Loading...
HomeMy WebLinkAboutA600.2.pdfN This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number key plan sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 3/13/2015 6:36:38 PM A600.2 Checker Author FINISH SCHEDULE DECEMBER 15, 2014 CONSTRUCTION DOCUMENTS VVMC MEDICAL PROFESSIONAL BUILDING COMMERCIAL TENANT IMPROVEMENT, INTERIOR REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 13026.07 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 ROOM FINISH SCHEDULE NUMBER NAME FLOOR FINISH BASE FINISH WALL FINISH WALL PROTECTION CEILING FINISH COMMENTS NORTH EAST SOUTH WEST 100 CONFERENCE CPT1.1 RB1 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 101 FLOW STN. CPT1.2 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 102 EXAM 1 LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.2 SUSPENDED GRID & ACOUSTICAL TILE 103 EXAM 2 LSF 1.1 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 104 EXAM 3 LSF1.1 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 105 EXAM 4 LSF1.1 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 106 PROCEDURE LSF1.1 RB2 PT1.1 PT1.1 PT1.2 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 107 EXAM 5 LSF1.1 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 108 EXAM 6 LSF1.1 RB2 PT1.1 PT1.2 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 109 EXAM 7 LSF1.1 RB2 PT1.1 PT1.2 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 110 EXAM 8 111 FLOW STN. CPT1.2 RB2 PT1.1 PT1.1 PT1.2 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 112 BACK STAGE WRK. 113 ALCOVE CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 114 ELECTRICAL EXISTING CONCRETE RB2 PT1.1 PT1.1 PT1.1 PT1.1 OPEN TO STRUCTURE 115 SOILED HOLDING LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 116 SUPPLY CLOSET LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 117 CMM IT LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 OPEN TO STRUCTURE 118 HSKP. LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 119 CORRIDOR CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 120 EXAM 9 - ULTRASOUND 121 EXAM 10 122 WAITING CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.2 SUSPENDED GRID & ACOUSTICAL TILE 123 LCKRS. CPT1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 124 STRG. CAB. CPT1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 125 ALCOVE CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 126 REC. CPT1.2 RB1 PT1.1 PT1.2 PT1.1 PT1.1 SUSPENDED GRID & TILE / GYPSUM WALL BOARD 127 WEIGH STATION CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 128 ADA TLT. 129 ADA TLT. LSF1.1 COVED PT1.1/CWT1 PT1.1/CWT1 PT1.1/CWT1 PT1.1/CWT1 GYPSUM WALL BOARD INTEGRAL COVED BASE WITH FLOORING. RE: ELEVATIONS FOR TILE HEIGHT. 130 LAB LSF1.1 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 131 CLIN. MGR. CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 132 FLOAT CPT1.1 RB1 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 133 WORK CPT1.2 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 134 FLOW STN. CPT1.2 RB2 PT1.2 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 135 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 136 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 137 CLOSET CPT2.3 RB1 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 138 CLOSET CPT2.3 RB1 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 139 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 140 SUPPLY CLOSET LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 140.2 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 141 CLOSET LSF1.1 RB2 PT1.1 PT1.1 PT1.1 PT1.1 SUSPENDED GRID & ACOUSTICAL TILE 142 X-RAY LSF1.1 RB3 PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 143 CONTROL LSF1.1 RB3 PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 144 CHANGING LSF1.1 RB3 PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 146 SUBWAIT MATCH CORRIDOR-EXISTING FLOOR FINISH MATCH EXISTING, ADJACENT