TYPE A PARTITION (3 5/8" STUD) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD EACH SIDE TYPE X FOR FIRE RATED PARTITIONS 3 5/8" METAL STUDS @ 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED CEILING - SEE RCP SEALANT STRUCTURAL DECK DEFLECTION TRACK 2 HR CONSTRUCTION (U.L. U411) 2 LAYERS TYPE 'X' 5/8" GYPSUM WALLBOARD EACH SIDE 1 HOUR CONSTRUCTION = U.L. U419 TYPE B PARTITION (6" STUD) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD EACH SIDE TYPE X FOR FIRE RATED PARTITIONS 6" METAL STUDS @ 16" O.C. 3 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED CEILING - SEE RCP SEALANT STRUCTURAL DECK DEFLECTION TRACK 2 HR CONSTRUCTION (U.L. U419) 2 LAYERS TYPE 'X' 5/8" GYPSUM WALLBOARD EACH SIDE 1 HOUR CONSTRUCTION = U.L. U419 TYPE C PARTITION (2 1/2" STUD) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD EACH SIDE TYPE X FOR FIRE RATED PARTITIONS 2 1/2" METAL STUDS @ 16" O.C. CEILING - SEE RCP SEALANT STRUCTURAL DECK DEFLECTION TRACK 2 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED TYPE F PARTITION (CHASE WALL) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD AT EXPOSED FACES 3 5/8" METAL STUDS @ 16" O.C. CEILING - SEE RCP SEALANT STRUCTURAL DECK DEFLECTION TRACK 1'-4" U.N.O BRACE EACH PAIR OF STUDS W/ RUNNERS @ 24" O.C VERTICALLY. 4" FIXTURE SIDE 3 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED TYPE H PARTITION SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD EACH SIDE 3 5/8" METAL STUDS @ 16" O.C. CEILING - SEE RCP STRUCTURAL DECK DEFLECTION TRACK 4" MIN 3 5/8" METAL STUD BRACING UP TO STRUCTURE @ 48" O.C.; STAGGER BRACING TYPE J PARTITION SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD , ONE SIDE ONLY 3 5/8" METAL STUDS @ 16" O.C. CEILING - SEE RCP STRUCTURAL DECK DEFLECTION TRACK 4 " MIN 3 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED UNFINISHED AT THIS SIDE TYPE K PARTITION (7/8" FURRING) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE 5/8" GYPSUM WALLBOARD 7/8" METAL FURRING CHANNELS @ 24" O.C. VERTICAL CEILING - SEE RCP STRUCTURAL DECK 4 " MIN FACE OF COLUMN OR WALL BEHIND FURRING TYPE Q PARTITION (1 5/8" FURRING) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE 5/8" GYPSUM WALLBOARD 1 5/8" METAL STUDS @ 16" O.C. OR AS REQUIRED AT COLUMN FURRING LOCATIONS CEILING - SEE RCP STRUCTURAL DECK 4 " MIN FACE OF COLUMN OR WALL BEHIND FURRING SAME GA. "CLIP" ANGLE AT 16" O.C. OR AS REQUIRED. SECURE TO COLUMN OR WALL CONDITION BEHIND TYPE E PARTITION (4" C-H STUD) SEALANT FLOORING AND BASE SEE FINISH SCHEDULE 4" STEEL 'J' RUNNER TRACK 5/8" TYPE X GYPSUM WALLBOARD 4" METAL C-H STUDS @ 24" O.C. CEILING - SEE RCP SEALANT STRUCTURAL DECK 4" STEEL 'J' RUNNER TRACK 2 1/2" SOUND ATTENUATION BLANKETS WHERE NOTED 1" GYPSUM WALLBOARD LINER PANEL 2 HR CONSTRUCTION (U.L. 417) 1 HOUR CONSTRUCTION = U.L. U417 SEALANT FLOORING AND BASE SEE FINISH SCHEDULE RUNNER TRACK 5/8" GYPSUM WALLBOARD EACH SIDE 3 5/8" 25 GA STEEL STUDS @ 12" O.C. (18 GA AT M-G LOCATIONS) CORNER BEAD RE: INTERIOR ELEVATIONS CAP RE: FINISH SCHEDULE 3"x3"x1/4" x3'-0" TUBE STEEL POST NEAR WALL ENDS AND AT 6'-0" O.C. ANCHOR TO FLOOR WIHT 3"x9"x1/4" PLATE WELDED TO POST( AT M-G LOCATIONS ONLY) TYPE M PARTITION (PARTIAL HEIGHT) FLOORING AND BASE SEE FINISH SCHEDULE NEW LEAD LINED GYPSUM WALLBOARD ON 1 SIDE OF EXISTING GYPSUM WALLBOARD ON METAL STUD WALL; TO 7'-0" MINIMUM HEIGHT; (LEAD THICKNESS PER PHYSICIST REPORT LISTING) TO UPGRADE EXISTING