Loading...
HomeMy WebLinkAboutA101.2.pdfUP UP REF. DN UP TV TV 1 2 3 4 A B C D E F G H A602.2 18 A602.217 A602.215 A602.2 16 A602.2 1 A602.2 2 A602.2 12 A602.213 A602.2 14 A602.2 11 A602.2 3 A602.2 4 A602.2 5 A602.2 6 A602.2 8 A602.2 7 A602.2 9 A602.2 10 SERVER ROOM 212 IT DIRECTOR'S OFFICE 208 IT OFFICE 209 HR OFFICE 210 IT STAFF WORK AREA 207 RECEPTION 217 WAITING 218 PT TLT / LOCKERS 200 STAFF WORK ROOM 215 EXERCISE AREA 201 PRIVATE TREATMENT 206 ORTH. FAB. & SUPPLIES STORAGE 205 STAFF LOUNGE 216 TREATMENT AREA 204 7'-9 1/4" 13'-2 1/2" 4'-4 1/4" LINEN DROP TRASH DROP STANDING HT. CTR. (42") SIGNAGE SIGNAGE 22'-10 1/2" 5'-0" STAFF WORK 203 PERFORMANCE AREA 202 WAITING 213 BLOCKING IN WALL FOR EQUIPMENT ALIGN WALL WITH WINDOW OPENING 3'-0" 6'-1" WALL MTD TV WALL MTD TV CUBICLE CURTAIN TRACK PRINTER / COPIER 214 A602.2 40 39 HR OFFICE 211 9'-10 1/2" 11'-8 1/4" 10'-10 1/2" 1" 6'-4 1/4" 7'-4 3/4" 9'-5" 10'-7 3/4" 5'-3 3/4" 12'-6" 7'-1" 3'-11 1/4" 8'-3" 9'-8" 3'-11 1/4" 12'-9 1/4" 19'-0" 1'-9 1/2" 9'-6" 11 3/4" 4'-2 1/4" 3'-9 1/2" 4'-3 3/4" 3'-9 1/2" 4'-3 3/4" 3'-9 1/2" 6'-5 3/4" 7'-9 1/4" 4'-0" 32'-3 3/4" 3'-9 1/2" 3'-10" 7'-0" 16'-7 3/4" 4'-0" 2'-0" 2'-0" 2'-8" 2'-5" 2'-0" 2'-0" 2'-0" 2'-10" 5'-0" 4'-6" 2'-0" 12'-0 1/2" 11'-0 1/4" 12'-5 1/4" 9'-8 1/4" 12'-7" EXTENT OF PROJECT F E A602.2 19 20 200 218 216A 206 205 212 211 210 214 207 216B WATER DISPENSER 213 A602.2 21 5'-3 3/4" ALIGN +72 +72 +72 +72 ICEMAKER BELOW COUNTER UNDERCOUNTER REFRIGERATOR DRINKING WATER DISPENSER BY OWNER CLOSET 219 1'-7" 219 3'-6" 3'-6" CLOSET 220 10" HOT WATER HEATER RE: PLUMBING 3. MULLION MATE 3. MULLION MATE 3. MULLION MATE G G 1'-4" 5. 5. 5. 5. 5. ALIGN 3'-5" 220 12 A402 Sim ADA COMPLIANT FOLD-DOWN DRESSING BENCH, 42"X20", ACCESS-ABLE DESIGNS, #D-101-42, OR APPROVED EQUAL GENERAL NOTES: 1. ALL DIMENSIONS ARE GIVEN TO FINISHED FACE OF SURFACES, CENTERLINES OF DOUBLE DOORS, INTERIOR WINDOWS AND FIXTURES, OR HINGE SIDE OF SINGLE DOORS, U.O.N. 2. WHEN TWO DIFFERENT PARTITION TYPES APPEAR ADJACENT TO EACH OTHER, THEIR FINISHED WALL SURFACES MUST ALIGN UNLESS OTHERWISE NOTED. 3. PARTITION TYPE DESIGNATION SHALL BE CONTINUOUS UNTIL NOTED OTHERWISE; CHANGES OCCUR AT WALL INTERSECTIONS AND/ORSTRUCTURAL ELEMENTS. 4. A - B DENOTES PARTITION TYPE. REFER TO SHEETS A-603 5. WHERE A RATED PARTITION IS INDICATED AND WHERE A RATING HAS BEEN GIVEN TO A FLOOR/DECK ALL PENETRATIONS MUST BE PROPERLY FIRE/SMOKE SEALED WITH A U.L. RATED FIRE STOPPING ASSEMBLY PER THE ASSIGNED RATING REQUIREMENTS. 6. AT ALL COLUMNS SHOWN FURRED OUT, USE PARTITION TYPE C-- UNLESS OTHERWISE NOTED. 7. FOR CURVED/ARCHED WALLS PROVIDE STUD FRAMING PER UNITED STATES GYPSUM (USG) RECOMMENDATIONS PER GYPSUM BOARD THICKNESS. 9. REFER TO "FIRE RESISTANCE DESIGN MANUAL," LATEST EDITION PUBLISHED BY THE GYPSUM ASSOCIATION FOR ADDITIONAL INFORMATION. THE DESIGN MANUAL'S GENERAL EXPLANATORY NOTES PERMIT MODIFICATIONS AND SUBSTITUTIONS WITHOUT DEGRADING THE FIRE RESISTANT RATING, RESULTING FROM INCREASING STUD DEPTHS, STUD GAUGES, WALLBOARD THICKNESS, NUMBER OF LAYERS, AND CHASE WALL DIMENSIONS. 