Loading...
HomeMy WebLinkAboutA101.1.pdfUP DN REF. REF. 1 2 3 4 A B C D E F G H TV COAT ROD & SHELF INFILL WINDOW INFILL WINDOW INFILL WINDOW INFILL WINDOWS SIGNAGE (8'-0" ABOVE) TV RESIN PANELS EXAM 1 102 EXAM 2 103 EXAM 3 104 EXAM 4 105 EXAM 5 107 EXAM 6 108 EXAM 7 109 PROCEDURE 106 LCKRS. 123 REC. 126 CLIN. MGR. 131 ADA TLT. 129 UNDERCOUNTER FREEZER LAB 130 SPECIMEN PASS-THRU FLOW STN. 101 WEIGH STATION 127 MEDS CORRIDOR 119 STRG. CAB. 124 WAITING 122 FLOAT 132 ALCOVE 125 ALCOVE 113 SOILED HOLDING 115 HSKP. 118 SUPPLY CLOSET 116 CMM IT 117 ULTRASOUND CART CART SCALE BABY SCALE COPIER 5'-0" 5'-0" CONFERENCE 100 OTOSCOPE 2'-1" TYPICAL EXAM ROOM CONFIGURATION HIGH WINDOW 11'-2 1/4" 4'-2" 10'-0" A602.1 A602.1 A602.1 35 A602.1 5 A602.1 6 A602.1 7 A602.1 2 A602.1 12 A602.1 10 A602.1 22 A602.124 A602.1 8 A602.19 A602.1 14 A602.1 16 A602.1 15 A602.118 A602.1 19 A602.1 21 A602.1 20 A602.1 31 A602.1 30 A602.1 11 A602.1 1 A602.1 3 A602.1 4 A602.1 17 A602.126 A602.1 27 8'-0" 6'-4" 2'-0" 8'-10" 17'-0 1/2" 8'-11" 2'-8" 5'-9 1/2" 3'-1" 7'-6 3/4" 17'-6" 9'-3" 11'-0" 18'-6 1/2" 14'-4" 7'-6" 8'-8 1/4" 7'-1 1/4" 2'-11" 5'-0" 4'-11 3/4" 3'-0" 4'-0 1/2" 9'-4 1/2" 5'-7 1/2" 4'-0 1/2" 11'-9 1/2" 5'-2" 1'-8" 2'-3" 3'-6" 3'-0" 5'-6 1/4" 10'-1" 5'-7 1/2" HOLD 1'-6" HOLD 1'-6" 4'-8" 7 1/2" 2'-4 1/2" 3'-6" 5'-0" 10'-1" 9'-11" 8'-6" 3'-2" EXTENT OF PROJECT C B B 100 102 103 104 105 106 107 108 109 3'-0" 118 142 130 122C 122B 122A A403.1 1 1'-9 1/2" 10'-1" INFILL DOOR 1. 1. 1. 1. 2. 1. WORK 133 14'-4" 16'-0 1/2" B H G 2'-6" 5'-0" 2'-10" 2'-6" 4'-0" MTL. STORAGE SHELVES BY OWNER FURRING WALL 141 10'-6" 5'-0" 3'-0" 1'-6" 6'-9 1/2" 5'-0" 7'-1" 2'-0" 25 RECESSED ULTRASONIC AUTOCLAVE 10'-9 3/4" 6'-1 1/2" 5'-2 3/4" SUPPLY CLOSET 140 EXISTING ELEC / IT CLOSET x100 B OFFICE 135 OFFICE 139 CLOSET 141 CHANGING 144 CONTROL 143 CART CART 5'-0" 5'-0" 129 157 116 5'-5" 11'-6 3/4" 5'-5" HOLD 5'-1" 12'-11" HOLD 5'-1" 11'-11" 12'-0" 10'-0 3/4" 5'-0" 6'-10 1/2" 10'-4 1/2" HOLD 1'-6" HOLD 1'-6" HOLD 1'-6" HOLD 1'-6" HOLD 1'-6" 9'-0" 7'-2" 6'-0"2'-9 1/2" 5'-1 3/4" 4'-6" CLOSET 137 HOLD 1'-0" 2'-0" 5'-5" 6'-5 3/4" 18'-7 3/4" FLOW STN. 134 4'-0" 9'-0" 9'-0" OFFICE 136 OFFICE 140.2 CLOSET 138 3'-6" 5'-0" 7'-6" 8'-8" 1'-0" LEADED GLASS SUBWAIT 146 VIF 16'-11 1/2" 11'-2 1/2" 16'-7 1/4" 7'-0" A403.3 2 135 136 139 140.2 137 EQ EQ 6. 5.A 144 117 138 140 VIF 3'-9" MULLION MATE 3. MULLION MATE 3. 