HomeMy WebLinkAbout14103 West Vail Lodge Holiday Inn Heat trace power E10 (2).pdfPROJECT: WEST VAIL LODGE HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 100A MLO TYPE: SQUARE D QO OR EQUAL AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION EXIT EGRESS LIGHTING 1000 20 1 1 2 2 30 822 HEAT TRACE ~137LF SPACE 0 3 4 822 30mA GFIC SPACE 0 5 6 2 30 1848 HEAT TRACE ~308LF SPACE 0 7 8 1848 30mA GFIC SPACE 0 9 10 2 30 1392 HEAT TRACE ~232LF BASEBOARD HEATERS 1500 30 2 11 12 1392 30mA GFIC " 1500 13 14 0 SPACE SPACE 0 15 16 0 SPACE BASEBOARD HEATERS 1000 20 2 17 18 0 SPACE " 1000 19 20 0 SPACE BASEBOARD HEATERS 1000 20 2 21 22 0 SPACE " 1000 23 24 0 SPACE 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY RECONNECT EXISTING #2 ALUMINUM FEEDER, EXIT EGRESS LIGHTING AND ELECTRIC BASEBOARD HEATER CIRCUITS SHOWN. ADD NEW HEAT TRACE CIRCUITS AS SHOWN. REST OF THE CIRCUITS ARE CALCULATED POWER FACTOR: TO BE DISCONNECTED AND TERMINATED ABOVE THE CEILING. 0.86 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 1000 5 1250 6 RECEPTACLES 0 0 0 0 MECHANICAL 15124 86 16048 91 KITCHEN 0 0 0 0 TOTAL 16124 90 17298 97 PANEL T3 NEW PROJECT: WEST VAIL LODGE HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 100A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION PHONE RECEPTACLE 900 20 1 1 2 1 20 900 RECEPTACLES OFFICE RECEPTACLE 900 20 1 3 4 1 20 900 UNIDENTIFIED FILE ROOM RECEPTACLE 900 20 1 5 6 1 20 900 UNIDENTIFIED LIGHTS 1000 20 1 7 8 1 20 900 RECEPTACLES LIGHTS 1000 20 1 9 10 1 20 900 RECEPTACLES BASEBOARD HEATERS 1500 30 2 11 12 1 20 1000 LIGHTS " 1500 13 14 1 20 1000 UNIDENTIFIED LIGHTS 1000 20 1 15 16 1 15 1000 UNIDENTIFIED BASEBOARD HEATERS 1000 20 2 17 18 1 15 1000 UNIDENTIFIED " 1000 19 20 1 20 900 RECEPTACLES BASEBOARD HEATERS 1000 20 2 21 22 1 20 900 RECEPTACLES " 1000 23 24 1 20 900 RECEPTACLES 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY DEMO CIRCUITS PER NEW PANEL SCHEDULE CALCULATED POWER FACTOR: 0.93 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 4000 19 5000 24 RECEPTACLES 9900 48 9900 48 MECHANICAL 10000 57 10750 61 KITCHEN 0 0 0 0 TOTAL 23900 123 25650 132 PANEL T3 ORIGINAL PROJECT: WEST VAIL LODGE - HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 3P, 4W MOUNTING: EXISTING MAINS: 200A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION CONDENSING UNIT 402 1456 20 2 1 2 2 20 1456 CONDENSING UNIT 422 " 1456 3 4 1456 " CONDENSING UNIT 406 1456 20 2 5 6 2 20 1456 CONDENSING UNIT 426 " 1456 7 8 1456 " CONDENSING UNIT 410 1456 20 2 9 10 2 20 1456 CONDENSING UNIT 430 " 1456 11 12 1456 " CONDENSING UNIT 414 1456 20 2 13 14 2 20 1456 CONDENSING UNIT 434 " 1456 15 16 1456 " CONDENSING UNIT 418 1456 20 2 17 18 2 20 1456 CONDENSING UNIT 438 " 1456 19 20 1456 " SPACE 0 21 22 2 30 882 HEAT TRACE ~147LF SPACE 0 23 24 882 30mA GFIC SPACE 0 25 26 2 30 912 HEAT TRACE ~152LF SPACE 0 27 28 912 30mA GFIC SPACE 0 29 30 2 30 1452 HEAT TRACE ~242LF SPACE 0 31 32 1452 30mA GFIC SPACE 0 33 34 0 SPACE SPACE 0 35 36 0 SPACE SPACE 0 37 38 0 SPACE SPACE 0 39 40 0 SPACE SPACE 0 41 42 0 SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.85 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 0 0 0 0 RECEPTACLES 0 0 0 0 MECHANICAL 35612 99 36340 101 KITCHEN RE Table 220.55 0 0 0 0 TOTAL 35612 99 36340 101 PANEL AC4A 12/09/14