HomeMy WebLinkAboutM003.pdfRADIANT HEATING PANEL SCHEDULE PANEL DESIG. MFR. MODEL PANEL SIZE BTU/HR GPM PANEL TUBE FINISH INSULATION REMARKS MATERIAL MATERIAL THICKNESS RP-1 AERO TECH RLFM 24x24 760 .5 0.04" ALUMINUM 1/2" COPPER MATCH CEILING 4" 12/11/2014 16:35 \\CRA-SERVER07\Projects\VVMC\2014-369 MPB TF\Cad\Mech\Mschedules\[M-2014-369.xlsx]S933-2 Term Box HW DUCT PRESSURE CLASSIFICATION SCHEDULE DUCT TYPE PRESSURE CLASS REMARKS MEDIUM PRESSURE SUPPLY AIR DUCT 4" LOW PRESSURE SUPPLY AIR DUCT 2" ALL RETURN AND EXHAUST DUCT 2" 12/12/2014 14:11 \\CRA-SERVER07\Projects\VVMC\2014-369 MPB TF\Cad\Mech\Mschedules\[M-2014-369.xlsx]S891-1 Duct Psr TERMINAL BOX SCHEDULE (HOT WATER HEAT) INTERIOR AIR PRESS COOLING DESIGN CFM HEATING HEATING WATER COIL DATA MODULATING DESIG OR MFR MODEL INLET DROP MAX MAXIMUM MINIMUM DESIGN CFM EAT LAT MBH GPM WATER EWT CONTROL SOUND REMARKS PERIMETER DIA. (IN WC) ELEV FT ELEV FT ELEV FT °F °F P.D. MAX °F VALVE TYPE ATTENUATOR ZONE (IN.) (SEA LEVEL) 8150 8150 8150 (FT WC) VAV-101 PERIMETER PRICE SDV 8 8 0.64 415 145 160 55 90 4.5 0.5 3.00 180 2-WAY NO VAV-103 PERIMETER PRICE SDV 6 6 0.64 250 70 235 55 90 6.6 0.6 3.00 180 2-WAY NO VAV-104 PERIMETER PRICE SDV 6 6 0.64 230 70 130 55 90 3.6 0.5 3.00 180 2-WAY NO VAV-105 PERIMETER PRICE SDV 8 8 0.64 305 145 145 55 90 4.1 0.5 3.00 180 2-WAY NO VAV-106 PERIMETER PRICE SDV 8 8 0.64 250 145 145 55 90 4.1 0.5 3.00 180 2-WAY NO 3 VAV-107 PERIMETER PRICE SDV 8 8 0.64 480 145 340 55 95 10.9 0.8 3.00 180 2-WAY NO VAV-109 PERIMETER PRICE SDV 8 8 0.64 250 145 250 55 90 7.0 0.6 3.00 180 2-WAY NO VAV-110 INTERIOR PRICE SDV 6 6 0.64 285 70 70 55 80 1.4 0.5 3.00 180 2-WAY NO VAV-111 PERIMETER PRICE SDV 8 8 0.64 250 145 145 55 90 4.1 0.5 3.00 180 2-WAY NO VAV-112 INTERIOR PRICE SDV 8 8 0.64 250 145 COOL-ONLY NO VAV-113 INTERIOR PRICE SDV 8 8 0.64 300 145 145 55 80 2.9 0.5 3.00 180 2-WAY NO VAV-114 INTERIOR PRICE SDV 8 8 0.64 600 180 180 55 80 3.6 0.5 3.00 180 2-WAY NO VAV-115 INTERIOR PRICE SDV 8 8 0.64 390 145 145 55 80 2.9 0.5 3.00 180 2-WAY NO VAV-116 INTERIOR PRICE SDV 8 8 0.64 365 150 150 55 80 3.0 0.5 3.00 180 2-WAY NO 1 VAV-201 PERIMETER PRICE SDV 8 8 0.64 580 175 480 55 95 15.3 1.2 3.00 180 2-WAY NO VAV-202 INTERIOR PRICE SDV 8 8 0.64 535 165 165 55 80 3.3 0.5 3.00 180 2-WAY NO VAV-203 INTERIOR PRICE SDV 9 9 0.48 825 250 250 55 80 5.0 0.5 4.00 180 2-WAY NO VAV-204 PERIMETER PRICE SDV 8 8 0.64 560 170 560 55 95 17.9 1.4 3.00 180 2-WAY NO VAV-205 PERIMETER PRICE SDV 6 6 0.64 