for qualified installers only) 13 © Travis Industries 4140731 100-01372 Minimum Framing Dimensions The fireplace enclosure must be a minimum 54” 1372mm tall (do not build into the fireplace enclosure) 40-3/4" 1036mm 17" 432mm Flush Install 16-1/2" 420mm Extended (Tile Over) Install 54" 1372mm 54" 1372mm a a 10/31/14 14 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Nailing Brackets – Extended (Tile Over) Install The fireplace has nailing brackets on both sides. Secure the fireplace to the framing. NOTE: Make sure the fireplace is square and plumb when placed in the framing. Measured corner-to-corner the fireplace should be square. Use shims to insure the fireplace is square. Bend the three nailing brackets out (each side) NOTE: if you can not use the front nailing brackets, an additional bracket is supplied on the side that allows the fireplace to be secured to the floor (bend tab down and secure). Secure the fireplace to the framing using the nailing brackets Nailing Bracket This 5/8" (16mm) tab acts as a standoff and helps center the fireplace in the framing) 10/31/14 Installation (for qualified installers only) 15 © Travis Industries 4140731 100-01372 Nailing Brackets – Flush Install The fireplace has nailing brackets on both sides. Secure the fireplace to the framing. NOTE: Make sure the fireplace is square and plumb when placed in the framing. Measured corner-to-corner the fireplace should be square. Use shims to insure the fireplace is square. Bend the side nailing brackets as shown below. NOTE: if you can not use the front nailing brackets, an additional bracket is supplied on the side that allows the fireplace to be secured to the floor (bend tab down and secure). Secure the fireplace to the framing using the nailing brackets and vertical drywall support. Bend the vertical drywall support forward. The mounting hole is now vertical and may be secured to the framing from below. Bend the top nailing bracket as shown until it is flush with the front of the fireplace. c a b Rotate the bracket on the rivet 180 degrees. 10/31/14 16 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Corner Installations A typical 45° installation uses the framing dimensions shown in the illustration below (NOTE: all clearances still apply). 52-1/8" Min. 1324mm Minimum 5/8" (16mm) Clearance Typically 19-1/2" 496mm 10/31/14 Installation (for qualified installers only) 17 © Travis Industries 4140731 100-01372 Removing the Front Panel The front cover may be removed to access the components. This is required when relocating the electrical or gas inlet location. To remove the front cover (a) Remove the center nut. (b) Loosen the two outer nuts. (c) Rotate the front panel down. (d) Remove the front cover. 11/32" Wrench 10/31/14 18 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Gas Line Requirements MASSACHUSETTS INSTALLATIONS - WARNING: THIS PRODUCT MUST BE INSTALLED BY A LICENSED PLUMBER OR GAS FITTER WHEN INSTALLED WITHIN THE COMMONWEALTH OF MASSACHUSETTS. OTHER MASSACHUSETTS CODE REQUIREMENTS: x Flexible connector must not be longer than 36 inches. x Shutoff valve must be a “T” handle gas cock. x Only direct vent sealed combustion products are approved for bedrooms or bathrooms. x Fireplace dampers must be removed or welded in the open position prior to the installation of a fireplace insert or gas log. x A carbon monoxide (CO) detector is required in the same room as the appliance. x The gas line must be installed in accordance with all local codes, if any; if not, follow ANSI 223.1 and NFPA 54(88), in Canada follow CSA B149.1 and the requirements listed below. x The fireplace and gas control valve must be disconnected from the gas supply piping during any pressure testing of that system at test pressures in excess of 1/2 psig (3.5 kPA). For pressures under 1/2 psig (3.5 kPA), isolate the gas supply piping by closing the manual shutoff valve. x Leak test all gas line joints and the gas control valve prior to and after starting the fireplace. x This unit has been listed using the included internal gas shutoff valve. Fuel x This fireplace is designed either for natural gas or for propane (but not for both). Gas Line Connection x Installation must be performed by a qualified installer, service agency or the gas supplier (In Massachusetts a licensed plumber/gasfitter). Gas Inlet Pressure Maximum Input Pressure Minimum Input Pressure Natural Gas 7" W.C. (1.74 kPA) 5.5” W.C. (1.37 kPA) Propane 13" W.C. (3.23 kPA) 11” W.C. (2.74 kPA) x If the pressure is not sufficient, make sure the piping used is large enough, the supply regulator is adequately adjusted, and the total gas load for the residence does not exceed the amount supplied. x The supply regulator (the regulator that attaches directly to the residence inlet or to the propane tank) should supply gas at the input pressure listed above. Contact the local gas supplier if the regulator is at an improper pressure. Directions for Connecting a Gas Pressure Test Gauge The gas control valve (shown to