Loading...
The URL can be used to link to this page
Your browser does not support the video tag.
Home
My WebLink
About
B14-0477 Balance Report.pdf
TEST, ADJUST AND BALANCE REPORT PROJECT VVMC MEDICAL PROFESSIONAL BLDG 1ST FLOOR #1162 PREPARED FOR FALCON PLUMBING AND HEATING REPORT ISSUE DATE 7/9/2015 PREPARED BY HVAC TAB llc P.O. BOX 1926 VAIL, CO 81658 PHONE: 970-376-5198 E-MAIL: mrichardson@hvactab.co HVAC TAB llc DATE: 7/6/2015 INSTRUMENT CALIBRATION REPORT PROJECT : VVMC MEDICAL PROFESSIONS BLDG PROJECT ALTITUDE: 22.5 “HG INSTRUMENT/ SERIAL # APPLICATION DATE OF USE CALIBRATION DATE CALIBRATION DUE DATE SHORTRIDGE ADM-870C / #M00483 AIR FLOW READINGS 7/6/2015 06/08/2015 06/08/2016 ANEMOMETER #T57251515001 AIR FLOW READINGS 7/6/2015 04/6/2015 04/6/2016 SHORTRIDGE FLOW HOOD AIF FLOW READINGS 7/6/2015 * * TH-720 HYGROMETER/ #TH7200950003 AIR TEMP / HUMIDITY NOT USED 06/03/2015 06/03/2016 PITOT TUBE 18” PRES. READINGS 7/6/2015 N/A N/A PITOT TUBE 24” PRES. READINGS NOT USED N/A N/A PITOT TUBE 36” PRES. READINGS NOT USED N/A N/A PITOT TUBE 48” PRES. READINGS NOT USED NA NA SHIMPO TACHOMETER / #C105B0010 RPM READINGS NOT USED 06/03/2015 06/03/2016 FLUKE 375 / #21290229 VOLT / AMP NOT USED 06/03/2015 06/03/2016 SHORTRIDGE HDM-250/ #W11037 WATER PRES. READINGS 7/6/2015 06/08/2015 06/08/2016 ASCROFT / 0-100 PSI / #DO68332-06 WATER PRES. READINGS NOT USED * * FLUKE 52 II THERMOMETER / 99780167 TEMP. READINGS NOT USED 06/11/2015 06/11/2016 REFRACTOMETER RHA-100 / #RHA- 100 GLYCOL % READINGS 7/6/2015 N/A N/A * CHECKED TO CALIBRATED METER REMARKS: ALL READINGS WITH SHORTRIDGE INSTRUMENTS ARE CORRECTED FOR TEMPERATURE AND ALTITUDE. PAGE: HVAC TAB llc SYSTEM OBSERVATION REPORT DATE: 7/9/2015 PROJECT: VVMC MEDICAL PROFESSIONS BLDG SYSTEM: HVAC ATTN: FALCON PLUMBING AND HEATING PHONE: FAX: SYSTEM OBSERVATION VAV-105 NO ACCESS TO CIRCUIT SETTER EF-1 OPERATING AT 67% OF DESIGN CFM EF-3 NO CFM EF-4 NO CFM EF-5 NO CFM EXHAUST SYSTEM IS PART OF ENTIRE BUILDING POSSIBLY OTHER SYSTEMS OR FLOORS TAKING CFM HVAC TAB llc DATE: 7/3/2015 VAV BOX DESIGN ACTUAL NOTES HTG NO. SIZE ADDRESS COOL MAX COOL MIN HTG COOL MAX. COOL MIN. VAV-101 8 4 415 145 160 433 151 158 VAV-103 6 5 250 70 235 256 69 231 VAV-104 6 6 230 70 130 249 76 141 VAV-105 8 8 305 145 145 302 144 147 VAV-106 8 11 275 145 250 276 154 252 VAV-107 8 10 560 170 340 562 183 341 VAV-109 8 15 300 145 250 297 135 259 VAV-110 6 9 285 70 70 278 66 70 VAV-111 8 16 250 145 145 252 145 143 VAV-112 8 14 250 145 - 258 144 - VAV-113 8 13 300 145 145 307 142 143 VAV-114 8 12 600 180 180 608 192 191 VAV-115 8 7 390 145 145 385 138 139 VAV-116 8 17 365 150 150 398 165 165 VAV TEST SUMMARY PROJECT: VVMC MEDICAL PROFESSIONS BLDG SYSTEM: VAV-101 - VAV-116 PAGE: NOTES: SYSTEM TERMINAL DESIGN INITIAL FINAL NOTES NO TYPE SIZE AK VEL CFM VEL CFM COOL MAX COOL MIN HTG VAV-101 1 CD 24/24 50 91 52 10 15 2 CD 24/24 180 167 183 70 67 