120 70 120 55 90 3.4 0.5 3.00 180 2-WAY NO VAV-206 PERIMETER PRICE SDV 6 6 0.64 175 70 140 55 90 3.9 0.5 3.00 180 2-WAY NO VAV-207 PERIMETER PRICE SDV 6 6 0.64 150 70 135 55 90 3.8 0.5 3.00 180 2-WAY NO VAV-208 PERIMETER PRICE SDV 8 8 0.64 240 145 240 55 90 6.7 0.6 3.00 180 2-WAY NO VAV-209 INTERIOR PRICE SDV 8 8 0.64 200 145 145 55 80 2.9 0.5 3.00 180 2-WAY NO VAV-210 INTERIOR PRICE SDV 6 6 0.64 100 70 0 COOL-ONLY NO VAV-211 INTERIOR PRICE SDV 8 8 0.64 330 145 145 55 80 2.9 0.5 3.00 180 2-WAY NO VAV-212 PERIMETER PRICE SDV 8 8 0.64 125 70 120 55 90 3.4 0.5 3.00 180 2-WAY NO VAV-301 INTERIOR PRICE SDV 8 8 0.64 440 150 150 55 80 3.0 0.5 3.00 180 2-WAY NO 2 REQUIREMENTS APPLYING TO ALL TERMINAL BOXES: 9,000 3,540 14.7 A. PROVIDE BOX SELECTION TO MEET LAT, DESIGN CFM AND HEATING MBH. FINAL GPM SHALL BE SET DURING BALANCING TO FLOW RATES IN LISTED PRODUCT DATA SUBMITTALS. B. MAXIMUM STATIC PRESSURE IS BASED ON WIDE OPEN UNIT AT MAXIMUM FLOW FOR TERMINAL BOX WITH 2-ROW COIL. C. HEATING WATER SYSTEM CONTAINS [0] [10] [20] [30]% PROPYLENE GLYCOL. D. 2-ROW HEATING COIL CONDITIONS SHOW. 1- & 2-ROW HEATING COILS ACCEPTABLE COMPLIANT WITH MBH, WATER FLOW, AIR & WATER PRESSURE DROP REQUIREMENTS & LIMITATIONS. E. USE OF 3- & 4-ROW COILS MUST BE SPECIFICALLY IDENTIFIED BY THE SUPPLIER & ACCEPTED BY THE ENGINEER FOR EACH LOCATION PROPOSED. F. TERMINAL BOX MAXIMUM AIR FLOW CAPABILITIES: 6"=450 CFM, 8"=800 CFM, 9"=1050 CFM, 10"=1350 CFM, 12"=2000 CFM, 14"=3000 CFM, 16"=4000 CFM & 24"x16"=8000 CFM. G. MINIMUM 2-ROW COILS REQUIRED ON ALL PERIMETER BOXES. REMARKS: 1. THIS BOX WAS PREVIOUSLY M301 ON L3. IT MOVED TO L1 AS A RESULT OF THE XRAY MOVE. 2. THIS IS A NEW BOX ON L3. 3. REUSE OF PREVIOUSLY SCHEDULED BOX. 3/12/2015 P:\VVMC\2014-369 MPB TF\Cad\Mech\Mschedules\[M-2014-369.xlsx]S933-2 Term Box HW PLUMBING FIXTURE & EQUIPMENT SCHEDULE ELECTRICAL FIXTURE FITTINGS ACCESSORY LEED CONNECTIONS SYMBOL REQUIREMENTS FIXTURE NAME MANUFACTURER MODEL TYPE SIZE MANUFACTURER MODEL SUPPLY I.R. / BATTERY GPM WASTE VENT CW HW REMARKS HP OR GPF WC-1 (ADA)WATER CLOSET AMERICAN STANDARD 3043.102 17" RIM HT. FLOOR SET, SIPHON JET 1.6 GPF ELONGATED BOWL SLOAN, ROYAL 111-YO N/A 4" 2" 1" N/A RE: ARCH. DWGS FOR MTG. HT. & LOC. PROVIDE AMERICAN STANDARD 5901.110 TOILET SEAT L-1 (ADA)LAVATORY AMERICAN STANDARD 0356.041 WALL MOUNTED, VITREOUS CHINA 21" X 18" T & S, BRASS B-2711 RE: SPEC - 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. HT. & LOC. S-1 (ADA)1 COMPT . SINK