the left) has two accessible ports for testing line pressure and output pressure. Loosen the brass screw on either test port and place a 5/16” i.d. rubber or plastic tubing over the tapered test port. Connect the tubing to the test gauge. WARNING: The brass screw must be tightened after testing to prevent gas leakage. Input pressure Output pressure 10/31/14 Installation (for qualified installers only) 19 © Travis Industries 4140731 100-01372 Gas Line Location Gas line may be plumbed from the left side (stock) or below. See illustration and table below to determine gas line location. a b Left Side Gas Line Location (Stock) 4” (102mm) 3.25” (83mm) Baseplate Gas Line Location 6.25” (159mm) 12” (305mm) Relocating the Gas Line to the Baseplate Remove the front panel (see page 17). Disconnect the gas inlet (shutoff valve) from the left side (keep the 4 screws). Re- route the gas line to the baseplate and connect the gas inlet to the opening on the base using the 4 screws. Leak-test the gas line to verify all connections are tight. Remove the plastic plug from the base and insert it into the hole on the left side. Left Side Gas Line Location Baseplate Gas Line Location Framing Opening a b a b 10/31/14 20 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Electrical Connection x The electrical line to the grounded receptacle inside the fireplace must be installed by a qualified installer and must meet all local codes. x Make sure the household breaker is shut off prior to working on any electrical lines. x The appliance, when installed, must be electrically grounded in accordance with local codes or, in the absence of local codes, with the National Electrical Code, ANSI/NFPA 70, or the Canadian Electrical Code, CSA C22.1. x The electrical line must be a min. 14 gauge, and supply 120 Volts, 60 Hz, and 5.7 Amps. x Route the electrical connection through the junction box cover plate and attach to the hookup wires pictured below. Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation. Do not connect 110-120 VAC to the gas control valve or wiring system of this fireplace. a b Left Side Electrical Location (Stock) 7” (178mm) 3.5” (89mm) Baseplate Electrical Location 7.75” (197mm) 25.5” (648mm) Relocating the Electrical Line to the Baseplate Remove the front panel (see page 17). Remove the junction box from the left side (keep the screws). Remove the cover plate from the baseplate (keep the screws). Attach the junction box to the baseplate (make sure all wiring is kept from contacting hot or moving components). Attach the cover plate to the left side. Junction Box Junction Box (from inside fireplace) Baseplate Cover Plate a b c d Framing Opening a b a b 10/31/14 Installation (for qualified installers only) 21 © Travis Industries 4140731 100-01372 Vent Requirements x The gas appliance and vent system must be vented directly to the outside of the building, and never be attached to a chimney serving a separate solid fuel or gas-burning appliance. Each direct vent gas appliance must use its own separate vent system. x In addition to the requirements listed here, follow the requirements provided with the vent. Vent Clearances x The vent must maintain the required clearance to combustible materials to prevent a fire. Do not fill air spaces with insulation. Minimum Vent Configurations (elbow directly off fireplace - see page 28) Minimum Clearance Above Vent 4" (104mm) Minimum Clearance to Sides & Below Vent 1" (25mm) NOTE: Make sure to use the included firestops with this configuration. All Other Vent Configurations Minimum Clearance to Vent 1" (25mm) Vent Firestop x A firestop is required whenever the vent penetrates a wall, floor, or ceiling (passes through framing members). Altitude Considerations x This heater has been tested at altitudes ranging from sea level to 6,000 feet (1800 M). In this testing we have found that the heater, with its standard orifice, burns correctly with just an air shutter adjustment. x Failure to adjust the air shutter properly may lead to improper combustion which can create a safety hazard. Consult your dealer or installer if you suspect an improperly adjusted air shutter. Approved Vent x Always use the high-wind cap. The high-wind sconce cap is not allowed. x Installation instructions for Simpson Dura-Vent may be found at www.duravent.com. Minimum Vent Configurations (see page 28) Use 8" diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)*. All Other Vent Configurations Use 8" or 6-5/8” diameter Simpson Dura-Vent Model Direct-Vent Pro (or GS)* (see vent configuration for details). * Other vent may be approved with this fireplace. Check with the vent manufacturer for details). Vent Installation x Slide the vent sections together and turn 1/4 turn until the sections lock in place. x Screws are not required to secure the vent. However, three screws may be used to secure vent sections together if desired. x High temperature sealant is recommended at the appliance starter section connection (use high-temperature silicone or Mill-Pac®). x If disassembly is required, at time of re-assembly check to see if the vent creates a tight fit. If it does not, apply high temperature sealant to the joints of the affected sections. x Horizontal sections require a 1/4" (6mm) rise every 12" (305mm) of travel. x Horizontal sections require non-combustible support every three feet (e.g.: plumbing strap). 