3 CD 24/24 185 172 198 71 76 415 430 433 151 158 TOTAL VAV-103 1 CD 24/24 135 61 144 44 132 2 CD 24/24 115 85 112 25 99 250 146 256 69 231 TOTAL VAV-104 1 CD 24/24 105 127 113 26 61 2 CD 24/24 125 126 136 50 80 230 253 249 76 141 TOTAL VAV-105 1 CD 24/24 105 158 104 52 49 2 CD 24/24 200 145 198 92 98 305 303 302 144 147 TOTAL VAV-106 1 CD 24/24 100 127 102 59 91 2 CD 24/24 175 148 174 95 161 275 275 276 154 252 TOTAL VAV-107 1 CD 24/24 170 196 166 53 101 2 CD 24/24 100 129 99 35 61 3 CD 24/24 150 126 160 49 95 4 CD 24/24 140 120 137 46 84 560 571 562 183 341 TOTAL NOTES: HVAC TAB llc DATE: 7/3/2015 AIR TERMINAL TEST REPORT PAGE: PROJECT: VVMC MEDICAL PROFESSIONS BLDG SYSTEM: VAV-101 - VAV-107 SYSTEM TERMINAL DESIGN INITIAL FINAL NOTES NO TYPE SIZE AK VEL CFM VEL CFM COOL MAX COOL MIN HTG VAV-109 1 CD 24/24 150 136 148 68 134 2 CD 24/24 150 154 149 67 125 300 290 297 135 259 TOTAL VAV-110 1 CD 24/24 180 132 175 44 49 2 CD 24/24 105 149 103 22 21 285 281 278 66 70 TOTAL VAV-111 1 CD 24/24 200 163 200 125 120 2 CD 24/24 50 97 52 20 23 250 260 252 145 143 TOTAL VAV-112 1 CD 24/24 50 132 51 21 - 2 CD 24/24 200 125 207 123 - 250 257 258 144 0 TOTAL VAV-113 1 CD 24/24 125 104 125 60 66 2 CD 24/24 125 119 129 62 57 3 CD 24/24 50 89 53 20 20 300 312 307 142 143 TOTAL VAV-114 1 CD 24/24 300 260 302 93 93 2 CD 24/24 300 356 306 99 98 600 616 608 192 191 TOTAL NOTES: HVAC TAB llc DATE: 7/3/2015 AIR TERMINAL TEST REPORT PAGE: PROJECT: VVMC MEDICAL PROFESSIONS BLDG SYSTEM: VAV-109 - VAV-114 SYSTEM TERMINAL DESIGN INITIAL FINAL NOTES NO TYPE SIZE AK VEL CFM VEL CFM COOL MAX COOL MIN HTG VAV-115 1 CD 24/24 50 105 53 10 10 2 CD 24/24 200 155 188 68 68 3 CD 24/24 140 137 144 60 61 390 397 385 138 139 TOTAL VAV-116 1 CD 24/24 80 200 86 30 24 2 CD 24/24 285 190 312 135 141 365 390 398 165 165 TOTAL EF-1 1 ER 23/11 75 50 TOTAL EF-2 2 ER 23/11 75 77 TOTAL EF-3 3 ER 11/11 80 0 TOTAL EF-4 4 ER 23/18 140 0 TOTAL EF-5 5 ER 23/23 140 0 TOTAL NOTES: HVAC TAB llc DATE: 7/3/2015 AIR TERMINAL TEST REPORT PAGE: PROJECT: VVMC MEDICAL PROFESSIONS BLDG SYSTEM: VAV-115 - VAV-116 / EF-1-5 HVAC TAB llc DATE: 7/6/2015 FLOW METER DESIGN MEASURED LOCATION TYPE SIZE DESIGN P DESIGN GPM FINAL P VALVE POSITION % OPEN FINAL GPM VAV-101 MACON MB 075 RL 0.5 14.3 22% 0.5 VAV-103 MACON MB 075 RL 0.6 21.1 23% 0.6 VAV-104 MACON MB 075 RL 0.5 14.0 20% 0.5 VAV-105 MACON MB 075 RL 0.5 NA 20% NA VAV-106 MACON MB 075 RL 0.6 20.7 25% 0.6 VAV-107 MACON MB 075 RL 0.8 37.1 30% 0.8 VAV-109 MACON MB 075 RL 0.6 21.8 27% 0.6 VAV-110 MACON MB 075 RL 0.5 14.1 20% 0.5 VAV-111 MACON MB 075 RL 0.5 14.0 25% 0.5 VAV-112 - - - - - - VAV-113 MACON MB 075 RL 0.5 13.9 28% 0.5 VAV-114 MACON MB 075 RL 0.5 14.1 25% 0.5 VAV-115 MACON MB 075 RL 0.5 14.3 20% 0.5 VAV-116 MACON MB 075 RL 0.5 14.1 27% 0.5 BALANCE VALVE TEST REPORT PROJECT: VVMC MEDICAL PROFESSIONS BLDG PAGE: NOTES: 0% GLYCOL SYSTEM: VAV-101 - VAV-116 PAGE: