HomeMy WebLinkAbout14077.00 - Solaris Clubhouse for Inspirato_Part6.pdfGENERAL NOTES: 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 3. P.C. TO INSTALL ALL WASTE LINES THROUGH THE FLOOR ON THIS LEVEL TO AVOID DISRUPTION OF LOWER LEVEL TENANTS. VERIFY SUCH INSTALLATION PRIOR TO WORK. 4. IF INDIRECT WASTE IS LONGER THAN 5' TO TERMINATION POINT, PROVIDE P-TRAP. +44 +48 LCD LCD N.I.C. N.I.C. N.I.C. LOUNGE 3 104 BAR 103 CLOSET 101 LOUNGE 6 107 THEATRE 108 SALES 109 MEN'S W.C 111 VANITY 110 WOMEN'S W.C. 112 WORK 114 EMPLOYEE BREAK 116 LOUNGE 4 105 LOUNGE 5 106 +84 +84 +84 +84 +84 +84 +48 +48 +44 +44 +60 +44 REF. +48 +84 +84 +84 +84 +48 +48 +48 EL EL +48 +48 EL JAN. 117 LCD LCD +84 +44 +84 +44 D/W +44 M/W (2) ICE MAKER BOTTLE COOLER ICE WELL DRYING RACK GLASS CHILLER PREP SINK SODA COFFEE KEG +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +44 +44 +44 +48 +48 +48 +48 +36 +36 +36 +36 LV-1 1 PS-1 6 5 8 7 9 6 CONNECT 1-1/2" W & V TO LV-1. ROUTE 1-1/2" W FROM LV-1 TO SP-2a OR b, RE: FLOOR PLAN. CONNECT 3" W & 2" V TO WC-1. ROUTE 3" W FROM WC-1 TO SP-2a OR b, RE: FLOOR PLAN. WC-1 FIXTURE MUST ALLOW SIDE CONNECTION. CONNECT 1-1/2" I.W. FROM HS-1 VIA AIR GAP TO FS-1b. CONNECT 2" I.W. FROM KS-2 VIA AIR GAP TO FS-1b. INSTALL SP-1, IN THE FAKE COLUMN AND FS-1a & b UNDER THE CABINET'S COUNTER TOP IN THE PROPOSED LOCATIONS. COORDINATE EXACT LOCATION IN FIELD WITH OTHER BAR EQUIPMENT AND SPACE AVAILABLE. CONNECT 2" I.W. FROM PS-1 VIA AIR GAP TO FS-1a. DELETED. CONNECT 1-1/2" W SP-1 DISCHARGE TO EXISTING WASTE LINE IN THIS LOCATION. VERIFY EXISTING WASTE LOCATION IN FIELD PRIOR TO WORK. CONNECT SP-1 DISCHARGE TO THE EXISTING WASTE FROM TOP. THIS FS-1a CAN BE OMITTED IF INDIRECT WASTE LINE CAN MAINTAIN CODE REQUIRED SLOPE TO SP-1. VERIFY IN FIELD PRIOR TO PURCHASING FS-1a. (E) 6" W TO ADJACENT SPACE TO REMAIN. VERIFY EXACT LOCATION IN FIELD. ROUTE 1-1/2" W & 2" V FROM SP-1 THRU THE COLUMN UP TO THE CEILING. COORDINATE EXACT LOCATION IN FIELD AND AVOID OTHER PLUMBING PIPING CONFLICT. MAINTAIN SLOPE TOWARDS SP-1. CONNECT 2" W FROM MS-1 TO SP-3. RE: MANUFACTURER'S INSTALLATION INSTRUCTIONS. TRAP SHALL BE PROVIDED INSIDE THE SP-3 PIT AS PER MANUFACTURER'S INSTALLATION DETAIL. MAINTAIN 2% SLOPE OF THE 1-1/2" PUMP DISCHARGE LINE IN THE CEILING TOWARDS THE PUMP. COORDINATE WITH EXISTING MECHANICAL & PLUMBING EQUIPMENT INSTALLED IN THE CEILING CAVITY. WHERE THE SLOPE TOWARDS THE PUMP CANNOT BE MAINTAINED, PROVIDE CLEANOUT AND ACCESS, SEE DIAGRAM ON P1.1 LOCATE NEAREST EXISTING 2" OR LARGE WASTE IN THIS LOCATION AND CONNECT 1-1/2" SP-3 WASTE DISCHARGE TO IT. CONNECT FROM TOP. LOCATE NEAREST 2" OR LARGE VENT LINE IN THIS LOCATION AND CONNECT SP-3 2" VENT TO IT. SLOPE TOWARDS SP-3. LOCATE NEAREST EXISTING 2" OR LARGE WASTE IN THIS LOCATION AND CONNECT 1" SP-2a,b WASTE DISCHARGE TO IT. CONNECT FROM TOP.LOCATE NEAREST 2" OR LARGE VENT LINE IN THIS LOCATION AND CONNECT SP-2a,b 2" VENT TO IT. SLOPE TOWARDS SP-2a,b. CONNECT DRAIN AND CONDENSATE DRAIN FROM IM-1 TO KS-1 VIA AIR GAP OR VACUUM BREAKER. DELETED. CONNECT 2" W & 1-1/2" V TO KS-1. ROUTE 2" W FROM KS-1 IN THE WALL TO SP-2a, SLOPE 2% TOWARDS SP-2a. VERIFY SLOPE IN FIELD PRIOR TO WORK. IF SLOPE CANNOT BE PROVIDED, ADD ANOTHER SUMP PUMP (SP-2c - NOT IN THE SCHEDULES, MATCH SP-2a,b) LOCATE EXISTING 2" OR LARGER VENT IN THIS AREA AND CONNECT 1-1/2" V TO IT. SHEET DETAIL NOTES: 1 2 3 4 10 8 (E) 6" W 10 11 KS-1 MS-1 12 12 13 14 14 IM-1 1-1/2" V 1-1/2" W LV-1 1 WC-1 2 WC-1 2 1-1/2" V 1-1/2" V 1-1/2" V 1-1/2" V DN SP 1 HS-1 3 KS-2 4 1-1/2" W 2" W 2" W 2" W 2" W 1-1/2" W 2" W ACCESS TO SP-1 5 5 5 9 11 13 15 15 2" V 2" V 16 16 FS-1a FS-1b SP 2a 1-1/2" W 1-1/2" W 1" W SP 2b 2" W 1-1/2" V 1" W 1" W (E) 3" W DT-1 2" V SP 3 17 18 18 19 19 3 3 3 3 3 3 3 3 3 3 3 3 3 3 3 of Drawn By: Checked By: DATE: ISSUE: 10-27-14 PERMIT AEC PROJECT #: INSPIRATO 141 E MEADOW DR SUITE 204 VAIL, COLORADO 81657 14077.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 Fax: 970-748-8521 EG$Q2IILFHZLWK/(('Œ $FFUHGLWHG 3URIHVVLRQDOV 11-06-14 EM LIGHT CLARIF. 1 11-12-14 BLDG DEPT COMM #2 2 11-24-14 REVISION #3 3 %92 61% 0&.'8'. 2.7/$+0) ߙ9#56' 2.#0 5%#.'žÄ 2Ä   NORTH 2ND LEVEL PLUMBING PLAN SCALE: 1/4" = 1'0" 12/17/14