10/31/14 22 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Vertical Pipe Shield The vertical pipe shield must be bent to a vertical position after the fireplace is in position. 10/31/14 Installation (for qualified installers only) 23 © Travis Industries 4140731 100-01372 Minimum Vent Pipe Shield – Used for Minimum Vent Configuration Only The minimum vent pipe shield and side shields are required when running minimum vent configurations (see page 28). The shield is shipped with the fireplace loose and must be installed as shown below. Secure the pipe shield to the firestop (mouting holes are slotted to allow for leveling). Approximately 41" (1042mm) with no rise. Pipe Shield Firestop Secure the pipe shield to the pipe with 4 screws. Make sure shield is level and maintains 1" (25mm) clearance to pipe. 1" (25mm) Clearance 10/31/14 24 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Minimum Vent Pipe Shield – Attaching the Side Shields Side Shields Attach the side shields to the pipe shield as shown below Side View Back View Secure both side shields to the pipe shield with 4 screws. 10/31/14 Installation (for qualified installers only) 25 © Travis Industries 4140731 100-01372 Approved Vent Configurations Restrictor Position x Intake and exhaust restrictors are built into the appliance to adjust the flow rate of intake air and exhaust gases. Depending upon the vent configuration, you may be required to adjust the restrictor positions. The charts for vent configurations detail the correct vent restrictor positions. Exhaust Restrictor NOTE: Certain vent configurations call for exhaust restrictor removal (position # 0). If this is the case, remove the exhaust restrictor and replace the attachment screws in the firebox ceiling. Loosen these 2 screws on the exhaust restrictor. Slide the restrictor to the correct restrictor position (see the illustration below). Screw location indicates restrictor position. In this example, the restrictor is set in position # 4. Tighten the screws to secure the restrictor. # 6 # 5 # 4 # 3 # 2 (open - stock position) # 1 Back of Firebox Back Wall of Firebox Firebox Roof 10/31/14 26 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Intake Restrictor The intake restrictor is accessed by removing the burner (see LP Conversion Instructions on page 44 for details). The intake restrictor is shipped in the open position (position # 1). Follow the directions below to change the intake restrictor to position # 2 or # 3. Position # 1 (stock - open) Position # 2 Loosen the three screws shown to the right (1/4” nutdriver). Then slide the restrictor down and re- tighten the screws. The intake restrictor is located behind the burner, on the rear wall of the firebox. Position # 3 Follow the directions above for position # 2. Then loosen the four nuts shown to the right (11/32” nutdriver). Then slide the restrictor extension down and re-tighten the nuts. 10/31/14 Installation (for qualified installers only) 27 © Travis Industries 4140731 100-01372 Diffuser The diffuser is located inside the inner flue assembly (accessed by removing the exhaust restrictor). Remove the diffuser. 1/4" Nutdriver Secure the flattened diffuser plate with the screws removed earlier. Bend the round portion of the diffuser so it is flat (open). Before (Closed - Stock) After (Open) DIFFUSER SIDE VIEW 10/31/14 28 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Minimum Vent Configuration: Horizontal Termination with 0”-18” Vertical Rise x Use 5x8” Diameter Coaxial Vent x NOTE: Use the included minimum vent pipe shield (and side shields – see page 23). x NOTE: Use both included 8” firestops (use on front and back of wall penetration). x The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. x One 45° elbow may be used on the horizontal run. x A maximum of 18” of vertical vent may be placed on top of the fireplace. The fireplace enclosure may need to be raised to accommodate the added rise. The pipe shield may be cut down if it interferes with framing. x HINT: Use minimum vent kit “H” (96200332) from Travis Industries (additional vent may be required). Exhaust Restrictor # 1 (stock) Diffuser Closed (stock) Intake Restrictor # 1 (stock) 3 feet (0.915m) 0 feet 0 feet Min. 3.9" (100mm) Horizontal Section Max. 14' (4.2M) Horizontal Section(s) 5 feet (1.5 m) 10 feet (3 m) 14' max (4.2 m) Min. 0" (0mm) Vertical Sections Max. 18"' (0.5M) Vertical Sections 5 feet (1.5 m) 10/31/14 Installation (for qualified installers only) 29 © Travis Industries 4140731 100-01372 Vent Configuration: 4x6-5/8” Diameter Vent (Hor. Or Vert. Termination) x Use 4x6-5/8” Diameter Coaxial Vent. Connect a 8” to 