HomeMy WebLinkAboutInspirato_ID-102_DIMENSION PLAN.pdfDN
LOUNGE 3
104
CLOSET
101
BAR
103
LOUNGE 6
107
THEATRE
108
SALES
109
MEN'S W.C
111
VANITY
110
WOMEN'S
W.C.
112
WORK
114
EMPLOYEE
BREAK
116
ID-201
11 10
ID-201
9 8 ID-201
6
ID-201
5
4
5'-0"
4'-7"
2'-0"
3'-0"
6'-9"
90°
90°
6'-5"4'-6"7'-4"
HOLD
5'-0"
6'-7" ±
HOLD
5'-0"
7'-4"6'-11"
3'-0"
5'-0"
12'-11"
N.I.C.
N.I.C.
N.I.C.
ID-200
13
ID-200
1
A1
A1
A1
A1
2 '-0"
A1
ID-200
11
ID-200 16
12
ID-200
15
ID-200
14
ID-200
8
ID-200
10
ID-200
9
ID-200
2
ID-200
4
5
ID-201
2
3
ID-200
6
ID-200 17
3
LOUNGE 4
105
LOUNGE 5
106
ID-200
718'-5 1/4"
8'-9"
A4 3'-3"
A5
15'-11"
2'-7"JAN.
117
A3
A3
A2
ID-102
5
TYP. ALIGNA7
A2
MIN1'-2"
ALIGN
12'-11"A2
A7
A7
A7
A7 ALIGNALIGNALIGN
ALIGN
ALIGN
R= 2'-3"
2'-0"4'-10" ±16'-10"EQEQ
ID-201
7
2'-6"
3'-6" MIN
A8
1'-0"
ID-201
1
LOUNGE 2
102
ID-201
7
SIM
A2
A7
A7
8'-4"
2'-4"
2'-4"
7'-8"
2'-4"
8'-3" ±
A4
TYP
7"
6'-5"2'-4"5'-6"
45°
3'-1" ±
1'-10"2'-6"1'-10"2'-7"
11'-5" ±
3'-7"
2'-3 1/4"2'-0"
2'-0"1'-6"
3'-2"
A.F.F.
ID-201
12
A6
M/W (2)
REF.
2"
18
ID-108
2
5'-0"
UP
2'-10"
A9 A9
30"X42" 30"X42"
A9
30"X42"
2'-8"
1'-6"
CLEAR
2'-3"
3
A10
3
3
3
PARTITION SCHEDULE
Base building shell and core construction /
existing partition to remain.
Building standard interior tenant partition.
•3-5/8" metal stud framing at 24" O.C. with
5/8" gyp. bd. both sides.
•Re: Detail 1/ID-100
Building standard tenant partition.
•3-5/8" metal stud framing at 24" O.C. with
5/8" gyp. bd. both sides.
•Partial height
•Re: Detail 2/ID-100
OR
EXISTING PERIMETER OR
PERPENDICULAR WALL
FLEXIBLE CHANNEL REVEAL
3-5/8 STEEL STUD DO NOT
ATTACH TO WALL
FINISH DRYWALL CUT BACK TO
ALLOW FOR SLIP JOINT
GASKET FOR SOUND
INSULATION
FLEXIBLE CHANNEL REVEAL
Slip Joint - Perpendicular
SCALE: 1-1/2" = 1'-0" 3
EXISTING PERIMETER OR
PERPENDICULAR WALL
FLEXIBLE CHANNEL REVEAL
3-5/8 STEEL STUD DO NOT
ATTACH TO WALL
FINISH DRYWALL CUT BACK TO
ALLOW FOR SLIP JOINT
GASKET FOR SOUND INSULATION
FLEXIBLE CHANNEL REVEAL
Slip Joint - Parallel
SCALE: 1-1/2" = 1'-0" 4
EXISTING CORE OR PARALLEL WALL
DIMENSION PLAN KEYNOTES
The Contractor shall be responsible for pricing
any materials and work required and related to
the various Key Notes. Contractor to provide and
install all items unless noted otherwise.
A1
New 5/8” thick gypsum board over metal stud
column furring. Provide furring tight to column for
minimal dimension from column, unless dimension
is specified.
A2
Metal stud framing with 5/8" gypsum board to
align with face of projector screen or LED
television face. Verify final dimension with A/V
Vendor.
A3
Portion of partial height wall to align parallel to
existing shell wall.
A4
Align face of bar with corner of column furring.