ELKAY LRAD1919 SELF-RIMMING, STAINLESS STEEL 19" X 19" X 6 1/2" T & S, BRASS B-2855 RE:SPEC 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. S-5 (ADA)1 COMPT. SINK ELKAY LRAD1919 SELF-RIMMING, STAINLESS STEEL 19" X 19" X 6 1/2"SPEAKMAN SEF-1800-6WH-LF EYE SAVER RE: SPEC 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. EYE WASH TRIM S-3 (ADA)2 COMPT. SINK ELKAY EG3322 W/ 3-HOLE PUNCH SELF-RIMMING, STAINLESS STEEL 32" X 22" X 8" T & S, BRASS B-2865-04 RE: SPEC - 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. S-4 (ADA)1 COMPT. SINK ELKAY LRAD2521 W/ 4-HOLE PUNCH OFF-CENTER DRAIN SELF-RIMMING, STAINLESS STEEL 25"X 21" X 6 1/2" T & S, BRASS B-2730 RE: SPEC 2" 11/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. S-2 (ADA)2 COMPT. SINK ELKAY LRAD3722 W/ 4-HOLE PUNCH OFF-CENTER DRAIN SELF-RIMMING, STAINLESS STEEL 37"X 22" 6 1/2" T & S, BRASS B-2730 RE: SPEC 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. MSB-1 MOP SERVICE BASIN MUSTEE 63M CORNER INSTALLATION 24"X 24" X10" T & S, BRASS B-0665-BSTP N/A 3" 2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. HT. & LOC. FD-1 FLOOR/ SHOWER DRAIN JAY R. SMITH 2005 CAST IRON DRAIN RE: ROUND OR SQUARE N/A N/A N/A RE: PLANS 2" MIN.5" MINIMUM STRAINER SIZE, ROUND GRATE FS-1 FLOOR SINK JAY R. SMITH 3060 CAST IRON FLOOR SINK W/ BUCKET STRAINER 8" DIA.N/A N/A N/A RE: PLANS 2" MIN.- - ACID RESISTANT ENAMEL COATED, 1/2 GRATE EW-1 EYE/ FACE WASH FIXTURE SPEAKMAN SEF-1800 SINK-MOUNTED, W/ GOOSENECK FAUCET N/A LEONARD TA-300 MIXING VALVE N/A 2" 1 1/2" 1/2" 1/2" RE: ARCH. DWGS FOR MTG. LOC. 1. REFER TO GENERAL SPECIFICATIONS FOR WATER CLOSETS, URINALS, LAVATORIES, SINKS AND MISC. FIXTURE REQUIREMENTS. 2. GRAB BARS BY ARCHITECT. 3. THIS SCHEDULE INCLUDES ITEMS THAT MAY NOT BE INCLUDED IN THE DRAWING DOCUMENTS. 4. PROVIDE TRAP PRIMERS FOR ALL FLOOR DRAINS AND FLOOR SINKS. S440-1 FAN SCHEDULE CFM S.P. VIBRATION APPROX. ARRANGE. DESIG. MFR. MODEL FAN TYPE SERVICE AT IN. W.C. APPROX. MIN. ISOLATOR DRIVE DAMPER THROAT & CONTROL REMARKS 8150' AT 8150' RPM HP TYPE TYPE TYPE DIM. MOUNTING EF-21 GREENHECK SQ-080G INLINE CENTRIFUGAL EXHAUST 150 0.3 1300 1/4 NOTE 1 DIRECT BACK DRAFT 15/12 NOTE 1 NOTE 2 ALL NOTES: 1. HANG FAN FROM STRUCTURE ABOVE. COORD WITH STRUCTURAL. PROVIDE HANGING NEOPRENE ISOLATORS. 2. PROVIDE WALL SWITCH FOR FAN CONTROL. 3. PROVIDE DIRECT DRIVE VARIGREEN/ECM MOTOR. 