6-5/8” reducer directly to the fireplace (sku 98900165). x NOTE: The included pipe shield is not required and may be discarded. The included firestops may be discarded. x The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. x Up to five elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet 5 feet (1.5m) 0 feet 20 feet (6m) 20 feet (6m) 5 feet (1.5m) 10 feet (3m) 5 feet (1.5m) 10 feet (3m) 0 feet 15 feet (4.5m) 20 feet (6m) 10 feet (3m) 15 feet (4.5m) 15 feet (4.5m) 20' (6m) max 10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40 feet (12m) 45 feet (13.5m) 50 feet (15m) 55 feet (16.5m) 60 feet (18m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40 feet (12m) 45 feet (13.5m) 50 feet (15m) 55 feet (16.5m) 60 feet (18m) max Attach reducer directly to the fireplace. Intake Restrictor # 2 Exhaust Restrictor # 3 Diffuser Open Intake Restrictor # 2 Exhaust Restrictor # 4 Diffuser Open Intake Restrictor # 3 Exhaust Restrictor # 6 Diffuser Open This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 10/31/14 30 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Vent Configuration: 5x8” Diameter Vent (Hor. Or Vert. Termination) x Use 5x8” diameter vent. x NOTE: The included pipe shield is not required and may be discarded. The included firestops may be discarded. x The termination must fall within the shaded area shown in the chart. Use the indicated restrictor positions. NOTE: Vertical Terminations Require a minimum 10’ rise. x Up to 3 elbows (45° or 90°) may be used. Only one horizontal elbow may be used. 5 feet (1.5m) 0 feet 0 feet 5 feet (1.5m) 0 feet 20 feet (6m) 20 feet (6m) 5 feet (1.5m) 10 feet (3m) 5 feet (1.5m) 10 feet (3m) 0 feet 15 feet (4.5m) 20 feet (6m) 10 feet (3m) 15 feet (4.5m) 15 feet (4.5m) 20' (6m) max 10 feet (3m) 15 feet (4.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40' (12m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40 feet (12m) 45 feet (13.5m) 50 feet (15m) 55 feet (16.5m) 60 feet (18m) max 25 feet (7.5m) 30 feet (9m) 35 feet (10.5m) 40 feet (12m) 45 feet (13.5m) 50 feet (15m) 55 feet (16.5m) 60 feet (18m) max Minimum 2' rise (Hor. Term.) Intake Restrictor # 1 Exhaust Restrictor # 1 Diffuser Closed Intake Restrictor # 2 Exhaust Restrictor # 3 Diffuser Open Intake Restrictor # 3 Exhaust Restrictor # 6 Diffuser Open Minimum 10' rise (Vert. Term.) This is considered a horizontal elbow (it does not matter whether it turns right or left). It may be a 90° or 45° elbow. This is considered a vertical elbow Horizontal length is calculated by adding both lengths of horizontal run (Horizontal Length = H1 + H2). H1 H2 10/31/14 Installation (for qualified installers only) 31 © Travis Industries 4140731 100-01372 Termination Requirements ! Venting terminals shall not be recessed into a wall or siding. A Minimum 9" (229mm) clearance from any door or window B Minimum 12" (305mm) above any grade, veranda, porch, deck or balcony C Minimum 1" (25mm) from outside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. D Minimum 1" (25mm) from inside corner walls NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. E Minimum 11" (279mm) clearance below unventilated soffits or roof surfaces Minimum 18" (457mm) clearance below ventilated soffits Minimum 6" (152mm) clearance below roof eaves NOTE: Vinyl surfaces require 24" (610mm) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. F Minimum 12" (305mm) clearance below a veranda, porch, deck or balcony NOTE: Permitted only if veranda, porch, deck, or balcony is fully open on a minumum of two sides beneath the floor. NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. G Minimum 48" (1219mm) clearance from any adjacent building H Minimum 84" (2134mm) clearance above any grade when adjacent to public walkways or driveways NOTE: may not be used over a walkway or driveway shared by an adjacent building I Minimum 9" (229mm) clearance to any nonmechanical air supply inlet to the building or the combustion air inlet to any other appliance. J Minimum 36" (914mm) clearance above any mechanical air supply inlet if within 10’ (3M) horizontally K Minimum 36" (914mm) from the area above the meter/regulator (vent outlet) - this extends 15’ (4.5M) above the regulator NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. L Minimum 36" (914mm) from the meter/regulator (vent outlet) NOTE: Clearance in accordance with local installation codes and the requirements of the gas supplier. M Minimum 12” (305mm) above the roof line (for vertical terminations) N Minimum 24” (610mm) horizontal clearance to any surface (such as an exterior wall) – for vertical terminations 11" Min. (279mm) 6" Min. (152mm) Roof Surface Roof Eaves C B H E G A D F L K J I NOTE: Measure clearances to the nearest edge of the exhaust hood. A E E M N 10/31/14 32 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Hearth Requirements x If installed near carpet or other combustible flooring, the fireplace must be raised so the base of the unit is above the carpet surface or flooring material. WARNING: