Loading...
HomeMy WebLinkAbout14077.00 - Solaris Clubhouse for Inspirato_Part7.pdfGENERAL NOTES: 1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE STRUCTURAL ENGINEER. 2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY. 3. COORDINATE ALL HOSE BIBB AND WALL HYDRANT LOCATIONS WITH THE ARCHITECT. +44 +48 LCD LCD N.I.C. N.I.C. N.I.C. LOUNGE 3 104 BAR 103 CLOSET 101 LOUNGE 6 107 THEATRE 108 SALES 109 MEN'S W.C 111 VANITY 110 WOMEN'S W.C. 112 WORK 114 EMPLOYEE BREAK 116 LOUNGE 4 105 LOUNGE 5 106 +84 +84 +84 +84 +84 +84 +48 +48 +44 +44 +60 +44 REF. +48 +84 +84 +84 +84 +48 +48 +48 EL EL +48 +48 EL JAN. 117 LCD LCD +84 +44 +84 +44 D/W +44 M/W (2) ICE MAKER BOTTLE COOLER ICE WELL DRYING RACK GLASS CHILLER PREP SINK SODA COFFEE KEG +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +20 +44 +44 +44 +48 +48 +48 +48 +36 +36 +36 +36 (E) 1-1/4" DCW (E) 3/4" DCW LV-1 1 LV-1 1 WC-1 2 WC-1 2 KS-1 4 KS-2 HS-1 MS-1 WH 1 19 PP 1 3 SHEET DETAIL NOTES: 2 CONNECT 1/2" CW & HW TO LV-1. CONNECT 1/2" CW TO WC-1. CONNECT 1/2" CW & HW TO HS-1. CONNECT 3 4" CW & 3 4" HW TO KS-1. DELETED. CONNECT 1/2" CW & HW TO PS-1. CONNECT 3/4" CW & HW TO MS-1. PROVIDE EITHER A HOSE CONNECTION VACUUM BREAKER (WATTS 8B OR EQUIVALENT) OR INLINE FAUCET VACUUM BREAKER OUTLET (CHICAGO FAUCETS E22JKCP OR EQUIVALENT). VERIFY LOCATION OF EXISTING GAS LINE IN FIELD. EXISTING GAS LINE TO REMAIN. ADD GAS SUB-METER, INSTALL AS CLOSE TO (E) ACCESS PANEL IN THIS LOCATION AS POSSIBLE. COORDINATE MODEL AND MAKE OF THE SUB-METER WITH BUILDING MANAGERS REQUIREMENTS. CONNECT 3 4" G TO FP-2 (OR AS PER MANUFACTURER). CONNECT 1 2" G TO FP-1 (OR AS PER MANUFACTURER). ADD DOMESTIC COLD WATER SUB-METER. COORDINATE THE MAKE AND MODEL OF THE SUB-METER WITH MANAGERS REQUIREMENTS. PROVIDE A NEW ACCESS PANEL IF NEEDED (OR VERIFY EXISTING IN FIELD). ROUTE PIPING UNDER THE COUNTER TOP. VERIFY (E) GAS LINE LOCATION IN FIELD, IF LOCATED IN THIS LOCATION, CONNECT TO IT. COORDINATE WITH BUILDING MANAGER. (E) 3/4" CW TO ADJACENT SPACE TO REMAIN. PROVIDE BALANCING VALVE UNDER THE COUNTER TOP. SET @ 0.5 GPM. VERIFY (E) GAS LINE ROUTING IN FIELD. ROUTE 3/4" CW & HW AND CONNECT 1/2" CW & HW TO EACH FAUCET OF KS-2. ROUTE PLUMBING PLUMBING DOWN IN THE COLUMN FURR-OUT. COORDINATE IN FIELD. WATER HEATER SHOWN OFFSET FOR CLARITY. INSTALL EMERGENCY PAN UNDER THE HEATER. DRAIN PAN TO MS-1 VIA AIR GAP. 1 4 6 3 5 9 7 8 10 7 8 (E) 4" G 3/4" HW 3/4" CW 9 9 10 11 11 FP-2 12 FP-1 12 13 13 14 (E) 3" G 3/4" CW 3/4" HW 3/4" CW 3/4" HW 1/2" HWC 3/4" CW 3/4" CW 1/2" HW 1/2" HW 1" CW 1" CW 1/2" HW 1-1/4" CW 1/2" G 3/4" G 3/4" G 15 15 (E) MAIN CW ENTRY AS PER (E) M2.0E REMODEL OF SUITES 204 & 205 FROM 04/11/2014, FIELD VERIFY 16 16 17 17 18 18 IM-1 1/2" CW 3/4" CW (E) 1-1/2" G PS-1 6 SM-1 1/2" CW 1/2" HW 1/2" HWC 3/4" CW 3/4" HW 3/4" CW 3/4" HW 1/2" HWC 1-1/4" CW 3/4" HW 1/2" HWC 1-1/4" CW 3/4" HW 1/2" HWC 1" CW 3/4" HW 1" CW 1" HW 1/2" HWC 3/4" CW 3/4" HW ACCESS PANEL 14 14 14 19 20 20 ACCESS PANEL 21 21 3 3 3 3 3 3 3 3 of Drawn By: Checked By: DATE: ISSUE: 10-27-14 PERMIT AEC PROJECT #: INSPIRATO 141 E MEADOW DR SUITE 204 VAIL, COLORADO 81657 14077.00 www.aec-vail.com CMechanical, Electrical & Lighting Design Services Architectural Engineering Consultants Telephone: 970-748-8520 Fax: 970-748-8521 EG$Q2IILFHZLWK/(('Œ $FFUHGLWHG 3URIHVVLRQDOV 11-06-14 EM LIGHT CLARIF. 1 11-12-14 BLDG DEPT COMM #2 2 11-24-14 REVISION #3 3 %92 61% 0&.'8'. &1/'56+% 9#6'4ߙ )#52.#0 5%#.'žÄ 2Ä   NORTH 2ND LEVEL DOMESTIC WATER PLAN SCALE: 1/4" = 1'0" 12/17/14