HomeMy WebLinkAbout14077.00-Solaris Clubhouse for Inspirato_Part7.pdfGENERAL NOTES:
1. OFFSET PIPING AS REQUIRED TO AVOID ALL DUCTWORK, LIGHTS, AND
STRUCTURE. COORDINATE ALL STRUCTURAL PENETRATIONS WITH THE
STRUCTURAL ENGINEER.
2. ALL PIPING PASSING THROUGH FIRE-RATED ASSEMBLIES SHALL INCLUDE
A FIRE-RATED PIPE SEALANT RATED TO MATCH THAT OF THE ASSEMBLY.
3. COORDINATE ALL HOSE BIBB AND WALL HYDRANT LOCATIONS WITH THE
ARCHITECT.
DN
+44
+48
LCD
LCD
N.I.C.
N.I.C.
N.I.C.
LOUNGE 3
104
BAR
103
CLOSET
101
LOUNGE 6
107
THEATRE
108
SALES
109
MEN'S W.C
111
VANITY
110
WOMEN'S
W.C.
112
WORK
114
STOR.
115
EMPLOYEE
BREAK
116
LOUNGE 4
105
LOUNGE 5
106
+84
+84
+84
+84
+84
+84
+48
+48
+44
+44
+60
+44
REF.
+48
+84
+84
+84
+84
+48
+48
+48
EL
T/E
EL
+48
+48
EL
JAN.
117
LCD LCD
+84
+44
+84
+44
D/W
+44
M/W (2)
ICE MAKER
BOTTLE COOLER
ICE WELL
DRYING
RACK
GLASS
CHILLER
PREP
SODA
COFFEE
KEG
+20
+20
+20
+20
+20
+20
+20
+20 +20
+20
+20
+44
+44
+44
(E) 1-1/4" DCW
(E) 3/4" DCW
LV-1 1
LV-1 1
WC-1
2
WC-1
2
KS-1
4
DW-1
KS-2
HS-1
MS-1
19
PP
1
WH
1
3
SHEET DETAIL NOTES:
2
CONNECT 1/2" CW & HW TO LV-1.
CONNECT 1/2" CW TO WC-1.
CONNECT 1/2" CW & HW TO HS-1.
CONNECT 3
4" CW & 3
4" HW TO KS-1.
&211(&7)+:72DW PER MANUFACTURER.
CONNECT 1/2" CW & HW TO PS-1.
CONNECT 3/4" CW & HW TO MS-1. PROVIDE EITHER A HOSE
CONNECTION VACUUM BREAKER (WATTS 8B OR EQUIVALENT) OR
INLINE FAUCET VACUUM BREAKER OUTLET (CHICAGO FAUCETS
E22JKCP OR EQUIVALENT).
VERIFY LOCATION OF EXISTING GAS LINE IN FIELD.
EXISTING GAS LINE TO REMAIN.
ADD GAS SUB-METER, INSTALL AS CLOSE TO (E) ACCESS PANEL IN
THIS LOCATION AS POSSIBLE. COORDINATE MODEL AND MAKE OF THE
SUB-METER WITH BUILDING MANAGERS REQUIREMENTS.
CONNECT 3
4" G TO FP-2 (OR AS PER MANUFACTURER).
CONNECT 1
2" G TO FP-1 (OR AS PER MANUFACTURER).
ADD DOMESTIC COLD WATER SUB-METER. COORDINATE THE MAKE
AND MODEL OF THE SUB-METER WITH MANAGERS REQUIREMENTS.
PROVIDE A NEW ACCESS PANEL IF NEEDED (OR VERIFY EXISTING IN
FIELD).
ROUTE PIPING UNDER THE COUNTER TOP.
VERIFY (E) GAS LINE LOCATION IN FIELD, IF LOCATED IN THIS
LOCATION, CONNECT TO IT. COORDINATE WITH BUILDING MANAGER.
(E) 3/4" CW TO ADJACENT SPACE TO REMAIN.
PROVIDE BALANCING VALVE UNDER THE COUNTER TOP. SET @ 0.5
GPM.
VERIFY (E) GAS LINE ROUTING IN FIELD.
ROUTE 3/4" CW & HW AND CONNECT 1/2" CW & HW TO EACH FAUCET
OF KS-2.
ROUTE PLUMBING PLUMBING DOWN IN THE COLUMN FURR-OUT.
COORDINATE IN FIELD.
1
4
6
3
5
9
7
8
10
5
7
8
(E) 4" G
3/4" HW
3/4" CW
(E) 4" G
9
9
10
11
11
FP-2
12
FP-1
12
13
13
14
(E) 1-1/2" G
(E) 3" G
(E) 4" G
3/4" CW
3/4" HW
3/4" CW
3/4" HW
1/2" HWC
3/4" CW
3/4" CW
1/2" HW
1/2" HW
1" CW
1" CW
1/2" HW
1-1/4" CW
1/2" G
3/4" G
3/4" G
(E) ACCESS PANEL
TO REMAIN
15
15
(E) MAIN CW ENTRY
16
16
17
17
18
18
18
18
(E) 1-1/2" G TO REMAIN
IM-1
1/2" CW
3/4" CW
(E) 1-1/2" G
PS-1
6
SM-1
1/2" CW
1/2" HW
1/2" HWC
3/4" CW
3/4" HW
3/4" CW
3/4" HW
1/2" HWC
1-1/4" CW
3/4" HW
1/2" HWC
1-1/4" CW
3/4" HW
1/2" HWC
1" CW
3/4" HW
1" CW
1" HW
1/2" HWC
3/4" CW
3/4" HW
ACCESS PANEL
14
14
14
19
20
20
2
2
2
2
2
2
2
2
of
Drawn By: Checked By:
DATE: ISSUE:
10-27-14 PERMIT
AEC PROJECT #: INSPIRATO
141 E MEADOW DR
SUITE 204
VAIL, COLORADO 81657
14077.00
www.aec-vail.com
CMechanical,
Electrical
& Lighting
Design Services
Architectural Engineering
Consultants
Telephone: 970-748-8520 Fax: 970-748-8521
EG$Q2IILFHZLWK/(('
$FFUHGLWHG
3URIHVVLRQDOV
11-06-14
EM LIGHT CLARIF.
1
11-12-14 BLDGDEPT COMM #2
2
%92 61%
0&.'8'.
&1/'56+%
9#6'4ߙ
)#52.#0
5%#.'Ä
2Ä
NORTH
2ND LEVEL DOMESTIC WATER PLAN
SCALE: 1/4" = 1'0"
12/17/14