A non-combustible hearth is not required. However, if the heater is installed next to the floor, we recommend a hearth to protect the flooring surface from discoloration or other negative impact from the heater. Drywall Supports Attach the drywall supports as shown below. (A) (B) 10/31/14 Installation (for qualified installers only) 33 © Travis Industries 4140731 100-01372 Facing Requirements – Flush Install x The included fiber board is required and must remain attached to the fireplace (see “a” below). x Drywall (or other combustible) may be placed above the fiber board (see “b” below). Secure the drywall to the vertical drywall supports. Do not place drywall over the front of the fireplace. x Marble, tileboard or other non-combustible facing may be placed along the front of the fireplace around the perimeter of the glass opening (see “c” below). Do not install facing over the ledge to the glass opening. x Drywall (or other combustible may butt up against the non-combustible facing. WARNING: Do not use adhesive to secure the facing. The high temperatures of the fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non- combustible, non-odorous adherent) to attach the facing. NOTE: Screws may be used to secure cement board or tile backer to the fireplace. Do not penetrate the fireplace more than 1/2” (13mm). Install a sheet of drywall (b) to the vertical drywall supports (this acts as a spacer for the non- combustible facing). Do not drill or screw zone (see page 35) (a) Fiber Board (included with fireplace) (b) Drywall (or other combustible) (c) Marble, tileboard or other non- combustible Ad h esiv e a b c 37-1/4" 947mm 10-3/8" 264mm 15-3/4" 401mm Base of Fireplace b 10/31/14 34 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Facing Requirements – Extended (Tile-Over) Install x The included fiber board is required and must remain attached to the fireplace (see “a” below). x Drywall (or other combustible) may be placed above the fiber board (see “b” below) and to the sides and below the face of the fireplace. x Tile or other non-combustible facing may be placed along the front of the fireplace around the perimeter of the glass opening (see “c” below). Typical installations use 12” (305mm) or greater of non-combustible facing around the perimeter of the glass opening. Do not install facing over the ledge to the glass opening. WARNING: Do not use adhesive to secure the facing. The high temperatures of the fireplace may cause adhesives to emit odors. Use mastic or thin set (or other non- combustible, non-odorous adherent) to attach the facing. NOTE: Screws may be used to secure cement board or tile backer to the fireplace. Do not penetrate the fireplace more than 1/2” (13mm). (a) Fiber Board (included with fireplace) (b) Drywall (or other combustible) (c) Tile (or other non- combustible)Adh esive a b 10-3/8" 264mm 15-3/4" 401mm 11-1/4" 286mm c 37-1/4" 947mm 10/31/14 Installation (for qualified installers only) 35 © Travis Industries 4140731 100-01372 Do Not Drill or Screw Zone When using screws to secure tile-board or other non-combustible to the front of the fireplace, make sure to avoid the area shown below. Make sure screws penetrate no more than ½” (13mm) into the fireplace. Do not drill screws into this shaded area. Fireplace components are located in this area. Maximum Screw Penetration = 1/2" (long screws will hinder component access) 10/31/14 36 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Mantel Requirements x If installing a TV above a mantel, see the section “Televisions Placed Above the Fireplace” on page 10. x Use the table below to determine the maximum mantel depth allowed. The mantel depth (measured from the non-combustible facing) must fall within the shaded portion of the table. x Any material above the fireplace that protrudes more than 3/4” (19mm) from the non-combustible facing is considered a mantel and must meet the mantel requirements. Mantel Column Clearances x Combustible mantel columns (legs) that protrude more than ¾” (19mm) from the front of the fireplace require a 3” (77mm) clearance to the side of the fireplace. x Combustible mantel columns (legs) that protrude ¾” (19mm) or less from the glass frame must meet the facing clearances (minimum 0” (0mm) from the side of the fireplace). x Non-combustible mantel columns do not have a minimum clearance. Maximum Mantel Depth (b) Mantel Height Above Base (a) 46" (1169mm) 0 " (0m m ) 1" (25 m m) 2 " (5 1 mm ) 8 " (2 0 3 mm ) 7 " (1 7 8m m ) 6 " (1 52 m m) 5" (1 2 7 mm ) 4 " (1 0 2 m m ) 3 " (7 6m m ) 9 " (2 2 9 m m ) 1 0" (2 5 4 m m ) 1 1 " (2 7 9m m ) 1 2 " (30 5 m m ) 45" (1143mm) 44" (1118mm) 43" (1093mm) 42" (1067mm) 41" (1042mm) 40" (1016mm) 47" (1194mm) 39" (991mm) 37 (940mm) 38" (966mm) a b 10/31/14 Installation (for qualified installers only) 37 © Travis Industries 4140731 100-01372 Steps for Finalizing the Installation 1. Remove the glass frame (see page 39). NOTE: If using propane (LP) convert the appliance prior to installing the logs. 2. We recommend you purge the gas line at this time (with the glass frame removed). This allows gas to be detected once it enters the firebox, ensuring gas does not build up. 3. Install the required firebacks (see page 41). 