FINISH MATCH EXISTING CORRIDOR MATCH EXISTING CORRIDOR MATCH EXISTING CORRIDOR MATCH EXISTING CORRIDOR MATCH EXISTING CORRIDOR 200 PT TLT / LOCKERS LSF2.1 COVED PT2.1 PT2.1 PT2.1 PT2.1 GYPSUM WALL BOARD INTEGRAL COVED BASE WITH FLOORING 201 EXERCISE AREA RBF2 RB2 PT2.2 PT2.1 PT2.2 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 202 PERFORMANCE AREA RBF1 RB2 PT2.2 PT2.1 PT2.2 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 203 STAFF WORK RBF2 RB2 N/A N/A PT2.1 PT2.4 SUSPENDED GRID & ACOUSTICAL TILE 204 TREATMENT AREA RBF2 RB2 PT2.1 PT2.1 PT2.1 N/A SUSPENDED GRID & TILE / GYPSUM WALL BOARD Walls within niche of head wall shall receive PT2.4. (Head walls (exterior face shall be PT2.1.) Soffit within niche shall be PT2.1 205 ORTH. FAB. & SUPPLIES STORAGE RBF2 RB2 PT2.1 PT2.1 PT2.1 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 206 PRIVATE TREATMENT RBF2 RB2 PT2.1 PT2.3 PT2.1 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 207 IT STAFF WORK AREA CPT2.2 RB1 PT2.3/PT2.4 PT2.3/PT2.4 PT2.3/PT2.4 PT2.3 SUSPENDED GRID & ACOUSTICAL TILE 208 IT DIRECTOR'S OFFICE CPT2.2 RB1 PT2.3 PT2.4 PT2.3 PT2.3 SUSPENDED GRID & ACOUSTICAL TILE 209 IT OFFICE CPT2.2 RB1 PT2.3 PT2.4 PT2.3 PT2.3 SUSPENDED GRID & ACOUSTICAL TILE 210 HR OFFICE CPT2.3 RB1 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 211 HR OFFICE CPT2.3 RB1 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 212 SERVER ROOM CPT2.3 RB2 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 213 WAITING CPT2.3 RB1 PT2.6 PT2.5 N/A PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 214 PRINTER / COPIER CPT2.3 RB2 PT2.5 PT2.5 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 215 STAFF WORK ROOM LSF2.1 RB2 PT2.1 PT2.1 PT2.1 PT2.3 SUSPENDED GRID & ACOUSTICAL TILE 216 STAFF LOUNGE LSF2.1 RB2 PT2.1 PT2.3 PT2.1 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 217 RECEPTION CPT2.1 RB1 PT2.1 PT2.1 PT2.1 PT2.4 SUSPENDED GRID & ACOUSTICAL TILE 218 WAITING CPT2.1 RB1 PT2.1 PT2.3 PT2.1 PT2.1 SUSPENDED GRID & ACOUSTICAL TILE 219 CLOSET CPT2.2 PT2.1 PT2.1 PT2.1 PT2.1 300 WAITING CPT3.1 EXIST. BASE PT3.1 PT3.2 PT3.1 PT3.1 SUSPENDED GRID & TILE / GYPSUM WALL BOARD 301 RECEPTION CPT3.1 EXIST. BASE PT3.2 (NW) PT3.1 PT3.1 PT3.1 SUSPENDED GRID & TILE / GYPSUM WALL BOARD 302 HALLWAY CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 303 CLOSET CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 GYPSUM WALL BOARD 304 PRP LSF3.1 RB2 PT3.1 PT3.1 PT3.2 PT3.1 GYPSUM WALL BOARD 305 IT CLOSET LSF3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 306 EXAM 1 CPT3.1 EXIST. BASE PT3.2 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 307 EXAM 3 CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.2 SUSPENDED GRID & TILE / GYPSUM WALL BOARD 308 EXAM 2 CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.2 SUSPENDED GRID & ACOUSTICAL TILE 309 DR.'S OFFICE CPT3.1 EXIST. BASE PT3.2 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 310 STAFF LOUNGE CPT3.1 EXIST. BASE PT3.2 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & TILE / GYPSUM WALL BOARD 311 CLOSET CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 312 OFFICE CPT3.1 EXIST. BASE PT3.2 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 313 HALL CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 314 CLOSET CPT3.1 EXIST. BASE PT3.1 PT3.1 PT3.1 PT3.1 GYPSUM WALL BOARD 315 OFFICE CPT3.1 EXIST. BASE PT3.2 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 316 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 317 OFFICE CPT2.3 RB1 PT2.5 PT2.6 PT2.5 PT2.5 SUSPENDED GRID & ACOUSTICAL TILE 318 CHANGING LSF3.1 RB3 PT3.1 PT3.1 PT3.1 PT3.1 SUSPENDED GRID & ACOUSTICAL TILE 319 SUBWAIT MATCH ADJACENT EXIST RB1 MATCH ADJACENT EXIST MATCH ADJACENT EXIST MATCH ADJACENT EXIST N/A x100 EXISTING ELEC / IT CLOSET EXISTING CONCRETE RB2 PT1.1 PT1.1 PT1.1 PT1.1 OPEN TO STRUCTURE 1 Addendum 1 12/23/14 3 Addendum 4 3/13/15 1 1 3 3 3 3 3 04/15/15