3 A403.3 HOLD 1'-6" A602.1 37 3'-1" VIF 13'-9 1/4" 135.00° 10'-6" 6'-6 1/4" 9'-3" 3'-6" 28 FLOW STN 147 ALIGN 3'-6" 5'-7 1/2" ALIGN SAP WALL PANEL W/ MULLION EXISTING 'X-BRACE' AND BALLOON FRAMING TO REMAIN PLAM MODESTY PANEL FROM WINDOW SILL TO 2" ABOVE COUNTERTOP, FINISH BACKSIDE 1'-10" 1'-10" 1'-8" 2'-1" 2'-3" 3'-2" 36 5'-5" 1'-6" 1'-2" X-RAY 142 5'-6" 135.00° 1'-3" 4'-0" 1'-4" NEW 135 DEG. SWING DOORS, FULL-POWERED IN ACCORDANCE WITH 2012 IBC SECTION 1008.1.4.2, RE ATTACHED ELEVATION ASI #5.1 MODIFY DOOR TO RECEIVE NEW ELECTRONIC HARDWARE NEW AUTOMATIC DOOR OPERATORS NEW AUTOMATIC DOOR OPERATOR NEW AUTOMATIC DOOR OPERATOR, WIRELESS EXISTING GUARDRAIL MIN. CLEAR 3'-2 1/2" NEW AUTOMATIC DOOR OPERATOR, WIRELESS REPAIR DAMAGED SECTION OF STOREFRONT 5'-0" 5'-0"5'-0"GENERAL NOTES: 1. ALL DIMENSIONS ARE GIVEN TO FINISHED FACE OF SURFACES, CENTERLINES OF DOUBLE DOORS, INTERIOR WINDOWS AND FIXTURES, OR HINGE SIDE OF SINGLE DOORS, U.O.N. 2. WHEN TWO DIFFERENT PARTITION TYPES APPEAR ADJACENT TO EACH OTHER, THEIR FINISHED WALL SURFACES MUST ALIGN UNLESS OTHERWISE NOTED. 3. PARTITION TYPE DESIGNATION SHALL BE CONTINUOUS UNTIL NOTED OTHERWISE; CHANGES OCCUR AT WALL INTERSECTIONS AND/ORSTRUCTURAL ELEMENTS. 4. A - B DENOTES PARTITION TYPE. REFER TO SHEETS A-603 5. WHERE A RATED PARTITION IS INDICATED AND WHERE A RATING HAS BEEN GIVEN TO A FLOOR/DECK ALL PENETRATIONS MUST BE PROPERLY FIRE/SMOKE SEALED WITH A U.L. RATED FIRE STOPPING ASSEMBLY PER THE ASSIGNED RATING REQUIREMENTS. 6. AT ALL COLUMNS SHOWN FURRED OUT, USE PARTITION TYPE C-- UNLESS OTHERWISE NOTED. 7. FOR CURVED/ARCHED WALLS PROVIDE STUD FRAMING PER UNITED STATES GYPSUM (USG) RECOMMENDATIONS PER GYPSUM BOARD THICKNESS. 9. REFER TO "FIRE RESISTANCE DESIGN MANUAL," LATEST EDITION PUBLISHED BY THE GYPSUM ASSOCIATION FOR ADDITIONAL INFORMATION. THE DESIGN MANUAL'S GENERAL EXPLANATORY NOTES PERMIT MODIFICATIONS AND SUBSTITUTIONS WITHOUT DEGRADING THE FIRE RESISTANT RATING, RESULTING FROM INCREASING STUD DEPTHS, STUD GAUGES, WALLBOARD THICKNESS, NUMBER OF LAYERS, AND CHASE WALL DIMENSIONS. 10. AT ALL STRUCTURAL STUD FRAMED EXTERIOR WALL CONDITIONS, INTERIOR FINISH GYP BD (5/8" TYPE "X") SHALL EXTEND CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE AT ALL LEVELS. 11. MEET OR EXCEED THE PARTITION TYPE REQUIREMENTS INDICATED. 12. USE DIRECT ATTACHED SYSTEMS FOR UL TESTED FIRE RATED WALLBOARD SYSTEMS. 13. REFER TO THE LIFE SAFETY PLANS AND FLOOR PLANS (A SERIES SHEETS) FOR PARTITION TYPE LOCATIONS. ALL NEW WALLS TO BE TYPE A - A UNLESS OTHERWISE NOTED. 