4. Remove the heat shield from the battery box (remove and discard the lock-tie – see illustration below). Install the four AA batteries into the battery box (NOTE: the heat shield must be in place whenever the fireplace is in operation). The AA batteries act as a power backup in case the household (AC) power goes out and are required for operation. Install three AAA batteries into the remote (see illustration below). Synchronize the transmitter to the IFC (see the owner’s manual). 5. Make sure the accent light bulbs are in place and work correctly. NOTE: Take care to not touch the bulb with your fingers (use a cloth or paper towel). 6. Install the crushed glass (see page 43). 7. Replace the glass frame. Heat Shield FUSE FUSE Lock-Tie Battery Box AAA Battery AAA Battery °F AAA Battery AA Battery AA Battery AA Battery AA Battery 10/31/14 38 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 8. Start the heater. 9. Leak test all gas joints. 10. Check the air shutter following the directions below. Air Shutter Adjustment Let the heater burn for fifteen minutes (make sure the logs and glass are in place). The flames should be yellow with no sooting. Adjust the air shutter, if necessary, to achieve the correct looking flame. Air Shutter Adjustmen 11. Adjust the flame to its highest position - the flames should not contact the top of the firebox. Check the flame on low position. The flames should burn off of each burner hole. If the heater does not work correctly, contact your Travis dealer for a remedy. 12. Give this manual to the home owner for future reference and fully explain operation of this heater. For comprehensive operating and maintenance instructions, refer to the Owner's Manual (part # 100-01253). ACID WASH WARNING: Make sure any masonry that has been treated with acid wash has been properly neutralized (this is used primarily with brick faces). Acid wash (muriatic acid) is used to remove excess mortar. Burner Air Shutter Control Right = More Air Left = Less Air NOTE: Use pliers to adjust the air shutter (it will be hot). Typically, the air shutter is more closed (right) on NG, more open (left) on LP. Correct Flames should be blue at the base, yellow-orange on the top. If the flames are too tall or sooty on the ends, open the air shutter. Not Enough Air If the flames are all blue and short, close the air shutter. Too Much Air 10/31/14 Installation (for qualified installers only) 39 © Travis Industries 4140731 100-01372 Glass Frame Removal and Installation A barrier designed to reduce the risk of burns from the hot viewing glass is provided with this appliance and shall be installed for the protection of children and other at-risk individuals. If the barrier becomes damaged, the barrier shall be replaced with the manufacturer’s barrier for this appliance. Do not remove the glass frame with the screen attached – it will not disengage correctly and may damage the screen. The appliance must be completely cool before removing the glass. Do not strike or slam the glass. Warning: Do not operate appliance with the glass front removed, cracked or broken. Replacement of the glass should be done by a licensed or qualified service person. GLASS FRAME TOOL The glass frame tool is shipped inside the fireplace, under the concealment cover. The first time it is used you may need to loosen the screw (1/4” wrench). The tool is accessed after removing the screen. NOTE: Replace the tool in this location after use. 1. Remove the concealment cover and place aside. It has two finger holes that aid in removal. 10/31/14 40 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 2. Remove the three screws holding the screen in place (1/4” nutdriver- magnetic driver recommended). Then pivot the screen down slightly until the clips on the bottom disengage from the glass frame. 3. Use the glass tool to unlatch the glass frame. Remove the glass frame. The glass frame is held in place with four tabs inserted into four slots at the bottom of the firebox opening. 10/31/14 Installation (for qualified installers only) 41 © Travis Industries 4140731 100-01372 Fireback Installation Fireplace must not be operated without the firebacks in place. The directions below show installation of metal firebacks. If using ceramic firebacks, follow the directions included with the firebacks (the rear fireback clips are removed and discarded). 1 Access the firebox. 2 Remove the two rear fireback clips from the firebox ceiling (1/4” nutdriver). The clips are located along the upper rear edge of the firebox. 3 Install the rear fireback. Hold the fireback at an angle while installing to allow it to pass through the firebox opening. 