Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
14103 West Vail Lodge Holiday Inn Heat trace power E10 (2).pdf
PROJECT: WEST VAIL LODGE HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 100A MLO TYPE: SQUARE D QO OR EQUAL AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION EXIT EGRESS LIGHTING 1000 20 1 1 2 2 30 822 HEAT TRACE ~137LF SPACE 0 3 4 822 30mA GFIC SPACE 0 5 6 2 30 1848 HEAT TRACE ~308LF SPACE 0 7 8 1848 30mA GFIC SPACE 0 9 10 2 30 1392 HEAT TRACE ~232LF BASEBOARD HEATERS 1500 30 2 11 12 1392 30mA GFIC " 1500 13 14 0 SPACE SPACE 0 15 16 0 SPACE BASEBOARD HEATERS 1000 20 2 17 18 0 SPACE " 1000 19 20 0 SPACE BASEBOARD HEATERS 1000 20 2 21 22 0 SPACE " 1000 23 24 0 SPACE 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY RECONNECT EXISTING #2 ALUMINUM FEEDER, EXIT EGRESS LIGHTING AND ELECTRIC BASEBOARD HEATER CIRCUITS SHOWN. ADD NEW HEAT TRACE CIRCUITS AS SHOWN. REST OF THE CIRCUITS ARE CALCULATED POWER FACTOR: TO BE DISCONNECTED AND TERMINATED ABOVE THE CEILING. 0.86 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 1000 5 1250 6 RECEPTACLES 0 0 0 0 MECHANICAL 15124 86 16048 91 KITCHEN 0 0 0 0 TOTAL 16124 90 17298 97 PANEL T3 NEW PROJECT: WEST VAIL LODGE HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 1P, 3W MOUNTING: SURFACE MAINS: 100A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B BKR P CIR CIR P BKR A B DESCRIPTION PHONE RECEPTACLE 900 20 1 1 2 1 20 900 RECEPTACLES OFFICE RECEPTACLE 900 20 1 3 4 1 20 900 UNIDENTIFIED FILE ROOM RECEPTACLE 900 20 1 5 6 1 20 900 UNIDENTIFIED LIGHTS 1000 20 1 7 8 1 20 900 RECEPTACLES LIGHTS 1000 20 1 9 10 1 20 900 RECEPTACLES BASEBOARD HEATERS 1500 30 2 11 12 1 20 1000 LIGHTS " 1500 13 14 1 20 1000 UNIDENTIFIED LIGHTS 1000 20 1 15 16 1 15 1000 UNIDENTIFIED BASEBOARD HEATERS 1000 20 2 17 18 1 15 1000 UNIDENTIFIED " 1000 19 20 1 20 900 RECEPTACLES BASEBOARD HEATERS 1000 20 2 21 22 1 20 900 RECEPTACLES " 1000 23 24 1 20 900 RECEPTACLES 0 25 26 0 0 27 28 0 0 29 30 0 0 31 32 0 0 33 34 0 0 35 36 0 0 37 38 0 0 39 40 0 0 41 42 0 LOAD CALCULATION SUMMARY DEMO CIRCUITS PER NEW PANEL SCHEDULE CALCULATED POWER FACTOR: 0.93 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 4000 19 5000 24 RECEPTACLES 9900 48 9900 48 MECHANICAL 10000 57 10750 61 KITCHEN 0 0 0 0 TOTAL 23900 123 25650 132 PANEL T3 ORIGINAL PROJECT: WEST VAIL LODGE - HOLIDAY INN HEAT TRACE ENGINEER: SOH PROJECT #: 14103 VOLTAGE: 120/208V, 3P, 4W MOUNTING: EXISTING MAINS: 200A MLO TYPE: EXISTING AIC: 10K PHASE PHASE DESCRIPTION A B C BKR P CIR CIR P BKR A B C DESCRIPTION CONDENSING UNIT 402 1456 20 2 1 2 2 20 1456 CONDENSING UNIT 422 " 1456 3 4 1456 " CONDENSING UNIT 406 1456 20 2 5 6 2 20 1456 CONDENSING UNIT 426 " 1456 7 8 1456 " CONDENSING UNIT 410 1456 20 2 9 10 2 20 1456 CONDENSING UNIT 430 " 1456 11 12 1456 " CONDENSING UNIT 414 1456 20 2 13 14 2 20 1456 CONDENSING UNIT 434 " 1456 15 16 1456 " CONDENSING UNIT 418 1456 20 2 17 18 2 20 1456 CONDENSING UNIT 438 " 1456 19 20 1456 " SPACE 0 21 22 2 30 882 HEAT TRACE ~147LF SPACE 0 23 24 882 30mA GFIC SPACE 0 25 26 2 30 912 HEAT TRACE ~152LF SPACE 0 27 28 912 30mA GFIC SPACE 0 29 30 2 30 1452 HEAT TRACE ~242LF SPACE 0 31 32 1452 30mA GFIC SPACE 0 33 34 0 SPACE SPACE 0 35 36 0 SPACE SPACE 0 37 38 0 SPACE SPACE 0 39 40 0 SPACE SPACE 0 41 42 0 SPACE LOAD CALCULATION SUMMARY CALCULATED POWER FACTOR: 0.85 CONNECTED LOAD CONNECTED AMPS DEMAND LOAD DEMAND AMPS LIGHTING/CONTINUOUS 0 0 0 0 RECEPTACLES 0 0 0 0 MECHANICAL 35612 99 36340 101 KITCHEN RE Table 220.55 0 0 0 0 TOTAL 35612 99 36340 101 PANEL AC4A 12/09/14