Loading...
HomeMy WebLinkAboutB14-0467 final inspection.pdf11-06-2015 4:04 pm A/P/D Information lnspectio!1 Re~ue!!t Reporting C!?-ru l .. :-v:---r! Vail, CO -City O_ ~t:::t ~ ~ ~ Requested Inspect Date: Mondayt..November 09.z. ~015 Site Address: 4394 STHEAMSIDE CIH W VAIL East Side Unit B Page 8 Activity: B14-0467 Type: COMBO Const Type: Occupancy: Owner: VESTAL, DON & BECKY Sub TY.pe: ADUP Ose: R-3 Status: ISSUED lnsp Area: Applicant: CUSTOM MOUNTAIN ARCHITECTS Contractor: SHAW CONTRACTING LLC Phone: 970-453-6657 Phone: 970-418-1956 Description: Notice: Addition to south and east side of duplex. New deck. Interior work includes electrical, plumbing and mechanical. PROJECTDOX-CGODFREY Comment: Comment: emailed contracotr rev3 ready for issuance -MHAEBERLE REV2 Structurals S2 & S2/1 o routed to Projectdox -CGODFREY Comment: REV3 structural revision floor framing and foundation plan, connection details routed to PROJECTDOX - CGODFREY Comment: Comment: REV1 routed to Projectdox -CGODFREY emaied contractor revieion1 ready for pickup -MHAEBERLE Requested lnspection(s) Item: 90 BLDG-Final Requestor: SHAW CONTRACTING LLC Comments: 418-1956 Assigned To: ~ Action: ~ . Time Exp: Comment: . g stair max:f opening in stair risers Item: 190 ELEC-Final Requestor: Comments: Assigned To: Action: Comment: SHAW CONTRACTING LLC ~ Time Exp: ~mecn ryn. outlets Item: 290 PLMB-Final SH~~CTING L~:e E>P Requestor: Comments: Assigned To: Action: Item: 390 MECH-Final SHAW CONTRACTING LLC ~ Requestor: Comments: Assigned To: Action: \j" _ L ~1 Time Exp: Inspection History \ \ \~\r( (1~ Item: 120 ELEC-Rough .l)~;roled ** 06/18/15 Inspector: CC Comment: hardwire smoke at 2nd Fl bed add outlet to mech rm Item: 200 MECH-Rough **Approved** 06/18/15 Inspector: CC Comment: cancelled Requested Time: 02:00 PM Phone: 970-418-1956 Entered By: JMONDRAGON K Requested Time: 11 :30 AM Phone: 970-418-1956 Entered By: JMONDRAGON K Requested Time: 01 :00 PM Phone: 970-418-1956 Entered By: JMONDRAGON K Requested Time: 01 :30 PM Phone: 970-418-1956 Entered By: JMONDRAGON K Action: PA PARTIAL APPROVAL Action: NO NOTIFIED 09/16/15 Inspector: JAM Action: Comment: fireJ?lace flue anchor flue pipe at exterior AP APPROVED Item: 220 PLMB-Rough/D.W .V. **Approved** 06/18/15 Inspector: CC Action: Comment: AP APPROVED 07/02/15 lnsP.ector: sgremmer Action: Comment: under floor Pl PARTIAL INSPECTION 11 /05/15 Inspector: sgremmer Comment: Item: 230 PLMB-Rough/Water **Approved** 06/18/15 Inspector: CC REPT131 Action: AP APPROVED Action: AP APPROVED Run Id: 14939