4 Replace the rear fireback clips to secure the rear fireback in place. The fireback clip has a keyhole slot. It can be removed by loosening the screw and sliding the clip out. 10/31/14 42 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 5 Remove the two side fireback clips from the firebox ceiling (1/4” nutdriver). They are located at the outward edges of the firebox near the glass opening. 6 Install the right side fireback. Place the fireback in position and replace the fireback clip to secure the right fireback in place. 7 Install the left fireback (see step # 6). The side fireback clip has a keyhole slot. It can be removed by loosening the screw and sliding the clip out. 10/31/14 Installation (for qualified installers only) 43 © Travis Industries 4140731 100-01372 Crushed Glass Installation Do not allow the crushed glass to block the air slots or to become too thick (maximum 1 layer deep on the burner). Failure to properly install glass may lead to sooting and improper burning. If converting to LP (propane), convert the appliance prior to placing the crushed glass. Install the crushed glass on the glass tray following the directions below. Quantity of Crushed Glass No Logs (stock) Driftwood Log Set (NOTE: Install logs first) 5 lbs. (2.2 Kg) 4.5 lbs. (2 Kg) Before installing the crushed glass, make sure the pilot guard is in place (it is zip-tied to the glass tray – remove and discard the zip-tie). After installing the glass, remove the pilot guard. Make sure no glass covers the pilot opening. Disperse the crushed glass evenly along the glass tray. Make sure the two air channels are free of crushed glass. Use the glass frame tool (or screwdriver) to clear this area. Make sure the glass is only 1 layer deep on the burner. Pilot Guard 10/31/14 44 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 LP Conversion Instructions WARNING This conversion kit shall be installed by a qualified service agency in accordance with the manufacturer’s instructions and all applicable codes and requirements of the authority having jurisdiction. If the information in these instructions is not followed exactly, a fire, explosion or production of carbon monoxide may result causing property damage, personal injury or loss of life. The qualified service agency is responsible for the proper installation of this kit. The installation is not proper and complete until the operation of the converted appliance is checked as specified in the manufacturer’s instructions supplied with the kit. The GSR Stepper Motor Kit (SKU 94400999) is required for converting this appliance to LP. The kit contains the stepper motor (regulator), torx wrench, and pilot orifice. The burner orifices and burner gaskets are shipped with the appliance. 1. Access the firebox. 2. Remove the glass tray. Remove the 6 screws holding it in place (1/4” nutdriver). 10/31/14 Installation (for qualified installers only) 45 © Travis Industries 4140731 100-01372 3. Remove the burner. It is held in place with 6 screws (1/4” nutdriver). 4. Remove the burner support as shown below. It is held in place with 10 screws (1/4” nutdriver). 5. Remove and discard the NG (stock) manifold cover and orifice gasket (1/4” nutdriver). Install the LP manifold cover included in the owner’s pack. LP Manifold Cover 10/31/14 46 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 6. Follow the directions below to replace the orifice. 7. Install the LP pilot orifice following the instructions below. (a) Use a 7/16” open-end wrench to remove the pilot hood. (b) Remove and discard the Natural Gas (NG) orifice. Place the LP orifice in the pilot assembly then replace the pilot hood, tightening the pilot hood until it is snug (do not over-tighten). 1/2" Wrench Use a 9/16" wrench to secure the manifold while removing the orifice with a 1/2" wrench. Screw the LP orifice until orifice protrudes 15/16" (23.8mm) indicating full insertion (use wrench to secure manifold when re-attaching orifice). d Look here for the orifice identification Apply thread sealant to the LP orifice prior to installation. Use the chart below to identify the correct orifices. NG #36 LP #52 c Slide the air shutters to provide access to the orifices. Rear Orifice 15/16" 23.8mm a b 9/16" Wrench 10/31/14 Installation (for qualified installers only) 47 © Travis Industries 4140731 100-01372 8. The stepper motor (adjustable regulator) has an installation sheet included with it – make sure to follow all of the directions. Place the stepper motor on the gas control valve (see below) – MAKE SURE IT IS CORRECTLY ORIENTED. Secure using the screws included with the motor – tighten to 25 Lb-inches. Leak test this area after installation to verify proper installation. 9. Replace the burner. Push the burner to the left side to insure the manifold inserts over the orifice. 10. Replace the remaining firebox components. 11. Replace the glass. 12. Make the gas line connection, bleed the gas line (if applicable), start the heater and thoroughly leak-test all gas connections and the gas control valve. 