HomeMy WebLinkAboutCrespelle_Response_TownOfVail.pdf
Response to comments:
project: Crespelle Pop Up at Gorsuch
regarding: 263 E Gore Creek Food Service Plan Review
date: 01.09.14
Comments by Town of Vail Plans Examiner J Mondragon received via project dox 01.07.12
J Mondragon Comments & Responses
Building
Sheet A100 Architect to submit separated use calculations to determine verify
building construction type
Response SBD: See revised Code Analysis sheet A000 classifying building as Type V B
non-separated per 508.3.2, A-2 governing
Sheet A101 Provide details for all fire walls/ceilings UL listed assemblies
Response SBD: Non-separated per 508.3.2
FS000 Architect of Record to review and stamp these drawings as part of
submittal record
Response SBD: See Attached FS sheet
M100 Address requirement of Type II hood 2012 IMC 507.2 and listing
griddles as commercial cooking appliances
Response Rader Engineering: See revised sheet M100 for addition of exhaust
Note: electrical service size and location revised