14. WATER RESISTANT GYPSUM BOARD SHALL BE USED IN LIEU OF STANDARD GYPSUM BOARD AT WALLS WITH TILE OR STONE VENEER FINISH. AT WET WALLS USE CEMENTITIOUS BACKER IN LIEU OF STANDARD GYPSUM BOARD. 15. SEE SPECIFIC DETAIL DRAWINGS AND SPECIFICATIONS FOR OFFSET ATTHE TOP OF THE PARTITION, PLAN CONFIGURATIONS AND PROJECT CONDITIONS. 16. PROVIDE BLOCKING AND SUPPORT FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES. 17. AT ALL PARTITION TYPES WHERE THE GYPSUM BOARD DOES NOT EXTENDTO STRUCTURE ABOVE PROVIDE 20 GA STUD DIAGONAL BRACING ON ALTERNATE SIDES OF PARTITION TO STRUCTURE AT 72" O.C. MAXIMUM. 18. AT ALL DOOR FRAMES AND CASED OPENINGS 48" WIDE OR LESS PROVIDE (2) 20 GA STUDS FULL HEIGHT TO STRUCTURE EACH SIDE. AT ALL DOOR FRAMES AND CASED OPENINGS LARGER THAN 48" WIDE AND ALL LEAD LINED DOORS PROVIDE (2) 16 GA STUDS EACHSIDE WITH 16 GA FRAMED BOX HEADER. FLOOR PLAN KEY NOTES: 1. INFILL EXISTING WINDOW ON INTERIOR SIDE; PROVIDE FRAMING, INSULATION, GYPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. REPLACE EXISTING GLASS WITH SPANDREL GLASS, PROVIDE COLOR FOR SELECTION BY ARCHITECT. 2. DEMO DOOR, INFILL OPENING TO MATCH EXISTING ADJACENT WALL ASSEMBLY. PROVIDE FRAMING, INSULATION, GUPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. MATCHEXISTING EXTERIOR FINISH. 3. INFILL VOID BETWEEN GLASS AND END OF WALL, INSTALL 'MULLION MATE PARTITION CLOSURES', RE SPECIFICATIONS 4. INFILL OPENING, PROVIDE FRAMING, INSULATION, GYPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. MATCH EXISTING EXTERIOR FINISH. 8. REFER TO FFE00 FOR LOCATION OF WINDOW SHADES/COVERING, CORNER GUARD, WALL BASE LOCATION. 5. EXISTING WALLS TO REMAIN THAT HAVE 'ORANGE PEEL' OR 'TEXTURED' WALL FINISH SHALL RECEIVE 'LEVEL 4' DRYWALL SKIM FINISH. 6. REFER TO SHEET A403.3, ENLARGED DETAILS FOR LEAD SHIELDING IN THIS ROOM. 7. INFILL OPENINGS 000 4' 8' 16' SCALE: 000 2' 4' 8' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/4" = 1'-0" 1/8" = 1'-0" 6/15/2015 3:40:22 PM A101.1 Checker Author ARCHITECTURAL FLOOR PLAN - LEVEL 1 DECEMBER 15, 2014 CONSTRUCTION DOCUMENTS VVMC MEDICAL PROFESSIONAL BUILDING COMMERCIAL TENANT IMPROVEMENT, INTERIOR REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 13026.07 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 1/4" = 1'-0" 1 SCHEMATIC FLOOR PLAN - LEVEL ONE 1 Addendum 1 12/23/14 3 Addendum 4 3/13/15 5 Addendum 5 4/06/15 8 ASI 4 5/18/15 9 ASI 5 6/15/15 1 3 3 5 8 9 9 07/16/15