Loading...
HomeMy WebLinkAboutB14-0408 REV1 load calcs.pdfDanici Electric, Inc. PO Box 7246 ~ Breckenridge, CO 80424 Phone (970) 390-1173 ~ Fax (970) 547-9221 sparky63@danicielectric.com November 18, 2014 Revision #3 Attn: Dave Dantas & Mikael Pukas D.W. Dantas Construction, LLC PO Box 2322 Avon, CO 81652 The following are Load Calculations for 1772 Alpine Drive, Vail, CO 81657: General Lighting 14,940VA Small Appliance 3,000VA Laundry 1,500VA TOTAL 19,440VA 3,000VA at 100% 3,000VA 19,440VA – 3,000VA 16,440VA 16,440VA at 35% 5,754VA NET LOAD 8,754VA Range 8,000VA Oven 4,000VA Dryer 5,000VA Steamer 8,000VA Elevator 4,500VA Add’l Small Appliance 1,500VA Two Exterior Receptacles 360VA Add’l Exterior Lighting 320VA NET CALCULATED LOAD 40,434VA 40,434VA /240V = 169A 169A TOTAL LOAD CALC 200A Service is Required Respectfully, David Novak Danici Electric, Inc.