HomeMy WebLinkAboutInspirato_ID-105_REFLECTED CEILING PLAN.pdfS
S
S
S
9'-0"
9'-4"
9'-0"
9'-0" 2'-1"
2'-1"
2'-2"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
2'-0"
4'-4"
C4
C6
C10
C6
C10
C8
C10
C6
C11
C1
C6
C1
C11
C11
C11
C10
6'-6"
C6
9'-0"
9'-4"
9'-4"
9'-0"
9'-0"
9'-0"
9'-0"
9'-0"
7'-0"
C1
C1
N.I.C.
N.I.C.
N.I.C.
C13
7
ID-300
L8
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L10
L13
L13
L11
L11
L11
L2
L2
L2
L2
L7
L7
L7 L7
L7
L7
L7
L7
L7
L7
L4
L4
L5
104
103
101
107
108
109
111
110
112
114
116
105
106
8'-10"
C12
9'-4"
9'-0"
9'-0"
9'-4"
L2
L2
L2
L2
C6
ALIGN (TYP.)
ALIGN (TYP.)
L12
L12
C5
C5
100
102
113
2'-0"
2'-1"
L5
L7
L7
L7
4'-0"
5'-0"
L7
L7
L7
L7
8'-8"
9'-0"
9'-4"
9'-0"
9'-0"
8'-10"
9'-0"
9'-4"
9'-4"
9'-0"
9'-0"
9'-0"
9'-0" 9'-4"
9'-0"
9'-4"
9'-0"
9'-4"
9'-0"
9'-4"
9'-6"
117
L2
L8
L8 L8
L4
L4
L4
3
ID-300
1
ID-300
2
ID-300
EQEQEQL2
L2
L2
L2
L2
L2
L10
L10
L10
L10
L10
L10
L10
L11
L11
L11
L11
L11
L11
L10
L11
L10
L10
C14
C14
C10
C10
C10
C15
C15
C15
C15
C15
C15
C15
BAR
C10
C7
C7
C7
C1
9'-4"
C16
C10
9'-4"
L13
8'-6"
C9
C10
C10
C17
C12
EQ EQ EQ
C12
C12
L7 L7
L7
L7
8'-8" EQEQ
C12
J J
A/V
EL 3'-6"5'-11"5'-9 3/4"7'-8"3'-0 1/2"
L10
L13
9'-4"
TYP.
L14
TYP
C10
C17
C2 C3
8'-10"
1'-11"EQEQEQ1'-11"
9'-4"
EQ EQ EQ EQ EQ
10"
C18
C18
3
3
3
8'-10"
3
C9
+72" 3
+72" 3
+72" 3
+72" 3
+72"
3
+72" 3
+72"
3
8'-10"
+86.5"
+86.5"
+86.5"
+86.5"
3
3
PARTITION SCHEDULE
Base building shell and core construction /
existing partition to remain.
Building standard interior tenant partition.
•3-5/8" metal stud framing at 24" O.C. with
5/8" gyp. bd. both sides.
•Re: Detail 1/ID-100
Building standard tenant partition.
•3-5/8" metal stud framing at 24" O.C. with
5/8" gyp. bd. both sides.
•Partial height
•Re: Detail 2/ID-100
OR
REFLECTED CEILING PLAN GENERAL NOTES
All luminaires, electrical equipment, and devices
are new to be provided and installed by the
contractor, unless noted otherwise.
Provide and install Building Standard sprinkler
system, fire extinguishers, emergency lights, and
exit signage. Assure all compliance pertaining to
fire suppression system, electrical and
mechanical systems as required by the Building
Department.
All materials are assumed to be new unless
otherwise noted.
Contractor to confirm ducts and other
obstructions and notify Architect of any conflicts.
Qualified contractors shall possess the Means to
order specified products in time to meet the
Schedule. Architect will not accept substitutes
for products not ordered in a timely manner.
Contractor to confirm lead times at time of Bid.
All light fixtures to be ordered with Quick Ship
option, if applicable. Contractor may provide
and install temporary substitutes for unique
Decorative Fixtures and/or other Specialty
products, upon Architect's approval and at no
additional cost to Tenant.
Location of all access doors in drywall ceilings to
be approved by Architect. Paint doors,
hardware, and trim to match ceiling.
All adjacent multiple light switches & controls to
be ganged w/ single cover plate, w/ labels.
All device covers installed on wallcovering shall
be covered with matching finish.
All device covers on millwork or tile walls shall be
brushed stainless finish.
All drywall ceilings finished to Level 5 finish.
REFLECTED CEILING PLAN FIRE PROTECTION
GENERAL NOTES
The Contractor shall employ a Licensed Fire
Protection Engineer to prepare complete Fire
Alarm Construction Documents. Contractor shall
relocate and provide new Fire Alarm devices as
determined by the Fire Protection Engineer, (the
quantities of devices shown on the Partition Plan
are conceptual and approximate.) Provide all
additional equipment (zone cards, power
supplies, etc…) required for a complete and
operational Fire Alarm system in compliance with
local jurisdiction. The horn/strobe units shall sound
on any alarm. Horns shall be capable of being
silenced without deactivating strobes. The
Contractor shall provide and submit to the local
jurisdiction, the complete shop drawings
stamped and signed by the licensed Fire
Protection Engineer.
REFLECTED CEILING PLAN KEYNOTES
LINE ITEM OPTION
Provide dimming lighting controls by Lutron or
equal throughout.