12/12/2014 14:11 \\CRA-SERVER07\Projects\VVMC\2014-369 MPB TF\Cad\Mech\Mschedules\[M-2014-369.xlsx]S891-1 Duct Psr AIR DEVICE SCHEDULE DESIG. FUNCTION STYLE MFR. MODEL FRAME MODULE MATERIAL FINISH REMARKS STYLE SIZE A CEILING SUPPLY FIXED VANES RECTANGULAR PRICE SCD LAY-IN CEILING 24x24 STEEL WHITE B CEILING RETURN, EXHAUST, TRANSFER MODULAR PERFORATED FACE W/DUCT COLLAR PRICE PDDR LAY-IN CEILING 12x24 & 24x24 STEEL WHITE C CEILING RETURN, EXHAUST, TRANSFER MODULAR PERFORATED FACE W/DUCT COLLAR PRICE PDDR NOTE 2 12x24 & 24x24 STEEL WHITE D SIDEWALL SUPPLY ADJUST VANES, DOUBLE DEFLECTION, 3/4" O.C.PRICE 520 SURFACE SEE PLANS STEEL WHITE FRONT HORIZ & REAR VERTICAL BLADES REMARKS: GENERAL - APPLIES TO ALL AIR DEVICES: MANUAL VOLUME DAMPERS SHALL BE PROVIDED IN DUCTWORK AT THE BRANCH POINT OF THE RUNOUT DUCT OR IN-LINE TO THE AIR DEVICE BY THE CONTRACTOR INSTALLING DUCTWORK. A DAMPER LOCATED AT THE AIR DEVICE SHALL ACCEPTABLE WHEN PERMITTED BY ENGINEER ON A CASE-BY-CASE BASIS OR WHEN THE MANUFACTURER REQUIRES AN INTEGRAL MANUAL VOLUME DAMPER. 1. PROVIDE A PLENUM BOX ON GRILLE FOR CONNECTION OF DUCTWORK. PAINT INSIDE OF PLENUM FLAT BLACK. 2. CORRDINATE LAY-IN CEILING OR SURFACE MOUNT WITH ARCHITECTURAL PLANS. 12/11/2014 16:35 \\CRA-SERVER07\Projects\VVMC\2014-369 MPB TF\Cad\Mech\Mschedules\[M-2014-369.xlsx]S933-2 Term Box HW 13026.06 project number Heery International 555 17th Street, Suite 500 Denver, CO 80202 720.946.0276 VVMC MEDICAL PROFESSIONS BUILDING TENANT FINISH REMODEL 108 SOUTH FRONTAGE ROAD VAIL, CO 81657 CATOR RUMA & ASSOCIATES, CO 896 TABOR STREET LAKEWOOD, CO 80401-4700 303.232.6200 MARTIN/MARTIN, INC. 225 MAIN ST., SUITE C 101, EDWARDS, COLORADO 81632 970.926.6007 consultants/construction managers owner's project number DECEMBER 15, 2014 ISSUE FOR CONSTRUCTION 2' 4' 8' SCALE: This document is the property of Heery International, Inc. and Heery International Inc. retains all rights therein, including copyrights. It may only be used in a manner consistent with Heery International Inc.'s rights while Heery International, Inc. is providing services for the specific project identified or referred to herein or extensions thereto. It may not be used for any other purpose except with the express written agreement of, and compensation to, Heery International Inc. Copyright © 2013 by Heery International, Inc. all rights reserved. WHEN PLOTTED AT FULL SIZE THIS SHEET MEASURES 30"x42" drawn by checked by sheet number key plan sheet title item date date issued for seal/signature 1/4" = 1'-0" M003 MECHANICAL SCHEDULES JDD JDD 04/15/15