A5
Bar top profile to be parallel with soffit above, RE:
RCP.
A6
4"x4" tube steel column to structure with
decorative mirror finish over fire-retardant
treated plywood. RE: Elevations and Sections
A7
New wood veneer pilasters: Align back side of
pilaster with crown molding above. Finish sides of
pilaster with wood veneer, side edges to align
with ceiling soffit above. RE: RCP
A8
Building standard interior partition with 6" studs to
accommodate relocated recessed electrical
panel.
A9
30" x 48" open area for wheelchair accessible
seating. At bar, countertop to be 34" maximum
above floor, to comply with ICC/ANSI A117.1
Section 902.2.
A10
Existing fire damper access: Remove damper
door, Provide new damper acess door flush with
new wall. Provide matching finish to blend with
adjacent wall finish.
3
4x4 TUBE STEEL COLUMN BOLTED
TO FLOOR STRUCTURE AT 24" O.C.
RE: FINISH PLAN FOR FLOOR
FINISHES AND BASE TREATMENT
ONE LAYER OF 5/8" GYPSUM
BOARD EACH SIDE OF 4x4 TUBE
STEEL COLUMN
Partial Height Wall
2
SCALE: 1/2" = 1'-0" Height Varies
VARIES
RE: FLOOR PLAN
FOR HEIGHTS
TOP CAP VARIES ACCORDING TO
LOCATION, RE: FLOOR PLANS AND
ELEVATIONS
ONE LAYER 5/8" TYPE 'X' GYPSUM
BOARD EACH SIDE OF 3-5/8" 25
GA METAL STUDS SPACED 24"
O.C.; TAPE FULL HEIGHT SMOOTH
FINISH BELOW CEILING TRIM
B/SLAB
RE: FINISH PLAN FOR FLOOR
FINISHES AND BASE TREATMENT
5/8" GYPSUM BOARD CEILING
45 DEGREE BRACING @4'-0" O.C.,
ANCHOR TO TOP TRACK OF
PARTITION. ALTERNATE
LOCATIONS
TOP TRACK, ANCHORED TO
DIAGONAL BRACING W/ (3) #10
TEK SCREWS MIN.
Tenant Partition
1
SCALE: 1/2" = 1'-0" Floor to Ceiling
DIMENSION PLAN GENERAL NOTES
Contact the Architect for dimensions not
supplied. Do not scale drawings.
All dimensions are to finished face of drywall,
unless noted otherwise.
Contractor to provide level 4 finished surface on
all existing drywall perimeter and core walls.
General contractor, architect, and millworker to
confirm all dimensions in field.
Contractor to provide level 5 finish at all drywall
ceilings.
All new partitions adjoining perimeter walls to
have vertical slip joint connection. Ref Detail 1,
this sheet
All new partitions adjoining existing core walls to
have vertical slip joint connection. Ref Detail 2,
this sheet
84°
89°±
9 7°
90°
2'-0"2'-0"
12'-8 3/4"
A.F.F.
A.F.F.
2'-0"
2'-0"
1'-0"6"1'-0"
1'-0"6"1'-0"
3'-6"
2'-10"
Elsy Studios
1745 Wazee Street, Suite 2D
Denver, Colorado 80202
303.479.4952
ISSUE DATE ISSUE
SHEET NUMBER
DESCRIPTION
PROJECT
BUILDING
PROJECT MANAGER
GENERAL INFORMATION
ARCHITECT
ENGINEER
FILE NAME:
TOWN APPROVAL
C:\Users\nathan.ELSYSTUDIOS\Documents\Inspirato_nathan.rvt
INSPIRATO - MEMBER LOUNGE
141 EAST MEADOW DRIVE,
STE 204
VAIL, CO 81657
SARAH ZALES
OCTOBER 27, 2014 PERMIT DRAWINGS
141 EAST MEADOW DRIVE,
STE 204
VAIL, CO 81657
ID-102
DIMENSION PLAN
1410.01
INSPIRATO - MEMBER LOUNGE
NOVEMBER 12, 2014 BAR EQUIPMENT AND GENERAL
DESIGN UPDATES
NOVEMBER 12, 2014 BUILDING DEPARTMENT
RESPONSE
NOVEMBER 20, 2014 CONSTRUCTABILITY
COORDINATION
NORTH
DIMENSION PLAN
1/4" = 1'-0"
SCALE: 1/4" = 1'-0"
ENLARGED PLAN 5
1
2
3
12.1.2014
12/17/14