Loading...
HomeMy WebLinkAboutA400.3.pdfS GENERAL NOTES 1. SEPARATELY SWITCH LIGHT FIXTURES AT ALL EXAMS AND OFFICES. 2. REPLACE ALL DAMAGES AND/OR DIRTY CEILING TILES, MATCH EXISTING 3. U.O.N CENTER GA OFFICE 315 OFFICE 312 STAFF LOUNGE 310 EXAM 1 306 DR.'S OFFICE 309 EXAM 2 308 EXAM 3 307 WAITING 300 CLOSET 314 RECEPTION 301 HALLWAY 302 CLOSET 303 CLOSET 311 IT CLOSET 305 PRP 304 HALL 313 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" 8' - 0" OFFICE 316 EXTENT OF PROJECT EXTENT OF PROJECT 1 1 1 1 1 1 1 1 1 1 KEY NOTES 1. ALL CEILINGS IN THIS TENANT SPACE EXIST TO REMAIN U.O.N 2. SEE FP (NOTE 4) 4 A401 Sim OFFICE 317 REFLECTED CEILING PLAN LEGEND SUSPENDED CEILING GRID SUPPLY AIR DIFFUSER RETURN AIR DIFFUSER EXHAUST AIR DIFFUSER SPEAKER FIRE ALARM REMOTE INDICATOR LIGHT COVE LIGHTING PROCEDURE LIGHT PENDANT LIGHT FIXTURE IN CEILING COFFER RECESSED DOWN LIGHT DIRECTIONAL RECESSED DOWN LIGHT WALL SCONCE WALL MOUNTED LIGHT FIXTURE SUSPENDED LIGHT FIXTURE (DIRECT / INDIRECT) 4'-0" SUSPENDED LIGHT FIXTURE (DIRECT / INDIRECT) SUSPENDED GYPSUM BOARD CEILING, UNLESS OTHERWISE NOTED CEILING HEIGHT ABOVE FINISHED FLOOR 24" X 48" FLUORESCENT LIGHT FIXTURE FLUORESCENT UNDERCABINET TASK LIGHT FIRE ALARM DEVICE (STROBE, HORN, CHIME, OR COMBO) REFER TO ENGINEERING DRAWINGS. LIFT/ CURTAIN TRACK 12" x 48" FLUORESCENT GRID MTD RECESSED WALL WASH 2' X 4' GRID MOUNTED LIGHT FIXTURE 2' X 2' GRID MOUNTED LIGHT FIXTURE SMOKE / FLAME, OR THERMAL DETECTOR: REFER TO ENGINEERING DRAWINGS. X'-X" F S R 2x4 2x2 BREAK GRID AT LOCATION INDICATED TO ALIGN AS SHOWN BR OPEN TO STRUCTURE OTS EXIT SIGN LINEAR- STRIP WALL MOUNTED 000 4' 8' 16' SCALE: 000 2' 4' 8' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/4" = 1'-0" 1/8" = 1'-0" 3/13/2015 6:36:35 PM A400.3 Checker Author ARCHITECTURAL REFLECTED CEILNG PLAN - LEVEL 3 DECEMBER 15, 2014 CONSTRUCTION DOCUMENTS VVMC MEDICAL PROFESSIONAL BUILDING COMMERCIAL TENANT IMPROVEMENT, INTERIOR REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 13026.07 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 1/4" = 1'-0" 1 REFLECTED CEILING PLAN - LEVEL THREE 3 Addendum 4 3/13/15 3 04/15/15