10/31/14 48 Installation (for qualified installers only) © Travis Industries 4140731 100-01372 Wiring Diagram Caution: Label all wires prior to disconnection when servicing controls. Wiring errors can cause improper and dangerous operation.Orange Yellow System Jumper Purple Grey Pilot Sensor Spark Rod Battery Box (Manual On/Off) Accent Light (s) 3 Amp Fuse Optional Blower(s) 3 Amp Fuse Appliance Ground Accessory Power Appliance Ground Green Orange Yellow / Green White Blue IPI/CPI JUMPER WIRE Blue Pink Power In TOP (4) AA Batteries Black Red Yellow Orange Yellow Flame Detect Black Red Purple Grey Black White Green Integrated Fireplace Control (IFC) 3.15A FUSE White Black White Black Black Black White White 10/31/14 Optional Equipment 49 © Travis Industries 4140731 100-01353 Power Heat Duct Installation Warning: All wiring should be done by a qualified electrician and shall be in compliance with local codes and with the current National Electric Code ANSI/NFPA 70 (in the U.S.), or with the current CSC22.1 Canadian Electric Code (in Canada). One or two optional power heat (98500769) ducts may be connected to this fireplace (top right and left of the fireplace). Follow the directions below to prepare the power heat duct connection (for each power heat duct used). Follow the directions included with the power heat duct for installation. NOTE: The power heat duct should be wired for direct operation (see wiring diagram below); 1. Remove the 4 screws on the power heat duct cover and remove the cover. 2 Remove the 2 screws on the outer cover plate and remove the cover. Hot (black) Common (white) Ground (green) Power Supply Hot (black) Common (white) Ground (green) Rheostat Junction Box Blower Assembly 10/31/14 50 Optional Equipment © Travis Industries 4140731 100-01353 3 Remove the 2 screws on the inner cover plate and remove the cover. 4 Loosen the single screw on the convection cover plate two turns. 5 Rotate the convection cover plate 180˚ (this allows heated air to flow upwards into the power heat duct). 10/31/14 Optional Equipment 51 © Travis Industries 4140731 100-01353 10/31/14 52 Index © Travis Industries 4130731 100-01353 Additional Items Required .................................. 7 Air Shutter Adjustment ..................................... 38 Altitude Considerations .................................... 21 Approved Vent ................................................. 21 Approved Vent Configurations ......................... 25 Clearances ......................................................... 9 Corner Installations .......................................... 16 Crushed Glass Installation ............................... 43 Diffuser ............................................................. 27 Dimensions ........................................................ 6 Drywall Supports .............................................. 32 Electrical Connection ....................................... 20 Exhaust Restrictor ............................................ 25 Fireback Installation ......................................... 41 Fireplace Placement Requirements ................... 9 Fuel .................................................................. 18 Gas Line Connection ........................................18 Gas Line Location ............................................ 19 Gas Line Requirements ................................... 18 Glass Frame Removal and Installation ............ 39 Hearth Requirements ....................................... 32 Heating Specifications ........................................6 Installation Options .............................................6 Intake Restrictor ............................................... 26 Listing Details ..................................................... 2 LP Conversion Instructions .............................. 44 Mantel Column Clearances ........................... 36 Mantel Requirements ....................................... 36 Massachusetts Approval .................................... 2 Massachusetts Requirements ........................... 8 Minimum Framing Dimensions ........................ 13 National Fireplace Institute ................................ 2 Overview ............................................................ 2 Packing List ........................................................ 7 Power Heat Duct Installation ........................... 49 Raised Fireplaces .............................................. 9 Recommended Installation Procedure .............. 7 Restrictor Position ............................................ 25 Safety Warnings ................................................. 4 Steps for Finalizing the Installation .................. 37 Termination Requirements .............................. 31 Vent Clearances .............................................. 21 Vent Firestop .................................................... 21 Vent Installation ............................................... 21 Vent Requirements .......................................... 21 Wiring Diagram ................................................ 48 10/31/14