10. AT ALL STRUCTURAL STUD FRAMED EXTERIOR WALL CONDITIONS, INTERIOR FINISH GYP BD (5/8" TYPE "X") SHALL EXTEND CONTINUOUS FROM FLOOR TO STRUCTURE ABOVE AT ALL LEVELS. 11. MEET OR EXCEED THE PARTITION TYPE REQUIREMENTS INDICATED. 12. USE DIRECT ATTACHED SYSTEMS FOR UL TESTED FIRE RATED WALLBOARD SYSTEMS. 13. REFER TO THE LIFE SAFETY PLANS AND FLOOR PLANS (A SERIES SHEETS) FOR PARTITION TYPE LOCATIONS. ALL NEW WALLS TO BE TYPE A - A UNLESS OTHERWISE NOTED. 14. WATER RESISTANT GYPSUM BOARD SHALL BE USED IN LIEU OF STANDARD GYPSUM BOARD AT WALLS WITH TILE OR STONE VENEER FINISH. AT WET WALLS USE CEMENTITIOUS BACKER IN LIEU OF STANDARD GYPSUM BOARD. 15. SEE SPECIFIC DETAIL DRAWINGS AND SPECIFICATIONS FOR OFFSET ATTHE TOP OF THE PARTITION, PLAN CONFIGURATIONS AND PROJECT CONDITIONS. 16. PROVIDE BLOCKING AND SUPPORT FOR ALL WALL MOUNTED EQUIPMENT AND ACCESSORIES. 17. AT ALL PARTITION TYPES WHERE THE GYPSUM BOARD DOES NOT EXTENDTO STRUCTURE ABOVE PROVIDE 20 GA STUD DIAGONAL BRACING ON ALTERNATE SIDES OF PARTITION TO STRUCTURE AT 72" O.C. MAXIMUM. 18. AT ALL DOOR FRAMES AND CASED OPENINGS 48" WIDE OR LESS PROVIDE (2) 20 GA STUDS FULL HEIGHT TO STRUCTURE EACH SIDE. AT ALL DOOR FRAMES AND CASED OPENINGS LARGER THAN 48" WIDE AND ALL LEAD LINED DOORS PROVIDE (2) 16 GA STUDS EACHSIDE WITH 16 GA FRAMED BOX HEADER. FLOOR PLAN KEY NOTES: 1. INFILL EXISTING WINDOW ON INTERIOR SIDE; PROVIDE FRAMING, INSULATION, GYPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. REPLACE EXISTING GLASS WITH SPANDREL GLASS, PROVIDE COLOR FOR SELECTION BY ARCHITECT. 2. DEMO DOOR, INFILL OPENING TO MATCH EXISTING ADJACENT WALL ASSEMBLY. PROVIDE FRAMING, INSULATION, GUPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. MATCHEXISTING EXTERIOR FINISH. 3. INFILL VOID BETWEEN GLASS AND END OF WALL, INSTALL 'MULLION MATE PARTITION CLOSURES', RE SPECIFICATIONS 4. INFILL OPENING, PROVIDE FRAMING, INSULATION, GYPSUM WALL BOARD, AND FINISH FLUSH WITH EXISTING INTERIOR WALL. MATCH EXISTING EXTERIOR FINISH. 8. REFER TO FFE00 FOR LOCATION OF WINDOW SHADES/COVERING, CORNER GUARD, WALL BASE LOCATION. 5. EXISTING WALLS TO REMAIN THAT HAVE 'ORANGE PEEL' OR 'TEXTURED' WALL FINISH SHALL RECEIVE 'LEVEL 4' DRYWALL SKIM FINISH. 00 0 4' 8' 16' SCALE: 00 0 2' 4' 8' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/4" = 1'-0" 1/8" = 1'-0" 1/12/2015 7:44:30 PM A101.2 Checker Author ARCHITECTURAL FLOOR PLAN -LEVEL 2 DECEMBER 15, 2014 CONSTRUCTION DOCUMENTS VVMC MEDICAL PROFESSIONAL BUILDING COMMERCIAL TENANT IMPROVEMENT, INTERIOR REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 13026.07 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 1/4" = 1'-0" 1 FLOOR PLAN - LEVEL 2 1 Per Bldg. Dept 1/8/2015 1 01/16/15