HomeMy WebLinkAbout14077.00 - Solaris Clubhouse for Inspirato_Part3.pdfGENERAL NOTES:
1. ALL DUCTWORK DIMENSIONS ARE SHOWN INSIDE TO INSIDE.
2. ALL INTERIOR SUPPLY AND RETURN DUCTWORK SHALL INCLUDE 1" LINER
UNLESS OTHERWISE NOTED. ALL OUTSIDE AIR INTAKE AND ROUND
DUCTWORK SHALL BE WRAPPED WITH 1.5" THICK INSULATION UNLESS
OTHERWISE NOTED.
3. ALL FINAL DUCTWORK CONNECTIONS TO SUPPLY GRILLES (OR PLENUMS)
SHALL BE COMPLETED WITH ACOUSTICAL FLEXIBLE DUCT UNLESS
OTHERWISE NOTED AND A MAXIMUM LENGTH OF FIVE FEET.
4. ALL ROUND DUCT CONNECTIONS TO ROUND DUCTWORK SHALL BE
CONICAL TEES.
5. ALL SQUARE 90 DEGREE ELBOWS SHALL HAVE TURNING VANES.
6. ALL DUCTWORK SHALL BE RUN TIGHT TO UNDERSIDE OF STRUCTURE
WHERE IT EXISTS UNLESS OTHERWISE NOTED.
7. ALL DUCTWORK PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL
INCLUDE FIRE DAMPERS RATED TO MATCH THAT OF THE ASSEMBLY.
8. ALL SUPPLY GRILLES SHALL HAVE INCLUDE A BALANCING DAMPER
UNLESS OTHERWISE NOTED. IF THE DAMPER IS LOCATED IN AN
INACCESSIBLE LOCATION, CABLE-STYLE DAMPERS (ROTOTWIST OR
EQUIVALENT) SHALL BE INSTALLED AND SHALL BE ADJUSTABLE FROM
THE GRILLE FACE.
9. COORDINATE ALL ACCESS PANEL LOCATIONS WITH THE ARCHITECT.
10. ALL EXISTING HVAC PIPING SERVING FAN COILS TO REMAIN. VERIFY
ROUTING IN FIELD.
SHEET DETAIL NOTES:
REMOVE DUCTWORK IN THIS AREA, VERIFY IN FIELD.
RELOCATE TO THIS LOCATION.
REMOVE DUCTWORK AND DIFFUSER IN THIS AREA AND DISTRIBUTE
SUPPLY CFM BETWEEN SPECIFIED GRILLES. SEE NOTE 4.
RE-BALANCE DIFFUSERS FOR ADDITIONAL CFM. SEE NOTE 3.
DUCTWORK INTO ADJACENT SPACE, SHOWN FOR REFERENCE ONLY.
SHIFT DIFFUSERS TO ALLOW CLEARANCE FOR NEW SPACE:
103-CLOSET.
VENT FIREPLACE UP THROUGH SHAFT TO UN-INHABITABLE DECK
ABOVE. SEE SECTION DETAIL 1. COORDINATE FLUE ROUTING WITH
OUTSIDE AIR DUCT WORK IN THIS SHAFT. PROVIDE 2 HR FIRE
STOPPING COLLAR ON THE SHAFT PENETRATION (I.E. HILTI CP 644 10").
REPLACE EXISTING PERFORATED DIFFUSER & MATCH EXISTING 33X12
RETURN.
TERMINATE (2) 10" FIRE PLACE FLUES MIN. 12" ABOVE GREEN DECK.
INSTALL ELECTRIC MATT AS A SNOW MELT TO ALLOW 12" CLEARANCE
ABOVE THE DECK.
EXISTING MOTORIZED DAMPER TO REMAIN.
RELOCATE RETURN GRILLE TO CENTER OF ROOM. COORDINATE WITH
EXISTING DUCTWORK IN THIS LOCATION.
EXISTING DUCTWORK TO REMAIN.
EXISTING FAN COILS TO REMAIN.
1
2
+44
+48
LCD
LCD
N.I.C.
N.I.C.
N.I.C.