C1
New metal framed soffit to align with millwork
table below: drywall soffit to be at 8'-4 3/4"
A.F.F. to accommodate 3/4" thick removable
wood veneer panel on Z clips to access light
canopy. Continue crown molding (no LED lights)
around soffit. Finished height to be
8'-6" A.F.F. RE: Elevations and Sections
C2
New concealed LED strip light on underside of
bar toe kick (entire perimeter).
C3
New concealed LED strip light to illuminate bar
front and server work surface (entire perimeter).
C4
New under cabinet concealed LED strip light to
illuminate backsplash (entire length).
C5
New concealed LED strip light to illuminate all
four sides of mirror.
C6
New paint-grade crown molding, profile design
TBD around perimeter of room as indicated to
conceal LED strip light for ceiling downlighting.
RE: Elevations & Sections
C7
New lowered gypsum board ceiling soffit with
crown molding along inside perimeter.
RE: Sections
C8
New concealed under cabinet LED strip light to
illuminate work surface (entire length).
C9
New gypsum board ceiling soffit. RE: Finish Plan
for applied finish
C10
New gypsum board ceiling throughout at
varying heights; Level 5 finish. RE: Finish Plan for
applied finish and Sections
C11
New gypsum board ceiling cove to conceal
LED strip light that provides uplighting.
C12
New fire-retardant treated wood blocking
concealed in soffit for support of Tenant's A/V
equipment.
C13 LINE ITEM OPTION
New recessed aluminum top and bottom track
for sliding screens. Dorma System or equal. Final
design to be determined.
C14
New 2'-0" x 2'-0" suspended acoustical grid
ceiling.
REFLECTED CEILING PLAN KEYNOTES
C15
New concealed LED light strip behind pilasters
to illuminate both sides of pilaster. End at top
of wainscoting. RE: Elevations
C16
New heat curtain to control temperature
inside. RE: Mechanical.
C17
Provide control joints at all drywall soffit to
exterior wall connections for spans longer than
20'-0" or per suggestion of contractor
C18
Provide separate switching for lights adjacent
to A/V display wall
3
REFLECTED CEILING PLAN LEGEND
R
Indicates existing fixture to remain.
All other devices shown are new
unless otherwise noted
N
Indicates new fixture to be provided
and installed by contractor. All
other fixtures are existing to remain.
Indicates relocated fixture.
E
L1 - Unassigned
L2 - Recessed downlight with
compact fluorescent lamping.
L4 - Ceiling mounted pendant fixture.
Damasco SP DAM 056, White
L5 - Ceiling mounted pendant fixture
Viso Cubie Suspension, Cluster of 5
L6 - Strip LED Fixture, continuous. RE:
Elevations and details for conditions
in millwork.
L8 - Ceiling mounted pendant fixture
Slamp Veli Gold (Qty. 3) Ceiling - Wall
Lamp (mini).
L7 - Recessed adjustable LED, 2"
diameter.
L9 - Ceiling mounted pendant fixture
Slamp Veli Gold (Qty. 1) Ceiling - Wall
Lamp (med. size)
L10 - Recessed LED adjustable fixture.
Delta Boxter, White, RE: plan for
revised layout and reduced quantity
L11 - Wall mounted dimmable sconce.
Axo Damasco AP DAM 030, White
L12 - Semi-flush mount dimmable LED
pendant light provided by Ownder.
(Gilt LED pendant by Modern Forms).
L13 - Wall mounted sconce provided
by Owner. (Anemone Wall Light by
Robert Abbey).
L14 - Linear wall washer, 12' long.
L3 - Unassigned
3
2'-0"x2'-0" suspended acoustical grid
ceiling.
EL
D/T
A/V
D
3
OS
Building single pole light
switch.
Building light switch w/ dimmer.
Building three-way switch.
Building occupancy sensor
Ceiling mounted electrical junction
box with outlet box as specified.
Ceiling mounted data outlet
Ceiling mounted A/V outlet
Building standard exit light fixture.
Indicates directional arrow.
Indicates illuminated face.
J
J
J
Indicates mounting height A.F.F. to
centerline of fixture.
+XX"
3
Elsy Studios
1745 Wazee Street, Suite 2D
Denver, Colorado 80202
303.479.4952
ISSUE DATE ISSUE
SHEET NUMBER
DESCRIPTION
PROJECT
BUILDING
PROJECT MANAGER
GENERAL INFORMATION
ARCHITECT
ENGINEER
FILE NAME:
TOWN APPROVAL
C:\Users\nathan.ELSYSTUDIOS\Documents\Inspirato_nathan.rvt
INSPIRATO - MEMBER LOUNGE
141 EAST MEADOW DRIVE,
STE 204
VAIL, CO 81657
SARAH ZALES
OCTOBER 27, 2014 PERMIT DRAWINGS
141 EAST MEADOW DRIVE,
STE 204
VAIL, CO 81657
ID-105
REFLECTED CEILING PLAN
1410.01
INSPIRATO - MEMBER LOUNGE
NOVEMBER 12, 2014 BAR EQUIPMENT AND GENERAL
DESIGN UPDATES
NOVEMBER 12, 2014 BUILDING DEPARTMENT
RESPONSE
NOVEMBER 20, 2014 CONSTRUCTABILITY
COORDINATION
NORTH
REFLECTED CEILING PLAN
1/4" = 1'-0"
1
2
3
12.1.2014
12/17/14