WALL TO SHIELDED CONDITION. SEALANT STRUCTURAL DECK EXISTING GYPSUM WALLBOARD ON METAL STUD WALL SYSTEM TYPE Y PARTITON (EXISTING) 000 4' 8' 16' SCALE: N This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number sheet title item date date issued for seal/signature consultants/construction managers owner's project number project number 1/8" = 1'-0" 12/15/2014 3:20:49 PM A603 AW LLI STANDARD PARTITION TYPES DECEMBER 15, 2014 CONSTRUCTION DOCUMENTS VVMC MEDICAL PROFESSIONAL BUILDING COMMERCIAL TENANT IMPROVEMENT, INTERIOR REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 13026.07 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 1. REFER TO THE ARCHITECTURAL FLOOR PLANS FOR PARTITION TYPE LOCATIONS AND EXTENTS. 2. REFER TO SPECIFICATIONS FOR ALTERNATIVE WALLBOARD TYPE TO BE USED IN LIEU OF GYPSUM BOARD AT WET WALLS AND ALL WALLS WITH CERAMIC TILE FINISH. 3. PROVIDE BLOCKING AND SUPPORT FOR CASEWORK, EQUIPMENT AND ACCESSORIES WHICH REQUIRE INTERNAL REINFORCEMENT ON PARTITION WALLS. REVIEW EQUIPMENT AND ACCESSORIES SHOWN ON PLANS AND INTERIOR ELEVATIONS. 4. REFER TO INTERIOR DETAILS FOR PARTITION CONFIGURATIONS AT INTERFACE WITH VARIOUS STRUCTURAL COMPONENTS. 5. GYPSUM BOARD JOINTS ARE TO BE FINISHED DOWN TO FLOOR LEVEL AND UP TO SLAB/STRUCTURAL DECK ABOVE. JOINTS ABOVE CEILINGS MAY HAVE A REDUCED LEVEL OF FINISH. 6. ALL PARTITIONS SHOWN ARE NON-BEARING. 7. WHEN CONSTRUCTING A RATED WALL, FOLLOW ALL DETAILS OF THE LISTED ASSEMBLY. NOT ALL OF THE U.L. REQUIREMENTS ARE INDICATED ON THESE DRAWING DETAILS. 8. AT FIRE RATED PARTITIONS USE FIRE RATED SEALANT AT TOP AND BOTTOM OF WALL. ACOUSTIC SEALANT SHALL BE USED AT ALL NON-FIRE RATED SOUND WALLS. 9. CONTRACTOR SHALL INCREASE STUD GAUGE AND/OR ADJUST SPACING OF STUDS IN ORDER TO MEET WALL DEFLECTION CRITERIA, FOR WALL HEIGHTS / LENGTHS. 10. REFER TO SPECIFICATIONS FOR ACCEPTABLE MANUFACTURERS AND TYPES OF DEFLECTION TRACKS TO BE USED. INSTALL PER UL TESTS WHERE PARTITIONS ARE RATED. 11. SEE FLOOR PLAN TAGS AND LIFE SAFETY PLANS FOR LOCATIONS AND EXTENTS OF FIRE-RATED AND SMOKE-SEALED PARTITIONS. 12. PARTITION TYPE DESIGNATIONS ARE CONTINUOUS ON FLOOR PLANS UNTIL TAGGED OTHERWISE; CHANGES OCCUR AT PARTITION INTERSECTIONS AND/OR STRUCTURAL ELEMENTS. 13. AT ALL DOOR FRAMES, CASED OPENINGS, AND WINDOWS, USE (2) 20 GA STUDS FULL HEIGHT TO STRUCTURE AT BOTH JAMBS. 14. PROVIDE UL APPROVED ASSEMBLIES FOR PENETRATIONS AT FIRE-RATED PARTITIONS. 15. PROVIDE SEALANT AND/OR MINERAL WOOL FIRE-SAFEING FOR GAPS AT SMOKE-SEALED PARTITIONS. 16. LABEL ALL FIRE-RATED AND SMOKE-SEALED PARTITIONS ABOVE FINISHED CEILINGS PER SPECIFICATION REQUIREMENTS. 17. SOUND ATTENUATION BLANKETS SHALL BE COMPATIBLE WITH U.L. DESIGN NUMBERS. 18. ALL NEW PARTITIONS TO BE TYPE A-A (FULL HEIGHT, UNRATED, AND SOUND INSULATED); U.N.O. 19. ALL GYPSUM BOARD SHALL BE 5/8" THICK; TYPE 'X' AS INDICATED IN WALL TAG. PARTITION TYPE NOTES - NON RATED # HOUR RATING N2G PARTITION TYPE I.D. LETTER - NO SPECIAL FEATURES A SOUND INSULATED B LEAD LINED AS SPECIFIED C LEAD LINED AND SOUND INSULATED (1/16" LEAD SHIELDING) D SOUND INSULATED WITH VAPOR BARRIER E THERMALLY INSULATED WITH VAPOR BARRIER G ANCHORED STEEL POSTS WITHIN LOW WALL H STONE VENEER J 20 GAUGE STUDS S SPECIAL WALL SYSTEMS; SEE ROOM DETAILS/SECTIONS PARTITION TYPE KEY SEE SHEETS A101.A-C FOR PARTITION TYPE TAGS NOTE: REFER TO LIFE SAFETY PLANS FOR INDICATION OF PARTITIONS REQUIRING SMOKE RESISTANCE. 1 01/16/15