LOUNGE 3
104
BAR
103
CLOSET
101
LOUNGE 6
107
THEATRE
108
SALES
109
MEN'S W.C
111
VANITY
110
WOMEN'S
W.C.
112
WORK
114
EMPLOYEE
BREAK
116
LOUNGE 4
105
LOUNGE 5
106
+84
+84
+84
+84
+84
+84
+48
+48
+44
+44
+60
+44
REF.
+48
+84
+84
+84
+84
+48
+48
+48
EL
EL
+48
+48
EL
JAN.
117
LCD
LCD
+84
+44
+84
+44
D/W
+44
M/W (2)
ICE MAKER
BOTTLE COOLER
ICE WELL
DRYING
RACK
GLASS
CHILLER
PREP SINK
SODA
COFFEE
KEG
+20
+20
+20
+20
+20
+20
+20
+20
+20
+20
+20
+44
+44
+44
+48
+48
+48
+48
+36
+36
+36
+36
(E) 6" OSA WITH BACKDRAFT
DAMPER TO REMAIN
2
1
1
1
2
2
1
1
2
1
1
2
1
1
2
1
2
2
2
3
3
A
225-S
24X4
A
225-S
24X4
A
115-S
24X4
A
250-S
48 X 4
A
255-S
48X4
A
220-S
48X4
A
235-S
48X4
A
235-S
48X4
A
110-S
24X4
A
400-S
48X4
A
400-S
48X4
(E) FC-2
(E) 24 X 12
(E) 24 X 12
ߛ(ߜ
(E) 24 X 12
(E) 36 X 20
(E) 22 X 12
BDD
BDD
(E) FC-1
(E)22 X12
(E)TOILET EXHAUST
(E) 8 X 10 (UNLINED)
(E)10 X 10(UNLINED)
(E) 36 X 12
RETURN
48" B-RELIEF
(EXISTING)
48" B-RELIEF
4
4
4
(E) DUCTWORK TO REMAIN
5
5
5
5
5 5
6
6
ELECTRIC
SNOW MELT
MATT
ON THE GREEN
DECK ABOVE
7
7
8
9
10
11
8
3'
13.5 SQ FT
9
10
(E) O.A. DUCT UP
11
INSPIRATO
SPACE
(E) DECK
GREEN DECK
(E) AIR INTAKE LOUVER
ELECTRIC
SNOW MELT MATT
TO ALLOW
CLEARANCE PER
MANUFACTURER
MIN. 12"
FP EXHAUST CAP
M2.0
1
L
1
300-O.A.
36X18
(EXISTING)
L
1
300-O.A.
36X18
NOTE: FUTURE INSTALLATION UNDER SEPARATE PERMIT UPON
APPROVAL FROM HOA AND TOV. PROVIDE ROUGH-IN ONLY. SHOWN
FOR REFERENCE ONLY.
NOTE: FUTURE INSTALLATION UNDER
SEPARATE PERMIT UPON APPROVAL FROM
HOA AND TOV. PROVIDE ROUGH-IN ONLY.
SHOWN FOR REFERENCE ONLY.
3"
6
6
6
(E) 24 X 12
12
13
13
13
12
1
B
1270-R
36X12
2
EF
1
EF
1
of
Drawn By: Checked By:
DATE: ISSUE:
10-27-14 PERMIT
AEC PROJECT #: INSPIRATO
141 E MEADOW DR
SUITE 204
VAIL, COLORADO 81657
14077.00
www.aec-vail.com
CMechanical,
Electrical & Lighting Design Services
Architectural Engineering
Consultants
Telephone: 970-748-8520 Fax: 970-748-8521
EG$Q2IILFHZLWK/(('
$FFUHGLWHG
3URIHVVLRQDOV
11-06-14
EM LIGHT CLARIF.
1
11-12-14 BLDG DEPT COMM #2
2
11-24-14 REVISION #3
3
%92 61%
0&.'8'.
*8#%
2.#0
5%#.'Ä
/Ä
NORTH
2ND LEVEL HVAC PLAN
SCALE: 1/4" = 1'0"
SECTION DETAIL 1
NO SCALE
12/17/14